Cargando…

GAPS-EUS: a new and reliable tool for the assessment of basic skills and performance in EUS among endosonography trainees

OBJECTIVE: Endosonography (EUS) is a useful but complex diagnostic modality which requires advanced endoscopy training and guidance by a supervisor. Since learning curves vary among individuals, assessment of the actual competence among EUS trainees is important. DESIGN/METHODS: We designed a novel...

Descripción completa

Detalles Bibliográficos
Autores principales: Hedenström, Per, Marasco, Giovanni, Eusebi, Leonardo Henry, Lindkvist, Bjorn, Sadik, Riadh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8191616/
https://www.ncbi.nlm.nih.gov/pubmed/34108134
http://dx.doi.org/10.1136/bmjgast-2021-000660
_version_ 1783705900422266880
author Hedenström, Per
Marasco, Giovanni
Eusebi, Leonardo Henry
Lindkvist, Bjorn
Sadik, Riadh
author_facet Hedenström, Per
Marasco, Giovanni
Eusebi, Leonardo Henry
Lindkvist, Bjorn
Sadik, Riadh
author_sort Hedenström, Per
collection PubMed
description OBJECTIVE: Endosonography (EUS) is a useful but complex diagnostic modality which requires advanced endoscopy training and guidance by a supervisor. Since learning curves vary among individuals, assessment of the actual competence among EUS trainees is important. DESIGN/METHODS: We designed a novel assessment tool entitled Global Assessment of Performance and Skills in EUS (GAPS-EUS) for assessing skills among EUS trainees. Five quality indicators were marked on a five-grade scale by the supervisor (Observer Score) and by the trainee (Trainee Score). Trainees were included in two high-volume centres (Gothenburg, Sweden, and Bologna, Italy). Outcomes were feasibility, patient safety, reliability, and validity of GAPS-EUS in trainee-performed EUS procedures. RESULTS: Twenty-two EUS-trainees were assessed in a total of 157 EUS procedures with a completion rate of 157/157 (100 %) and a patient adverse event rate of 2/157 (1.3 %; gastroenteritis n=1, fever n=1). GAPS-EUS showed a high measurement reliability (Cronbach’s alpha coefficient=0.87) and a high inter-rater reliability comparing the supervisor and the trainee (r=0.83, r(2)=0.69, p<0.001). The construct of GAPS-EUS was verified by comparing low-level and high-level performance procedures and the content validity by recording that the EUS-FNA manoeuvre resulted in a lower score than other aspects of EUS 3.07 (95% CI 2.91 to 3.23) vs 3.51 (95% CI 3.37 to 3.65) (p<0.001). External validity was confirmed via similar findings in both centres. CONCLUSION: GAPS-EUS is an easy-to-use and reliable tool with a recorded high validity for the assessment of competence among trainees in EUS. It can be recommended to centres involved in the education of future endosonographers. TRIAL REGISTRATION NUMBER: NCT02455570.
format Online
Article
Text
id pubmed-8191616
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-81916162021-06-25 GAPS-EUS: a new and reliable tool for the assessment of basic skills and performance in EUS among endosonography trainees Hedenström, Per Marasco, Giovanni Eusebi, Leonardo Henry Lindkvist, Bjorn Sadik, Riadh BMJ Open Gastroenterol Endoscopy OBJECTIVE: Endosonography (EUS) is a useful but complex diagnostic modality which requires advanced endoscopy training and guidance by a supervisor. Since learning curves vary among individuals, assessment of the actual competence among EUS trainees is important. DESIGN/METHODS: We designed a novel assessment tool entitled Global Assessment of Performance and Skills in EUS (GAPS-EUS) for assessing skills among EUS trainees. Five quality indicators were marked on a five-grade scale by the supervisor (Observer Score) and by the trainee (Trainee Score). Trainees were included in two high-volume centres (Gothenburg, Sweden, and Bologna, Italy). Outcomes were feasibility, patient safety, reliability, and validity of GAPS-EUS in trainee-performed EUS procedures. RESULTS: Twenty-two EUS-trainees were assessed in a total of 157 EUS procedures with a completion rate of 157/157 (100 %) and a patient adverse event rate of 2/157 (1.3 %; gastroenteritis n=1, fever n=1). GAPS-EUS showed a high measurement reliability (Cronbach’s alpha coefficient=0.87) and a high inter-rater reliability comparing the supervisor and the trainee (r=0.83, r(2)=0.69, p<0.001). The construct of GAPS-EUS was verified by comparing low-level and high-level performance procedures and the content validity by recording that the EUS-FNA manoeuvre resulted in a lower score than other aspects of EUS 3.07 (95% CI 2.91 to 3.23) vs 3.51 (95% CI 3.37 to 3.65) (p<0.001). External validity was confirmed via similar findings in both centres. CONCLUSION: GAPS-EUS is an easy-to-use and reliable tool with a recorded high validity for the assessment of competence among trainees in EUS. It can be recommended to centres involved in the education of future endosonographers. TRIAL REGISTRATION NUMBER: NCT02455570. BMJ Publishing Group 2021-06-09 /pmc/articles/PMC8191616/ /pubmed/34108134 http://dx.doi.org/10.1136/bmjgast-2021-000660 Text en © Author(s) (or their employer(s)) 2022. Re-use permitted under CC BY. Published by BMJ. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution 4.0 Unported (CC BY 4.0) license, which permits others to copy, redistribute, remix, transform and build upon this work for any purpose, provided the original work is properly cited, a link to the licence is given, and indication of whether changes were made. See: https://creativecommons.org/licenses/by/4.0/.
spellingShingle Endoscopy
Hedenström, Per
Marasco, Giovanni
Eusebi, Leonardo Henry
Lindkvist, Bjorn
Sadik, Riadh
GAPS-EUS: a new and reliable tool for the assessment of basic skills and performance in EUS among endosonography trainees
title GAPS-EUS: a new and reliable tool for the assessment of basic skills and performance in EUS among endosonography trainees
title_full GAPS-EUS: a new and reliable tool for the assessment of basic skills and performance in EUS among endosonography trainees
title_fullStr GAPS-EUS: a new and reliable tool for the assessment of basic skills and performance in EUS among endosonography trainees
title_full_unstemmed GAPS-EUS: a new and reliable tool for the assessment of basic skills and performance in EUS among endosonography trainees
title_short GAPS-EUS: a new and reliable tool for the assessment of basic skills and performance in EUS among endosonography trainees
title_sort gaps-eus: a new and reliable tool for the assessment of basic skills and performance in eus among endosonography trainees
topic Endoscopy
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8191616/
https://www.ncbi.nlm.nih.gov/pubmed/34108134
http://dx.doi.org/10.1136/bmjgast-2021-000660
work_keys_str_mv AT hedenstromper gapseusanewandreliabletoolfortheassessmentofbasicskillsandperformanceineusamongendosonographytrainees
AT marascogiovanni gapseusanewandreliabletoolfortheassessmentofbasicskillsandperformanceineusamongendosonographytrainees
AT eusebileonardohenry gapseusanewandreliabletoolfortheassessmentofbasicskillsandperformanceineusamongendosonographytrainees
AT lindkvistbjorn gapseusanewandreliabletoolfortheassessmentofbasicskillsandperformanceineusamongendosonographytrainees
AT sadikriadh gapseusanewandreliabletoolfortheassessmentofbasicskillsandperformanceineusamongendosonographytrainees