Accuracy of non-invasive haemoglobin measurements in patients undergoing transurethral resection of prostate surgery
BACKGROUND AND AIMS: The aim of this study was to evaluate the accuracy of non-invasive haemoglobin (SpHb) compared to laboratory venous haemoglobin (tHb) measurements among patients undergoing elective transurethral resection of prostate (TURP) surgery under spinal anaesthesia. METHODS: In a prospe...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8191187/ https://www.ncbi.nlm.nih.gov/pubmed/34188257 http://dx.doi.org/10.4103/ija.IJA_1067_20 |
_version_ | 1783705826905554944 |
---|---|
author | Selvaraj, Naveen Jain, Gaurav Tripathy, Debendra Kumar Mittal, Ankur Indulekha, Haritha |
author_facet | Selvaraj, Naveen Jain, Gaurav Tripathy, Debendra Kumar Mittal, Ankur Indulekha, Haritha |
author_sort | Selvaraj, Naveen |
collection | PubMed |
description | BACKGROUND AND AIMS: The aim of this study was to evaluate the accuracy of non-invasive haemoglobin (SpHb) compared to laboratory venous haemoglobin (tHb) measurements among patients undergoing elective transurethral resection of prostate (TURP) surgery under spinal anaesthesia. METHODS: In a prospective, observational, outcome-assessor blinded, cohort trial, we enroled 50 American Society of Anesthesiologists physical status (ASA-PS) I-II patients with benign prostatic hyperplasia. The primary outcome included SpHb and tHb measurements performed at four perioperative time-points: just before initiating the fluid preload (T1), and at 30 min (T2), 1 h (T3), and 2 h (T4) after starting the prostate resection, respectively. Statistical tool included intra-class correlation (ICC), Bland-Altman plots, and linear regression analysis. RESULTS: We collected 200 SpHb/tHb data sets from 50 patients. The SpHb had a non-significant negative bias of –0.83 g/dL, –0.43 g/dL, –0.81 g/dL, and –0.46 g/dL, with limits of agreement of 2.6 g/dL to –4.2 g/dL, 2.4 g/dL to –3.3 g/dL, 1.3 g/dL to –2.8 g/dL, and 1.4 g/dL to –2.3 g/dL, for T1 to T4, respectively. The SpHb/tHb pairs correlated significantly (time-dependent increase in ICC from T1 to T4). The SpHb-tHb difference correlated significantly with corresponding serum sodium (T1 to T3), but not with perfusion index. No correlation existed between % change in SpHb-tHb difference (T1 to T4), and intraoperative blood loss or perioperative weight gain. CONCLUSION: The SpHb exhibited a clinically acceptable negative bias compared to tHb during TURP surgery. Although a wide limit of agreement between the SpHb/tHb pairs is a limitation, the real-time SpHb trends can still serve in clinical judgement. |
format | Online Article Text |
id | pubmed-8191187 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-81911872021-06-28 Accuracy of non-invasive haemoglobin measurements in patients undergoing transurethral resection of prostate surgery Selvaraj, Naveen Jain, Gaurav Tripathy, Debendra Kumar Mittal, Ankur Indulekha, Haritha Indian J Anaesth Original Article BACKGROUND AND AIMS: The aim of this study was to evaluate the accuracy of non-invasive haemoglobin (SpHb) compared to laboratory venous haemoglobin (tHb) measurements among patients undergoing elective transurethral resection of prostate (TURP) surgery under spinal anaesthesia. METHODS: In a prospective, observational, outcome-assessor blinded, cohort trial, we enroled 50 American Society of Anesthesiologists physical status (ASA-PS) I-II patients with benign prostatic hyperplasia. The primary outcome included SpHb and tHb measurements performed at four perioperative time-points: just before initiating the fluid preload (T1), and at 30 min (T2), 1 h (T3), and 2 h (T4) after starting the prostate resection, respectively. Statistical tool included intra-class correlation (ICC), Bland-Altman plots, and linear regression analysis. RESULTS: We collected 200 SpHb/tHb data sets from 50 patients. The SpHb had a non-significant negative bias of –0.83 g/dL, –0.43 g/dL, –0.81 g/dL, and –0.46 g/dL, with limits of agreement of 2.6 g/dL to –4.2 g/dL, 2.4 g/dL to –3.3 g/dL, 1.3 g/dL to –2.8 g/dL, and 1.4 g/dL to –2.3 g/dL, for T1 to T4, respectively. The SpHb/tHb pairs correlated significantly (time-dependent increase in ICC from T1 to T4). The SpHb-tHb difference correlated significantly with corresponding serum sodium (T1 to T3), but not with perfusion index. No correlation existed between % change in SpHb-tHb difference (T1 to T4), and intraoperative blood loss or perioperative weight gain. CONCLUSION: The SpHb exhibited a clinically acceptable negative bias compared to tHb during TURP surgery. Although a wide limit of agreement between the SpHb/tHb pairs is a limitation, the real-time SpHb trends can still serve in clinical judgement. Wolters Kluwer - Medknow 2021-05 2021-05-10 /pmc/articles/PMC8191187/ /pubmed/34188257 http://dx.doi.org/10.4103/ija.IJA_1067_20 Text en Copyright: © 2021 Indian Journal of Anaesthesia https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Selvaraj, Naveen Jain, Gaurav Tripathy, Debendra Kumar Mittal, Ankur Indulekha, Haritha Accuracy of non-invasive haemoglobin measurements in patients undergoing transurethral resection of prostate surgery |
title | Accuracy of non-invasive haemoglobin measurements in patients undergoing transurethral resection of prostate surgery |
title_full | Accuracy of non-invasive haemoglobin measurements in patients undergoing transurethral resection of prostate surgery |
title_fullStr | Accuracy of non-invasive haemoglobin measurements in patients undergoing transurethral resection of prostate surgery |
title_full_unstemmed | Accuracy of non-invasive haemoglobin measurements in patients undergoing transurethral resection of prostate surgery |
title_short | Accuracy of non-invasive haemoglobin measurements in patients undergoing transurethral resection of prostate surgery |
title_sort | accuracy of non-invasive haemoglobin measurements in patients undergoing transurethral resection of prostate surgery |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8191187/ https://www.ncbi.nlm.nih.gov/pubmed/34188257 http://dx.doi.org/10.4103/ija.IJA_1067_20 |
work_keys_str_mv | AT selvarajnaveen accuracyofnoninvasivehaemoglobinmeasurementsinpatientsundergoingtransurethralresectionofprostatesurgery AT jaingaurav accuracyofnoninvasivehaemoglobinmeasurementsinpatientsundergoingtransurethralresectionofprostatesurgery AT tripathydebendrakumar accuracyofnoninvasivehaemoglobinmeasurementsinpatientsundergoingtransurethralresectionofprostatesurgery AT mittalankur accuracyofnoninvasivehaemoglobinmeasurementsinpatientsundergoingtransurethralresectionofprostatesurgery AT indulekhaharitha accuracyofnoninvasivehaemoglobinmeasurementsinpatientsundergoingtransurethralresectionofprostatesurgery |