BACKGROUND: Non-union occurs in approximately 5 to 10% of fracture patients, with certain bones at greater risk of failing to heal. Non-unions have a significant impact on socioeconomic costs and the patients short and long-term quality of life. Low intensity pulsed ultrasound (LIPUS) is a non-invas...

Descripción completa

Detalles Bibliográficos
Autores principales: Leighton, Ross, Phillips, Mark, Bhandari, Mohit, Zura, Robert
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8196464/
https://www.ncbi.nlm.nih.gov/pubmed/34116673
http://dx.doi.org/10.1186/s12891-021-04322-5
_version_ 1783706694613729280
author Leighton, Ross
Phillips, Mark
Bhandari, Mohit
Zura, Robert
author_facet Leighton, Ross
Phillips, Mark
Bhandari, Mohit
Zura, Robert
author_sort Leighton, Ross
collection PubMed
description BACKGROUND: Non-union occurs in approximately 5 to 10% of fracture patients, with certain bones at greater risk of failing to heal. Non-unions have a significant impact on socioeconomic costs and the patients short and long-term quality of life. Low intensity pulsed ultrasound (LIPUS) is a non-invasive therapy for non-union treatment that can improve the long-term outcome. The purpose of this study is to summarize the available literature assessing LIPUS potential to improve the union rate in instrumented, infected, and fragility non-unions. METHODS: A literature search was conducted in the MEDLINE, EMBASE, and CINAHL databases for all relevant literature on the healing rates of LIPUS utilized in instrumented, infected, and fragility non-unions. Study characteristics were summarized for each of the included studies. The percentage of healed patients (healing rate), for instrumented, infected, and fragility fracture non-union patients were pooled from each included study. RESULTS: The literature search identified a total of 326 articles, while searching reference lists and grey literature identified an additional 3 articles. There was a total of 29 articles included in this review, with 20 articles included within the quantitative synthesis of healing rates. The most common design of included studies was case series (17 articles), followed by case reports (9 articles). Studies were primarily retrospective (18 studies), with an additional 10 prospective studies. Non-union healing rates were 82% (95% CI: 76 to 87%) in instrumented, 82% (95% CI: 70 to 95%) in infected, and 91% (95% CI: 87 to 95%) in fragility fracture patients with non-unions. CONCLUSION: This study has provided a thorough overview of the current literature on LIPUS treatment for instrumented, infected, and fragility fracture non-unions. The healing rates for non-unions in these subgroups were comparable to healing rates observed with LIPUS use in general non-union literature. LIPUS treatment should be considered as a conservative non-surgical treatment option to potentially reduce the socioeconomic impact and improve the quality of life of these unfortunate patients. LEVEL OF EVIDENCE: 4 (systematic review of primarily case series data) SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12891-021-04322-5.
format Online
Article
Text
id pubmed-8196464
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-81964642021-06-15 Low intensity pulsed ultrasound (LIPUS) use for the management of instrumented, infected, and fragility non-unions: a systematic review and meta-analysis of healing proportions Leighton, Ross Phillips, Mark Bhandari, Mohit Zura, Robert BMC Musculoskelet Disord Research Article BACKGROUND: Non-union occurs in approximately 5 to 10% of fracture patients, with certain bones at greater risk of failing to heal. Non-unions have a significant impact on socioeconomic costs and the patients short and long-term quality of life. Low intensity pulsed ultrasound (LIPUS) is a non-invasive therapy for non-union treatment that can improve the long-term outcome. The purpose of this study is to summarize the available literature assessing LIPUS potential to improve the union rate in instrumented, infected, and fragility non-unions. METHODS: A literature search was conducted in the MEDLINE, EMBASE, and CINAHL databases for all relevant literature on the healing rates of LIPUS utilized in instrumented, infected, and fragility non-unions. Study characteristics were summarized for each of the included studies. The percentage of healed patients (healing rate), for instrumented, infected, and fragility fracture non-union patients were pooled from each included study. RESULTS: The literature search identified a total of 326 articles, while searching reference lists and grey literature identified an additional 3 articles. There was a total of 29 articles included in this review, with 20 articles included within the quantitative synthesis of healing rates. The most common design of included studies was case series (17 articles), followed by case reports (9 articles). Studies were primarily retrospective (18 studies), with an additional 10 prospective studies. Non-union healing rates were 82% (95% CI: 76 to 87%) in instrumented, 82% (95% CI: 70 to 95%) in infected, and 91% (95% CI: 87 to 95%) in fragility fracture patients with non-unions. CONCLUSION: This study has provided a thorough overview of the current literature on LIPUS treatment for instrumented, infected, and fragility fracture non-unions. The healing rates for non-unions in these subgroups were comparable to healing rates observed with LIPUS use in general non-union literature. LIPUS treatment should be considered as a conservative non-surgical treatment option to potentially reduce the socioeconomic impact and improve the quality of life of these unfortunate patients. LEVEL OF EVIDENCE: 4 (systematic review of primarily case series data) SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12891-021-04322-5. BioMed Central 2021-06-11 /pmc/articles/PMC8196464/ /pubmed/34116673 http://dx.doi.org/10.1186/s12891-021-04322-5 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Leighton, Ross
Phillips, Mark
Bhandari, Mohit
Zura, Robert
Low intensity pulsed ultrasound (LIPUS) use for the management of instrumented, infected, and fragility non-unions: a systematic review and meta-analysis of healing proportions
title Low intensity pulsed ultrasound (LIPUS) use for the management of instrumented, infected, and fragility non-unions: a systematic review and meta-analysis of healing proportions
title_full Low intensity pulsed ultrasound (LIPUS) use for the management of instrumented, infected, and fragility non-unions: a systematic review and meta-analysis of healing proportions
title_fullStr Low intensity pulsed ultrasound (LIPUS) use for the management of instrumented, infected, and fragility non-unions: a systematic review and meta-analysis of healing proportions
title_full_unstemmed Low intensity pulsed ultrasound (LIPUS) use for the management of instrumented, infected, and fragility non-unions: a systematic review and meta-analysis of healing proportions
title_short Low intensity pulsed ultrasound (LIPUS) use for the management of instrumented, infected, and fragility non-unions: a systematic review and meta-analysis of healing proportions
title_sort low intensity pulsed ultrasound (lipus) use for the management of instrumented, infected, and fragility non-unions: a systematic review and meta-analysis of healing proportions
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8196464/
https://www.ncbi.nlm.nih.gov/pubmed/34116673
http://dx.doi.org/10.1186/s12891-021-04322-5
work_keys_str_mv AT leightonross lowintensitypulsedultrasoundlipususeforthemanagementofinstrumentedinfectedandfragilitynonunionsasystematicreviewandmetaanalysisofhealingproportions
AT phillipsmark lowintensitypulsedultrasoundlipususeforthemanagementofinstrumentedinfectedandfragilitynonunionsasystematicreviewandmetaanalysisofhealingproportions
AT bhandarimohit lowintensitypulsedultrasoundlipususeforthemanagementofinstrumentedinfectedandfragilitynonunionsasystematicreviewandmetaanalysisofhealingproportions
AT zurarobert lowintensitypulsedultrasoundlipususeforthemanagementofinstrumentedinfectedandfragilitynonunionsasystematicreviewandmetaanalysisofhealingproportions