Cargando…

Adverse Events due to Lack of Precision in Total Hip Arthroplasty: The Potential of Provocation-Based CT for Diagnosis of Implant Loosening

Adverse events in total hip replacement (THR) may have several origins, one being lack of precision in diagnosis and/or during surgery. This study describes the pattern and frequency of avoidable injuries in THR and the potential value of a new tool for early diagnosis of implant loosening. This ret...

Descripción completa

Detalles Bibliográficos
Autores principales: Sandberg, Olof, Olivecrona, Henrik, Gustafson, Pelle
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8192178/
https://www.ncbi.nlm.nih.gov/pubmed/34121950
http://dx.doi.org/10.1155/2021/8836687
_version_ 1783706004044644352
author Sandberg, Olof
Olivecrona, Henrik
Gustafson, Pelle
author_facet Sandberg, Olof
Olivecrona, Henrik
Gustafson, Pelle
author_sort Sandberg, Olof
collection PubMed
description Adverse events in total hip replacement (THR) may have several origins, one being lack of precision in diagnosis and/or during surgery. This study describes the pattern and frequency of avoidable injuries in THR and the potential value of a new tool for early diagnosis of implant loosening. This retrospective study was based on all (n = 1 456) settled claims regarding THR in the Swedish National Patient Insurance database from 2010 to 2017. The claims and medical records were analyzed for root causes, with special focus on adverse events where lack of precision could be the cause. In a second stage, we assessed in 10 patients (20 implants) the diagnostic precision of a new software tool based on provocation-CT. These were all patients where the implant loosening diagnosis was deemed as inconclusive after a first plain X-ray. The findings from the provocation-CT and plain X-ray were compared to the surgical findings at revision. While 3 of 20 implants were correctly diagnosed with plain X-ray, for dynamic CT, this number was 14 of 20 implants. The retrospective study showed that the most common types of injuries were infections (34%), nerve injury (29%), mechanical problems (14.5%), dislocation (6%), and miscellaneous complications (16.5%). Of the patients with mechanical complications, one-third had aseptic implant loosening. Statement of clinical significance: we estimated that almost 200 patients in our registry study had mechanical complications after THR, mainly implant loosening. A third of these could potentially have been diagnosed and treated if CT examination with a dedicated image analysis tool to assess implant loosening after THR had been available.
format Online
Article
Text
id pubmed-8192178
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-81921782021-06-11 Adverse Events due to Lack of Precision in Total Hip Arthroplasty: The Potential of Provocation-Based CT for Diagnosis of Implant Loosening Sandberg, Olof Olivecrona, Henrik Gustafson, Pelle ScientificWorldJournal Research Article Adverse events in total hip replacement (THR) may have several origins, one being lack of precision in diagnosis and/or during surgery. This study describes the pattern and frequency of avoidable injuries in THR and the potential value of a new tool for early diagnosis of implant loosening. This retrospective study was based on all (n = 1 456) settled claims regarding THR in the Swedish National Patient Insurance database from 2010 to 2017. The claims and medical records were analyzed for root causes, with special focus on adverse events where lack of precision could be the cause. In a second stage, we assessed in 10 patients (20 implants) the diagnostic precision of a new software tool based on provocation-CT. These were all patients where the implant loosening diagnosis was deemed as inconclusive after a first plain X-ray. The findings from the provocation-CT and plain X-ray were compared to the surgical findings at revision. While 3 of 20 implants were correctly diagnosed with plain X-ray, for dynamic CT, this number was 14 of 20 implants. The retrospective study showed that the most common types of injuries were infections (34%), nerve injury (29%), mechanical problems (14.5%), dislocation (6%), and miscellaneous complications (16.5%). Of the patients with mechanical complications, one-third had aseptic implant loosening. Statement of clinical significance: we estimated that almost 200 patients in our registry study had mechanical complications after THR, mainly implant loosening. A third of these could potentially have been diagnosed and treated if CT examination with a dedicated image analysis tool to assess implant loosening after THR had been available. Hindawi 2021-06-02 /pmc/articles/PMC8192178/ /pubmed/34121950 http://dx.doi.org/10.1155/2021/8836687 Text en Copyright © 2021 Olof Sandberg et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Sandberg, Olof
Olivecrona, Henrik
Gustafson, Pelle
Adverse Events due to Lack of Precision in Total Hip Arthroplasty: The Potential of Provocation-Based CT for Diagnosis of Implant Loosening
title Adverse Events due to Lack of Precision in Total Hip Arthroplasty: The Potential of Provocation-Based CT for Diagnosis of Implant Loosening
title_full Adverse Events due to Lack of Precision in Total Hip Arthroplasty: The Potential of Provocation-Based CT for Diagnosis of Implant Loosening
title_fullStr Adverse Events due to Lack of Precision in Total Hip Arthroplasty: The Potential of Provocation-Based CT for Diagnosis of Implant Loosening
title_full_unstemmed Adverse Events due to Lack of Precision in Total Hip Arthroplasty: The Potential of Provocation-Based CT for Diagnosis of Implant Loosening
title_short Adverse Events due to Lack of Precision in Total Hip Arthroplasty: The Potential of Provocation-Based CT for Diagnosis of Implant Loosening
title_sort adverse events due to lack of precision in total hip arthroplasty: the potential of provocation-based ct for diagnosis of implant loosening
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8192178/
https://www.ncbi.nlm.nih.gov/pubmed/34121950
http://dx.doi.org/10.1155/2021/8836687
work_keys_str_mv AT sandbergolof adverseeventsduetolackofprecisionintotalhiparthroplastythepotentialofprovocationbasedctfordiagnosisofimplantloosening
AT olivecronahenrik adverseeventsduetolackofprecisionintotalhiparthroplastythepotentialofprovocationbasedctfordiagnosisofimplantloosening
AT gustafsonpelle adverseeventsduetolackofprecisionintotalhiparthroplastythepotentialofprovocationbasedctfordiagnosisofimplantloosening