Modified application of distal medial tibial locking plate as an alternative for fixation of an extraarticular distal-third diaphyseal humerus fracture

INTRODUCTION: Surgical management of Extraarticular Distal-third diaphyseal Humerus Fracture (EADHF) poses a dilemma in terms of surgical approach, implant selection and position of the implant due to the availability of various pre-contoured implants and plate configurations. Various studies have d...

Descripción completa

Detalles Bibliográficos
Autores principales: Thorat, Babaji, Singh, Avtar, Vohra, Rajeev, Arshad, Mohammad, Mavani, Ravi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8192697/
https://www.ncbi.nlm.nih.gov/pubmed/34150977
http://dx.doi.org/10.1016/j.tcr.2021.100420
_version_ 1783706089030680576
author Thorat, Babaji
Singh, Avtar
Vohra, Rajeev
Arshad, Mohammad
Mavani, Ravi
author_facet Thorat, Babaji
Singh, Avtar
Vohra, Rajeev
Arshad, Mohammad
Mavani, Ravi
author_sort Thorat, Babaji
collection PubMed
description INTRODUCTION: Surgical management of Extraarticular Distal-third diaphyseal Humerus Fracture (EADHF) poses a dilemma in terms of surgical approach, implant selection and position of the implant due to the availability of various pre-contoured implants and plate configurations. Various studies have described a modified application of anatomic locking plates as a satisfactory method of fixation in the surgical management of EADHF. CASE PRESENTATION: This report discusses the modified application of anatomic Distal Medial Tibial locking Plate (DMTP) as an alternative strategy in fixation of an acute extraarticular distal-third diaphyseal fracture of the humerus in a 45-years-old female patient. Bony union was achieved successfully without any malalignment and the patient showed a full recovery with an excellent clinical and outcome at 2-years follow-up. CONCLUSION: In EADHF, the use of 3.5 mm DMTP is advantageous as it offers rigid fixation by insertion of more number of 3.5 mm locking bicortical screws and stability in both columns. This promotes biological fracture healing, low rate of complication, early return to work with improvement in clinical function. Therefore, we recommend that pre-contoured 3.5 mm DMTP can be successfully used as an alternative fixation choice for the treatment of EADHF.
format Online
Article
Text
id pubmed-8192697
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-81926972021-06-17 Modified application of distal medial tibial locking plate as an alternative for fixation of an extraarticular distal-third diaphyseal humerus fracture Thorat, Babaji Singh, Avtar Vohra, Rajeev Arshad, Mohammad Mavani, Ravi Trauma Case Rep Case Report INTRODUCTION: Surgical management of Extraarticular Distal-third diaphyseal Humerus Fracture (EADHF) poses a dilemma in terms of surgical approach, implant selection and position of the implant due to the availability of various pre-contoured implants and plate configurations. Various studies have described a modified application of anatomic locking plates as a satisfactory method of fixation in the surgical management of EADHF. CASE PRESENTATION: This report discusses the modified application of anatomic Distal Medial Tibial locking Plate (DMTP) as an alternative strategy in fixation of an acute extraarticular distal-third diaphyseal fracture of the humerus in a 45-years-old female patient. Bony union was achieved successfully without any malalignment and the patient showed a full recovery with an excellent clinical and outcome at 2-years follow-up. CONCLUSION: In EADHF, the use of 3.5 mm DMTP is advantageous as it offers rigid fixation by insertion of more number of 3.5 mm locking bicortical screws and stability in both columns. This promotes biological fracture healing, low rate of complication, early return to work with improvement in clinical function. Therefore, we recommend that pre-contoured 3.5 mm DMTP can be successfully used as an alternative fixation choice for the treatment of EADHF. Elsevier 2021-02-10 /pmc/articles/PMC8192697/ /pubmed/34150977 http://dx.doi.org/10.1016/j.tcr.2021.100420 Text en © 2021 Published by Elsevier Ltd. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Thorat, Babaji
Singh, Avtar
Vohra, Rajeev
Arshad, Mohammad
Mavani, Ravi
Modified application of distal medial tibial locking plate as an alternative for fixation of an extraarticular distal-third diaphyseal humerus fracture
title Modified application of distal medial tibial locking plate as an alternative for fixation of an extraarticular distal-third diaphyseal humerus fracture
title_full Modified application of distal medial tibial locking plate as an alternative for fixation of an extraarticular distal-third diaphyseal humerus fracture
title_fullStr Modified application of distal medial tibial locking plate as an alternative for fixation of an extraarticular distal-third diaphyseal humerus fracture
title_full_unstemmed Modified application of distal medial tibial locking plate as an alternative for fixation of an extraarticular distal-third diaphyseal humerus fracture
title_short Modified application of distal medial tibial locking plate as an alternative for fixation of an extraarticular distal-third diaphyseal humerus fracture
title_sort modified application of distal medial tibial locking plate as an alternative for fixation of an extraarticular distal-third diaphyseal humerus fracture
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8192697/
https://www.ncbi.nlm.nih.gov/pubmed/34150977
http://dx.doi.org/10.1016/j.tcr.2021.100420
work_keys_str_mv AT thoratbabaji modifiedapplicationofdistalmedialtibiallockingplateasanalternativeforfixationofanextraarticulardistalthirddiaphysealhumerusfracture
AT singhavtar modifiedapplicationofdistalmedialtibiallockingplateasanalternativeforfixationofanextraarticulardistalthirddiaphysealhumerusfracture
AT vohrarajeev modifiedapplicationofdistalmedialtibiallockingplateasanalternativeforfixationofanextraarticulardistalthirddiaphysealhumerusfracture
AT arshadmohammad modifiedapplicationofdistalmedialtibiallockingplateasanalternativeforfixationofanextraarticulardistalthirddiaphysealhumerusfracture
AT mavaniravi modifiedapplicationofdistalmedialtibiallockingplateasanalternativeforfixationofanextraarticulardistalthirddiaphysealhumerusfracture