Cargando…

Accuracy of non-invasive haemoglobin measurements in patients undergoing transurethral resection of prostate surgery

BACKGROUND AND AIMS: The aim of this study was to evaluate the accuracy of non-invasive haemoglobin (SpHb) compared to laboratory venous haemoglobin (tHb) measurements among patients undergoing elective transurethral resection of prostate (TURP) surgery under spinal anaesthesia. METHODS: In a prospe...

Descripción completa

Detalles Bibliográficos
Autores principales: Selvaraj, Naveen, Jain, Gaurav, Tripathy, Debendra Kumar, Mittal, Ankur, Indulekha, Haritha
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8191187/
https://www.ncbi.nlm.nih.gov/pubmed/34188257
http://dx.doi.org/10.4103/ija.IJA_1067_20
_version_ 1783705826905554944
author Selvaraj, Naveen
Jain, Gaurav
Tripathy, Debendra Kumar
Mittal, Ankur
Indulekha, Haritha
author_facet Selvaraj, Naveen
Jain, Gaurav
Tripathy, Debendra Kumar
Mittal, Ankur
Indulekha, Haritha
author_sort Selvaraj, Naveen
collection PubMed
description BACKGROUND AND AIMS: The aim of this study was to evaluate the accuracy of non-invasive haemoglobin (SpHb) compared to laboratory venous haemoglobin (tHb) measurements among patients undergoing elective transurethral resection of prostate (TURP) surgery under spinal anaesthesia. METHODS: In a prospective, observational, outcome-assessor blinded, cohort trial, we enroled 50 American Society of Anesthesiologists physical status (ASA-PS) I-II patients with benign prostatic hyperplasia. The primary outcome included SpHb and tHb measurements performed at four perioperative time-points: just before initiating the fluid preload (T1), and at 30 min (T2), 1 h (T3), and 2 h (T4) after starting the prostate resection, respectively. Statistical tool included intra-class correlation (ICC), Bland-Altman plots, and linear regression analysis. RESULTS: We collected 200 SpHb/tHb data sets from 50 patients. The SpHb had a non-significant negative bias of –0.83 g/dL, –0.43 g/dL, –0.81 g/dL, and –0.46 g/dL, with limits of agreement of 2.6 g/dL to –4.2 g/dL, 2.4 g/dL to –3.3 g/dL, 1.3 g/dL to –2.8 g/dL, and 1.4 g/dL to –2.3 g/dL, for T1 to T4, respectively. The SpHb/tHb pairs correlated significantly (time-dependent increase in ICC from T1 to T4). The SpHb-tHb difference correlated significantly with corresponding serum sodium (T1 to T3), but not with perfusion index. No correlation existed between % change in SpHb-tHb difference (T1 to T4), and intraoperative blood loss or perioperative weight gain. CONCLUSION: The SpHb exhibited a clinically acceptable negative bias compared to tHb during TURP surgery. Although a wide limit of agreement between the SpHb/tHb pairs is a limitation, the real-time SpHb trends can still serve in clinical judgement.
format Online
Article
Text
id pubmed-8191187
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-81911872021-06-28 Accuracy of non-invasive haemoglobin measurements in patients undergoing transurethral resection of prostate surgery Selvaraj, Naveen Jain, Gaurav Tripathy, Debendra Kumar Mittal, Ankur Indulekha, Haritha Indian J Anaesth Original Article BACKGROUND AND AIMS: The aim of this study was to evaluate the accuracy of non-invasive haemoglobin (SpHb) compared to laboratory venous haemoglobin (tHb) measurements among patients undergoing elective transurethral resection of prostate (TURP) surgery under spinal anaesthesia. METHODS: In a prospective, observational, outcome-assessor blinded, cohort trial, we enroled 50 American Society of Anesthesiologists physical status (ASA-PS) I-II patients with benign prostatic hyperplasia. The primary outcome included SpHb and tHb measurements performed at four perioperative time-points: just before initiating the fluid preload (T1), and at 30 min (T2), 1 h (T3), and 2 h (T4) after starting the prostate resection, respectively. Statistical tool included intra-class correlation (ICC), Bland-Altman plots, and linear regression analysis. RESULTS: We collected 200 SpHb/tHb data sets from 50 patients. The SpHb had a non-significant negative bias of –0.83 g/dL, –0.43 g/dL, –0.81 g/dL, and –0.46 g/dL, with limits of agreement of 2.6 g/dL to –4.2 g/dL, 2.4 g/dL to –3.3 g/dL, 1.3 g/dL to –2.8 g/dL, and 1.4 g/dL to –2.3 g/dL, for T1 to T4, respectively. The SpHb/tHb pairs correlated significantly (time-dependent increase in ICC from T1 to T4). The SpHb-tHb difference correlated significantly with corresponding serum sodium (T1 to T3), but not with perfusion index. No correlation existed between % change in SpHb-tHb difference (T1 to T4), and intraoperative blood loss or perioperative weight gain. CONCLUSION: The SpHb exhibited a clinically acceptable negative bias compared to tHb during TURP surgery. Although a wide limit of agreement between the SpHb/tHb pairs is a limitation, the real-time SpHb trends can still serve in clinical judgement. Wolters Kluwer - Medknow 2021-05 2021-05-10 /pmc/articles/PMC8191187/ /pubmed/34188257 http://dx.doi.org/10.4103/ija.IJA_1067_20 Text en Copyright: © 2021 Indian Journal of Anaesthesia https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Selvaraj, Naveen
Jain, Gaurav
Tripathy, Debendra Kumar
Mittal, Ankur
Indulekha, Haritha
Accuracy of non-invasive haemoglobin measurements in patients undergoing transurethral resection of prostate surgery
title Accuracy of non-invasive haemoglobin measurements in patients undergoing transurethral resection of prostate surgery
title_full Accuracy of non-invasive haemoglobin measurements in patients undergoing transurethral resection of prostate surgery
title_fullStr Accuracy of non-invasive haemoglobin measurements in patients undergoing transurethral resection of prostate surgery
title_full_unstemmed Accuracy of non-invasive haemoglobin measurements in patients undergoing transurethral resection of prostate surgery
title_short Accuracy of non-invasive haemoglobin measurements in patients undergoing transurethral resection of prostate surgery
title_sort accuracy of non-invasive haemoglobin measurements in patients undergoing transurethral resection of prostate surgery
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8191187/
https://www.ncbi.nlm.nih.gov/pubmed/34188257
http://dx.doi.org/10.4103/ija.IJA_1067_20
work_keys_str_mv AT selvarajnaveen accuracyofnoninvasivehaemoglobinmeasurementsinpatientsundergoingtransurethralresectionofprostatesurgery
AT jaingaurav accuracyofnoninvasivehaemoglobinmeasurementsinpatientsundergoingtransurethralresectionofprostatesurgery
AT tripathydebendrakumar accuracyofnoninvasivehaemoglobinmeasurementsinpatientsundergoingtransurethralresectionofprostatesurgery
AT mittalankur accuracyofnoninvasivehaemoglobinmeasurementsinpatientsundergoingtransurethralresectionofprostatesurgery
AT indulekhaharitha accuracyofnoninvasivehaemoglobinmeasurementsinpatientsundergoingtransurethralresectionofprostatesurgery