Cargando…
Factors Responsible for Non-Diagnostic Cytology on Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules
Introduction Fine-needle aspiration (FNA) is a well-recognized procedure for the diagnosis of thyroid nodules, with the advantage of being safe and inexpensive. Fine-needle aspiration cytology (FNAC) is mainly performed for nodules showing suspicious sonographic features that may require thyroidecto...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Cureus
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8191422/ https://www.ncbi.nlm.nih.gov/pubmed/34123652 http://dx.doi.org/10.7759/cureus.14955 |
_version_ | 1783705865532997632 |
---|---|
author | Asad Ullah, Muhammad Iqbal, Junaid Ahmed, Muhammad Saad Darira, Jaideep Lutfi, Irfan Hamid, Kamran Ali, Muhammad |
author_facet | Asad Ullah, Muhammad Iqbal, Junaid Ahmed, Muhammad Saad Darira, Jaideep Lutfi, Irfan Hamid, Kamran Ali, Muhammad |
author_sort | Asad Ullah, Muhammad |
collection | PubMed |
description | Introduction Fine-needle aspiration (FNA) is a well-recognized procedure for the diagnosis of thyroid nodules, with the advantage of being safe and inexpensive. Fine-needle aspiration cytology (FNAC) is mainly performed for nodules showing suspicious sonographic features that may require thyroidectomy. Even when FNAC is performed under sonographic guidance, the cytological specimen obtained may be inadequate, leading to a non-diagnostic outcome. The aim of this study is to determine the sonographic and technical factors influencing the outcome of FNAC. Material and methods This cross-sectional study was conducted prospectively at the radiology department, Dr. Ziauddin Hospital, Karachi, from January 1, 2019, to December 31, 2020. This study was approved by the Ethical Review Committee (ERC) of Ziauddin University. All the patients undergoing ultrasound (US)-guided FNAC of thyroid nodules were included. Patients with a history of previous thyroid surgery, very large thyroid lesions (>5 cm), and those with adjacent soft tissue pathology obscuring the assessment of thyroid nodules were excluded from this study. Result Out of 176 nodules studied, 14 were non-diagnostic and 162 were diagnostic. A 22G needle was used in most of the patients, i.e. 102 (57.3%), which demonstrated no relationship with the non-diagnostic results. According to Bethesda, 136 (77.3%) patients were benign, 22 (12.5%) had lesions with atypia/follicular lesions of undetermined significance, 14 (8%) were non-diagnostic and four (2.3%) were suspicious for malignancy. A subset, including 76 nodules, was categorized according to Thyroid Imaging Reporting and Data System (TIRADS) as follows: 28 (36.8%) nodules were moderately suspicious, 24 (31.6%) were mildly suspicious, 20 (26.3%) were not suspicious, and four (5.3%) nodules were benign. It was also observed that none of the hypoechoic nodules yielded non-diagnostic cytology. Conclusion This study concludes that radiologists must be aware of the technical details, cytologic preparation, and procedure-related complications associated with US-guided FNA to optimize patient care and the diagnostic outcome. |
format | Online Article Text |
id | pubmed-8191422 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Cureus |
record_format | MEDLINE/PubMed |
spelling | pubmed-81914222021-06-10 Factors Responsible for Non-Diagnostic Cytology on Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules Asad Ullah, Muhammad Iqbal, Junaid Ahmed, Muhammad Saad Darira, Jaideep Lutfi, Irfan Hamid, Kamran Ali, Muhammad Cureus Radiology Introduction Fine-needle aspiration (FNA) is a well-recognized procedure for the diagnosis of thyroid nodules, with the advantage of being safe and inexpensive. Fine-needle aspiration cytology (FNAC) is mainly performed for nodules showing suspicious sonographic features that may require thyroidectomy. Even when FNAC is performed under sonographic guidance, the cytological specimen obtained may be inadequate, leading to a non-diagnostic outcome. The aim of this study is to determine the sonographic and technical factors influencing the outcome of FNAC. Material and methods This cross-sectional study was conducted prospectively at the radiology department, Dr. Ziauddin Hospital, Karachi, from January 1, 2019, to December 31, 2020. This study was approved by the Ethical Review Committee (ERC) of Ziauddin University. All the patients undergoing ultrasound (US)-guided FNAC of thyroid nodules were included. Patients with a history of previous thyroid surgery, very large thyroid lesions (>5 cm), and those with adjacent soft tissue pathology obscuring the assessment of thyroid nodules were excluded from this study. Result Out of 176 nodules studied, 14 were non-diagnostic and 162 were diagnostic. A 22G needle was used in most of the patients, i.e. 102 (57.3%), which demonstrated no relationship with the non-diagnostic results. According to Bethesda, 136 (77.3%) patients were benign, 22 (12.5%) had lesions with atypia/follicular lesions of undetermined significance, 14 (8%) were non-diagnostic and four (2.3%) were suspicious for malignancy. A subset, including 76 nodules, was categorized according to Thyroid Imaging Reporting and Data System (TIRADS) as follows: 28 (36.8%) nodules were moderately suspicious, 24 (31.6%) were mildly suspicious, 20 (26.3%) were not suspicious, and four (5.3%) nodules were benign. It was also observed that none of the hypoechoic nodules yielded non-diagnostic cytology. Conclusion This study concludes that radiologists must be aware of the technical details, cytologic preparation, and procedure-related complications associated with US-guided FNA to optimize patient care and the diagnostic outcome. Cureus 2021-05-11 /pmc/articles/PMC8191422/ /pubmed/34123652 http://dx.doi.org/10.7759/cureus.14955 Text en Copyright © 2021, Asad Ullah et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Radiology Asad Ullah, Muhammad Iqbal, Junaid Ahmed, Muhammad Saad Darira, Jaideep Lutfi, Irfan Hamid, Kamran Ali, Muhammad Factors Responsible for Non-Diagnostic Cytology on Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules |
title | Factors Responsible for Non-Diagnostic Cytology on Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules |
title_full | Factors Responsible for Non-Diagnostic Cytology on Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules |
title_fullStr | Factors Responsible for Non-Diagnostic Cytology on Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules |
title_full_unstemmed | Factors Responsible for Non-Diagnostic Cytology on Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules |
title_short | Factors Responsible for Non-Diagnostic Cytology on Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules |
title_sort | factors responsible for non-diagnostic cytology on ultrasound-guided fine-needle aspiration of thyroid nodules |
topic | Radiology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8191422/ https://www.ncbi.nlm.nih.gov/pubmed/34123652 http://dx.doi.org/10.7759/cureus.14955 |
work_keys_str_mv | AT asadullahmuhammad factorsresponsiblefornondiagnosticcytologyonultrasoundguidedfineneedleaspirationofthyroidnodules AT iqbaljunaid factorsresponsiblefornondiagnosticcytologyonultrasoundguidedfineneedleaspirationofthyroidnodules AT ahmedmuhammadsaad factorsresponsiblefornondiagnosticcytologyonultrasoundguidedfineneedleaspirationofthyroidnodules AT darirajaideep factorsresponsiblefornondiagnosticcytologyonultrasoundguidedfineneedleaspirationofthyroidnodules AT lutfiirfan factorsresponsiblefornondiagnosticcytologyonultrasoundguidedfineneedleaspirationofthyroidnodules AT hamidkamran factorsresponsiblefornondiagnosticcytologyonultrasoundguidedfineneedleaspirationofthyroidnodules AT alimuhammad factorsresponsiblefornondiagnosticcytologyonultrasoundguidedfineneedleaspirationofthyroidnodules |