Cargando…
Clinical diagnostic performance evaluation of five immunoassays for antibodies to SARS-CoV-2 diagnosis in a real-life routine care setting
While molecular techniques remain the gold standard for diagnosis of acute SARS-CoV-2 infection, serological tests have the unique potential to ascertain how much of the population has been exposed to the COVID-19 pathogen. There have been limited published studies to date documenting the performanc...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The African Field Epidemiology Network
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8197056/ https://www.ncbi.nlm.nih.gov/pubmed/34178231 http://dx.doi.org/10.11604/pamj.2021.39.3.26471 |
_version_ | 1783706831064924160 |
---|---|
author | Akyala, Adamu Ishaku Awayimbo, Jaggu Ruth Ogo, Anowai Clementina Chima, Ndubuisi John Billyrose, Olusoji Mathew Adeyemi Engom, Alaba Ovye Godiya |
author_facet | Akyala, Adamu Ishaku Awayimbo, Jaggu Ruth Ogo, Anowai Clementina Chima, Ndubuisi John Billyrose, Olusoji Mathew Adeyemi Engom, Alaba Ovye Godiya |
author_sort | Akyala, Adamu Ishaku |
collection | PubMed |
description | While molecular techniques remain the gold standard for diagnosis of acute SARS-CoV-2 infection, serological tests have the unique potential to ascertain how much of the population has been exposed to the COVID-19 pathogen. There have been limited published studies to date documenting the performance of SARS-CoV-2 antibody assays in Nigeria and so we evaluated the diagnostic performance of five (5) immunoassay on a set of clinical samples. Five automated immunoassays (2019-nCoV IgG/IgM antibody determination kit, Tigsun COVID-19 combo IgM/IgG rapid test, rapid response COVID-19 IgG/IgM test, COVID-19 IgM-IgG combined antibody rapid test, iChroma COVID-19 Ab) were tested. Three hundred and fourteen specimens were analyzed from health care workers who tested positive PCR for SARS-CoV-2 with symptoms consistent with SARS-CoV-2 receiving treatment at two treatment centres in Nasarawa State from March to September, 2020 with control of 134 health care workers who tested negative PCR for SARS-CoV-2 with no symptoms to SARS-CoV-2. The median patients' age was 40 years (IQR 39.8-41), majority were male and were on admission. The SARS-CoV-2 IgG/IgM antibody evaluated kits had a sensitivity of 33% (2019-nCoV IgG/IgM antibody determination kit), 22% (Tigsun COVID-19 combo IgM/IgG rapid test), 43% (rapid response COVID-19 IgG/IgM test), 44% (COVID-19 IgM-IgG combined antibody rapid test), 25% (iChroma COVID-19 Ab), 100% sensitivity, accuracy of 68.5% and Kappa coefficient of 0.7 and rapid response COVID-19 IgG/IgM test cassette had a sensitivity of 33%, specificity of 100% and accuracy of 72.5% with Kappa coefficient 0.7. The Tigsun COVID-19 combo IgM/IgG rapid test (lateral flow), positive, COVID-19 IgM-IgG combined antibody rapid test and iChroma COVID-19 Ab RT all had sensitivity of zero percent. Serology was complementary to RT-PCR for the diagnosis of COVID-19 at least 14 days after onset of symptoms. The assay panel needs to be improved to serve as an option for the diagnosis of SARS-CoV-2 in resource constrained settings where there are limited molecular diagnostics testing panels. |
format | Online Article Text |
id | pubmed-8197056 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | The African Field Epidemiology Network |
record_format | MEDLINE/PubMed |
spelling | pubmed-81970562021-06-24 Clinical diagnostic performance evaluation of five immunoassays for antibodies to SARS-CoV-2 diagnosis in a real-life routine care setting Akyala, Adamu Ishaku Awayimbo, Jaggu Ruth Ogo, Anowai Clementina Chima, Ndubuisi John Billyrose, Olusoji Mathew Adeyemi Engom, Alaba Ovye Godiya Pan Afr Med J Short Communication While molecular techniques remain the gold standard for diagnosis of acute SARS-CoV-2 infection, serological tests have the unique potential to ascertain how much of the population has been exposed to the COVID-19 pathogen. There have been limited published studies to date documenting the performance of SARS-CoV-2 antibody assays in Nigeria and so we evaluated the diagnostic performance of five (5) immunoassay on a set of clinical samples. Five automated immunoassays (2019-nCoV IgG/IgM antibody determination kit, Tigsun COVID-19 