Cargando…
Comparative efficacy of supraclavicular versus infraclavicular approach of subclavian vein cannulation under ultrasound guidance: A randomised clinical trial
BACKGROUND AND AIMS: Subclavian vein (SCV) cannulation can be performed using either supraclavicular (SC) or infraclavicular (IC) long-axis approach under ultrasound guidance (USG). However, their relative efficacy remains debatable. The aim of this study was to compare these two approaches in terms...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8191189/ https://www.ncbi.nlm.nih.gov/pubmed/34188258 http://dx.doi.org/10.4103/ija.IJA_1316_20 |
_version_ | 1783705827362734080 |
---|---|
author | Mageshwaran, T Singla, Deepak Agarwal, Ankit Kumar, Ajit Tripathy, Debendra K Agrawal, Sanjay |
author_facet | Mageshwaran, T Singla, Deepak Agarwal, Ankit Kumar, Ajit Tripathy, Debendra K Agrawal, Sanjay |
author_sort | Mageshwaran, T |
collection | PubMed |
description | BACKGROUND AND AIMS: Subclavian vein (SCV) cannulation can be performed using either supraclavicular (SC) or infraclavicular (IC) long-axis approach under ultrasound guidance (USG). However, their relative efficacy remains debatable. The aim of this study was to compare these two approaches in terms of safety, ease, success rate, and record the incidence of complications. METHODS: We studied 90 adult patients distributed into two groups of 45 each. Data regarding the time taken for first venous puncture, the time required for inserting the catheter, the total number of attempts, the incidence of guidewire misplacement, and other mechanical complications were compared using Student's t-test for quantitative data and Chi-square test for qualitative value. RESULTS: Mean puncture time was significantly lesser in group SC than IC (P-value < 0.001). Mean catheter insertion time taken was also significantly less in group SC than IC (P-value = 0.003). The first attempt rate was higher in group SC than IC (P = 0.013). Guidewire misplacement was seen in the IC group, P = 0.001. No pneumothorax, haemothorax, or arterial puncture were noted in our study in any of the groups. CONCLUSION: We conclude that for right-sided SCV cannulation using USG in the long axis, the SC approach is superior to the IC approach in terms of overall ease of cannulation. It was associated with a relatively shorter procedure time, higher success rate in the first attempt, lesser incidence of guidewire misplacement, and other complications. It should be considered as an alternative approach to the IC approach in patients requiring central line insertion. |
format | Online Article Text |
id | pubmed-8191189 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-81911892021-06-28 Comparative efficacy of supraclavicular versus infraclavicular approach of subclavian vein cannulation under ultrasound guidance: A randomised clinical trial Mageshwaran, T Singla, Deepak Agarwal, Ankit Kumar, Ajit Tripathy, Debendra K Agrawal, Sanjay Indian J Anaesth Original Article BACKGROUND AND AIMS: Subclavian vein (SCV) cannulation can be performed using either supraclavicular (SC) or infraclavicular (IC) long-axis approach under ultrasound guidance (USG). However, their relative efficacy remains debatable. The aim of this study was to compare these two approaches in terms of safety, ease, success rate, and record the incidence of complications. METHODS: We studied 90 adult patients distributed into two groups of 45 each. Data regarding the time taken for first venous puncture, the time required for inserting the catheter, the total number of attempts, the incidence of guidewire misplacement, and other mechanical complications were compared using Student's t-test for quantitative data and Chi-square test for qualitative value. RESULTS: Mean puncture time was significantly lesser in group SC than IC (P-value < 0.001). Mean catheter insertion time taken was also significantly less in group SC than IC (P-value = 0.003). The first attempt rate was higher in group SC than IC (P = 0.013). Guidewire misplacement was seen in the IC group, P = 0.001. No pneumothorax, haemothorax, or arterial puncture were noted in our study in any of the groups. CONCLUSION: We conclude that for right-sided SCV cannulation using USG in the long axis, the SC approach is superior to the IC approach in terms of overall ease of cannulation. It was associated with a relatively shorter procedure time, higher success rate in the first attempt, lesser incidence of guidewire misplacement, and other complications. It should be considered as an alternative approach to the IC approach in patients requiring central line insertion. Wolters Kluwer - Medknow 2021-05 2021-05-10 /pmc/articles/PMC8191189/ /pubmed/34188258 http://dx.doi.org/10.4103/ija.IJA_1316_20 Text en Copyright: © 2021 Indian Journal of Anaesthesia https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Mageshwaran, T Singla, Deepak Agarwal, Ankit Kumar, Ajit Tripathy, Debendra K Agrawal, Sanjay Comparative efficacy of supraclavicular versus infraclavicular approach of subclavian vein cannulation under ultrasound guidance: A randomised clinical trial |
title | Comparative efficacy of supraclavicular versus infraclavicular approach of subclavian vein cannulation under ultrasound guidance: A randomised clinical trial |
title_full | Comparative efficacy of supraclavicular versus infraclavicular approach of subclavian vein cannulation under ultrasound guidance: A randomised clinical trial |
title_fullStr | Comparative efficacy of supraclavicular versus infraclavicular approach of subclavian vein cannulation under ultrasound guidance: A randomised clinical trial |
title_full_unstemmed | Comparative efficacy of supraclavicular versus infraclavicular approach of subclavian vein cannulation under ultrasound guidance: A randomised clinical trial |
title_short | Comparative efficacy of supraclavicular versus infraclavicular approach of subclavian vein cannulation under ultrasound guidance: A randomised clinical trial |
title_sort | comparative efficacy of supraclavicular versus infraclavicular approach of subclavian vein cannulation under ultrasound guidance: a randomised clinical trial |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8191189/ https://www.ncbi.nlm.nih.gov/pubmed/34188258 http://dx.doi.org/10.4103/ija.IJA_1316_20 |
work_keys_str_mv | AT mageshwarant comparativeefficacyofsupraclavicularversusinfraclavicularapproachofsubclavianveincannulationunderultrasoundguidancearandomisedclinicaltrial AT singladeepak comparativeefficacyofsupraclavicularversusinfraclavicularapproachofsubclavianveincannulationunderultrasoundguidancearandomisedclinicaltrial AT agarwalankit comparativeefficacyofsupraclavicularversusinfraclavicularapproachofsubclavianveincannulationunderultrasoundguidancearandomisedclinicaltrial AT kumarajit comparativeefficacyofsupraclavicularversusinfraclavicularapproachofsubclavianveincannulationunderultrasoundguidancearandomisedclinicaltrial AT tripathydebendrak comparativeefficacyofsupraclavicularversusinfraclavicularapproachofsubclavianveincannulationunderultrasoundguidancearandomisedclinicaltrial AT agrawalsanjay comparativeefficacyofsupraclavicularversusinfraclavicularapproachofsubclavianveincannulationunderultrasoundguidancearandomisedclinicaltrial |