A wearable real-time telemonitoring electrocardiogram device compared with traditional Holter monitoring
Arrhythmias are very common in the healthy populations as well as patients with cardiovascular diseases. Among them, atrial fibrillation (AF) and malignant ventricular arrhythmias are usually associated with some clinical events. Early diagnosis of arrhythmias, particularly AF and ventricular arrhyt...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Editorial Department of Journal of Biomedical Research
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8193711/ https://www.ncbi.nlm.nih.gov/pubmed/33495426 http://dx.doi.org/10.7555/JBR.34.20200074 |
_version_ | 1783706282542235648 |
---|---|
author | Shen, Qin Li, Jianqing Cui, Chang Wang, Xingyao Gao, Hongxiang Liu, Chengyu Chen, Minglong |
author_facet | Shen, Qin Li, Jianqing Cui, Chang Wang, Xingyao Gao, Hongxiang Liu, Chengyu Chen, Minglong |
author_sort | Shen, Qin |
collection | PubMed |
description | Arrhythmias are very common in the healthy populations as well as patients with cardiovascular diseases. Among them, atrial fibrillation (AF) and malignant ventricular arrhythmias are usually associated with some clinical events. Early diagnosis of arrhythmias, particularly AF and ventricular arrhythmias, is very important for the treatment and prognosis of patients. Holter is a gold standard commonly recommended for noninvasive detection of paroxysmal arrhythmia. However, it has some shortcomings such as fixed detection timings, delayed report and inability of remote real-time detection. To deal with such problems, we designed and applied a new wearable 72-hour triple-lead H3-electrocardiogram (ECG) device with a remote cloud-based ECG platform and an expert-supporting system. In this study, 31 patients were recruited and 24-hour synchronous ECG data by H3-ECG and Holter were recorded. In the H3-ECG group, ECG signals were transmitted using remote real-time modes, and confirmed reports were made by doctors in the remote expert-supporting system, while the traditional modes and detection systems were used in the Holter group. The results showed no significant differences between the two groups in 24-hour total heart rate (HR), averaged HR, maximum HR, minimum HR, premature atrial complexes (PACs) and premature ventricular complexes (PVCs) (P>0.05). The sensitivity and specificity of capture and remote automatic cardiac events detection of PACs, PVCs, and AF by H3-ECG were 93% and 99%, 98% and 99%, 94% and 98%, respectively. Therefore, the long-term limb triple-lead H3-ECG device can be utilized for domiciliary ECG self-monitoring and remote management of patients with common arrhythmia under medical supervision. |
format | Online Article Text |
id | pubmed-8193711 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Editorial Department of Journal of Biomedical Research |
record_format | MEDLINE/PubMed |
spelling | pubmed-81937112021-08-16 A wearable real-time telemonitoring electrocardiogram device compared with traditional Holter monitoring Shen, Qin Li, Jianqing Cui, Chang Wang, Xingyao Gao, Hongxiang Liu, Chengyu Chen, Minglong J Biomed Res Original Article Arrhythmias are very common in the healthy populations as well as patients with cardiovascular diseases. Among them, atrial fibrillation (AF) and malignant ventricular arrhythmias are usually associated with some clinical events. Early diagnosis of arrhythmias, particularly AF and ventricular arrhythmias, is very important for the treatment and prognosis of patients. Holter is a gold standard commonly recommended for noninvasive detection of paroxysmal arrhythmia. However, it has some shortcomings such as fixed detection timings, delayed report and inability of remote real-time detection. To deal with such problems, we designed and applied a new wearable 72-hour triple-lead H3-electrocardiogram (ECG) device with a remote cloud-based ECG platform and an expert-supporting system. In this study, 31 patients were recruited and 24-hour synchronous ECG data