Cargando…
Measurements of thermophysical properties of solid and liquid NIST SRM 316L stainless steel
In this work, we perform high accuracy measurements of thermophysical properties for the National Institute of Standards and Technology standard reference material for 316L stainless steel. As these properties can be sensitive to small changes in elemental composition even within the allowed toleran...
Autores principales: | Pichler, Peter, Simonds, Brian J., Sowards, Jeffrey W., Pottlacher, Gernot |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8193647/ https://www.ncbi.nlm.nih.gov/pubmed/34121767 http://dx.doi.org/10.1007/s10853-019-04261-6 |
Ejemplares similares
-
Re-Analysis of the Uncertainty of the 0.895 µm Diameter (NIST SRM(®) 1690) and the 0.269 µm Diameter (NIST SRM(®) 1691) Sphere Standards
por: Mulholland, G. W.
Publicado: (2005) -
Effect of Initial Surface Scratches on the Cavitation Erosion Behavior of 316L Stainless Steel Substrates and 316L Stainless Steel Coatings
por: Lu, Pengfei, et al.
Publicado: (2023) -
Fatigue Behavior of Additively Manufactured Stainless Steel 316L
por: Avanzini, Andrea
Publicado: (2022) -
Effects of Titanium-Implanted Dose on the Tribological Properties of 316L Stainless Steel
por: Wang, Wei, et al.
Publicado: (2021) -
Investigation of the Properties of 316L Stainless Steel after AM and Heat Treatment
por: Petroušek, Patrik, et al.