combo IgM/IgG rapid test, rapid response COVID-19 IgG/IgM test, COVID-19 IgM-IgG combined antibody rapid test, iChroma COVID-19 Ab) were tested. Three hundred and fourteen specimens were analyzed from health care workers who tested positive PCR for SARS-CoV-2 with symptoms consistent with SARS-CoV-2 receiving treatment at two treatment centres in Nasarawa State from March to September, 2020 with control of 134 health care workers who tested negative PCR for SARS-CoV-2 with no symptoms to SARS-CoV-2. The median patients' age was 40 years (IQR 39.8-41), majority were male and were on admission. The SARS-CoV-2 IgG/IgM antibody evaluated kits had a sensitivity of 33% (2019-nCoV IgG/IgM antibody determination kit), 22% (Tigsun COVID-19 combo IgM/IgG rapid test), 43% (rapid response COVID-19 IgG/IgM test), 44% (COVID-19 IgM-IgG combined antibody rapid test), 25% (iChroma COVID-19 Ab), 100% sensitivity, accuracy of 68.5% and Kappa coefficient of 0.7 and rapid response COVID-19 IgG/IgM test cassette had a sensitivity of 33%, specificity of 100% and accuracy of 72.5% with Kappa coefficient 0.7. The Tigsun COVID-19 combo IgM/IgG rapid test (lateral flow), positive, COVID-19 IgM-IgG combined antibody rapid test and iChroma COVID-19 Ab RT all had sensitivity of zero percent. Serology was complementary to RT-PCR for the diagnosis of COVID-19 at least 14 days after onset of symptoms. The assay panel needs to be improved to serve as an option for the diagnosis of SARS-CoV-2 in resource constrained settings where there are limited molecular diagnostics testing panels. The African Field Epidemiology Network 2021-05-03 /pmc/articles/PMC8197056/ /pubmed/34178231 http://dx.doi.org/10.11604/pamj.2021.39.3.26471 Text en Copyright: Adamu Ishaku Akyala et al. https://creativecommons.org/licenses/by/4.0/The Pan African Medical Journal (ISSN: 1937-8688). This is an Open Access article distributed under the terms of the Creative Commons Attribution International 4.0 License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Short Communication Akyala, Adamu Ishaku Awayimbo, Jaggu Ruth Ogo, Anowai Clementina Chima, Ndubuisi John Billyrose, Olusoji Mathew Adeyemi Engom, Alaba Ovye Godiya Clinical diagnostic performance evaluation of five immunoassays for antibodies to SARS-CoV-2 diagnosis in a real-life routine care setting |
title | Clinical diagnostic performance evaluation of five immunoassays for antibodies to SARS-CoV-2 diagnosis in a real-life routine care setting |
title_full | Clinical diagnostic performance evaluation of five immunoassays for antibodies to SARS-CoV-2 diagnosis in a real-life routine care setting |
title_fullStr | Clinical diagnostic performance evaluation of five immunoassays for antibodies to SARS-CoV-2 diagnosis in a real-life routine care setting |
title_full_unstemmed | Clinical diagnostic performance evaluation of five immunoassays for antibodies to SARS-CoV-2 diagnosis in a real-life routine care setting |
title_short | Clinical diagnostic performance evaluation of five immunoassays for antibodies to SARS-CoV-2 diagnosis in a real-life routine care setting |
title_sort | clinical diagnostic performance evaluation of five immunoassays for antibodies to sars-cov-2 diagnosis in a real-life routine care setting |
topic | Short Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8197056/ https://www.ncbi.nlm.nih.gov/pubmed/34178231 http://dx.doi.org/10.11604/pamj.2021.39.3.26471 |
work_keys_str_mv | AT akyalaadamuishaku clinicaldiagnosticperformanceevaluationoffiveimmunoassaysforantibodiestosarscov2diagnosisinarealliferoutinecaresetting AT awayimbojagguruth clinicaldiagnosticperformanceevaluationoffiveimmunoassaysforantibodiestosarscov2diagnosisinarealliferoutinecaresetting AT ogoanowaiclementina clinicaldiagnosticperformanceevaluationoffiveimmunoassaysforantibodiestosarscov2diagnosisinarealliferoutinecaresetting AT chimandubuisijohn clinicaldiagnosticperformanceevaluationoffiveimmunoassaysforantibodiestosarscov2diagnosisinarealliferoutinecaresetting AT billyroseolusojimathewadeyemi clinicaldiagnosticperformanceevaluationoffiveimmunoassaysforantibodiestosarscov2diagnosisinarealliferoutinecaresetting AT engomalabaovyegodiya clinicaldiagnosticperformanceevaluationoffiveimmunoassaysforantibodiestosarscov2diagnosisinarealliferoutinecaresetting |