by H3-ECG and Holter were recorded. In the H3-ECG group, ECG signals were transmitted using remote real-time modes, and confirmed reports were made by doctors in the remote expert-supporting system, while the traditional modes and detection systems were used in the Holter group. The results showed no significant differences between the two groups in 24-hour total heart rate (HR), averaged HR, maximum HR, minimum HR, premature atrial complexes (PACs) and premature ventricular complexes (PVCs) (P>0.05). The sensitivity and specificity of capture and remote automatic cardiac events detection of PACs, PVCs, and AF by H3-ECG were 93% and 99%, 98% and 99%, 94% and 98%, respectively. Therefore, the long-term limb triple-lead H3-ECG device can be utilized for domiciliary ECG self-monitoring and remote management of patients with common arrhythmia under medical supervision. Editorial Department of Journal of Biomedical Research 2021-05 2020-12-18 /pmc/articles/PMC8193711/ /pubmed/33495426 http://dx.doi.org/10.7555/JBR.34.20200074 Text en Copyright and License information: Journal of Biomedical Research, CAS Springer-Verlag Berlin Heidelberg 2021 https://creativecommons.org/licenses/by-nc-sa/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-Share Alike 4.0 Unported License. To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-sa/4.0/ (https://creativecommons.org/licenses/by-nc-sa/4.0/) |
spellingShingle | Original Article Shen, Qin Li, Jianqing Cui, Chang Wang, Xingyao Gao, Hongxiang Liu, Chengyu Chen, Minglong A wearable real-time telemonitoring electrocardiogram device compared with traditional Holter monitoring |
title | A wearable real-time telemonitoring electrocardiogram device compared with traditional Holter monitoring |
title_full | A wearable real-time telemonitoring electrocardiogram device compared with traditional Holter monitoring |
title_fullStr | A wearable real-time telemonitoring electrocardiogram device compared with traditional Holter monitoring |
title_full_unstemmed | A wearable real-time telemonitoring electrocardiogram device compared with traditional Holter monitoring |
title_short | A wearable real-time telemonitoring electrocardiogram device compared with traditional Holter monitoring |
title_sort | wearable real-time telemonitoring electrocardiogram device compared with traditional holter monitoring |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8193711/ https://www.ncbi.nlm.nih.gov/pubmed/33495426 http://dx.doi.org/10.7555/JBR.34.20200074 |
work_keys_str_mv | AT shenqin awearablerealtimetelemonitoringelectrocardiogramdevicecomparedwithtraditionalholtermonitoring AT lijianqing awearablerealtimetelemonitoringelectrocardiogramdevicecomparedwithtraditionalholtermonitoring AT cuichang awearablerealtimetelemonitoringelectrocardiogramdevicecomparedwithtraditionalholtermonitoring AT wangxingyao awearablerealtimetelemonitoringelectrocardiogramdevicecomparedwithtraditionalholtermonitoring AT gaohongxiang awearablerealtimetelemonitoringelectrocardiogramdevicecomparedwithtraditionalholtermonitoring AT liuchengyu awearablerealtimetelemonitoringelectrocardiogramdevicecomparedwithtraditionalholtermonitoring AT chenminglong awearablerealtimetelemonitoringelectrocardiogramdevicecomparedwithtraditionalholtermonitoring AT shenqin wearablerealtimetelemonitoringelectrocardiogramdevicecomparedwithtraditionalholtermonitoring AT lijianqing wearablerealtimetelemonitoringelectrocardiogramdevicecomparedwithtraditionalholtermonitoring AT cuichang wearablerealtimetelemonitoringelectrocardiogramdevicecomparedwithtraditionalholtermonitoring AT wangxingyao wearablerealtimetelemonitoringelectrocardiogramdevicecomparedwithtraditionalholtermonitoring AT gaohongxiang wearablerealtimetelemonitoringelectrocardiogramdevicecomparedwithtraditionalholtermonitoring AT liuchengyu wearablerealtimetelemonitoringelectrocardiogramdevicecomparedwithtraditionalholtermonitoring AT chenminglong wearablerealtimetelemonitoringelectrocardiogramdevicecomparedwithtraditionalholtermonitoring |