Cargando…

Clinical diagnostic performance evaluation of five immunoassays for antibodies to SARS-CoV-2 diagnosis in a real-life routine care setting

While molecular techniques remain the gold standard for diagnosis of acute SARS-CoV-2 infection, serological tests have the unique potential to ascertain how much of the population has been exposed to the COVID-19 pathogen. There have been limited published studies to date documenting the performanc...

Descripción completa

Detalles Bibliográficos
Autores principales: Akyala, Adamu Ishaku, Awayimbo, Jaggu Ruth, Ogo, Anowai Clementina, Chima, Ndubuisi John, Billyrose, Olusoji Mathew Adeyemi, Engom, Alaba Ovye Godiya
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The African Field Epidemiology Network 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8197056/
https://www.ncbi.nlm.nih.gov/pubmed/34178231
http://dx.doi.org/10.11604/pamj.2021.39.3.26471
_version_ 1783706831064924160
author Akyala, Adamu Ishaku
Awayimbo, Jaggu Ruth
Ogo, Anowai Clementina
Chima, Ndubuisi John
Billyrose, Olusoji Mathew Adeyemi
Engom, Alaba Ovye Godiya
author_facet Akyala, Adamu Ishaku
Awayimbo, Jaggu Ruth
Ogo, Anowai Clementina
Chima, Ndubuisi John
Billyrose, Olusoji Mathew Adeyemi
Engom, Alaba Ovye Godiya
author_sort Akyala, Adamu Ishaku
collection PubMed
description While molecular techniques remain the gold standard for diagnosis of acute SARS-CoV-2 infection, serological tests have the unique potential to ascertain how much of the population has been exposed to the COVID-19 pathogen. There have been limited published studies to date documenting the performance of SARS-CoV-2 antibody assays in Nigeria and so we evaluated the diagnostic performance of five (5) immunoassay on a set of clinical samples. Five automated immunoassays (2019-nCoV IgG/IgM antibody determination kit, Tigsun COVID-19 combo IgM/IgG rapid test, rapid response COVID-19 IgG/IgM test, COVID-19 IgM-IgG combined antibody rapid test, iChroma COVID-19 Ab) were tested. Three hundred and fourteen specimens were analyzed from health care workers who tested positive PCR for SARS-CoV-2 with symptoms consistent with SARS-CoV-2 receiving treatment at two treatment centres in Nasarawa State from March to September, 2020 with control of 134 health care workers who tested negative PCR for SARS-CoV-2 with no symptoms to SARS-CoV-2. The median patients' age was 40 years (IQR 39.8-41), majority were male and were on admission. The SARS-CoV-2 IgG/IgM antibody evaluated kits had a sensitivity of 33% (2019-nCoV IgG/IgM antibody determination kit), 22% (Tigsun COVID-19 combo IgM/IgG rapid test), 43% (rapid response COVID-19 IgG/IgM test), 44% (COVID-19 IgM-IgG combined antibody rapid test), 25% (iChroma COVID-19 Ab), 100% sensitivity, accuracy of 68.5% and Kappa coefficient of 0.7 and rapid response COVID-19 IgG/IgM test cassette had a sensitivity of 33%, specificity of 100% and accuracy of 72.5% with Kappa coefficient 0.7. The Tigsun COVID-19 combo IgM/IgG rapid test (lateral flow), positive, COVID-19 IgM-IgG combined antibody rapid test and iChroma COVID-19 Ab RT all had sensitivity of zero percent. Serology was complementary to RT-PCR for the diagnosis of COVID-19 at least 14 days after onset of symptoms. The assay panel needs to be improved to serve as an option for the diagnosis of SARS-CoV-2 in resource constrained settings where there are limited molecular diagnostics testing panels.
format Online
Article
Text
id pubmed-8197056
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher The African Field Epidemiology Network
record_format MEDLINE/PubMed
spelling pubmed-81970562021-06-24 Clinical diagnostic performance evaluation of five immunoassays for antibodies to SARS-CoV-2 diagnosis in a real-life routine care setting Akyala, Adamu Ishaku Awayimbo, Jaggu Ruth Ogo, Anowai Clementina Chima, Ndubuisi John Billyrose, Olusoji Mathew Adeyemi Engom, Alaba Ovye Godiya Pan Afr Med J Short Communication While molecular techniques remain the gold standard for diagnosis of acute SARS-CoV-2 infection, serological tests have the unique potential to ascertain how much of the population has been exposed to the COVID-19 pathogen. There have been limited published studies to date documenting the performance of SARS-CoV-2 antibody assays in Nigeria and so we evaluated the diagnostic performance of five (5) immunoassay on a set of clinical samples. Five automated immunoassays (2019-nCoV IgG/IgM antibody determination kit, Tigsun COVID-19 combo IgM/IgG rapid test, rapid response COVID-19 IgG/IgM test, COVID-19 IgM-IgG combined antibody rapid test, iChroma COVID-19 Ab) were tested. Three hundred and fourteen specimens were analyzed from health care workers who tested positive PCR for SARS-CoV-2 with symptoms consistent with SARS-CoV-2 receiving treatment at two treatment centres in Nasarawa State from March to September, 2020 with control of 134 health care workers who tested negative PCR for SARS-CoV-2 with no symptoms to SARS-CoV-2. The median patients' age was 40 years (IQR 39.8-41), majority were male and were on admission. The SARS-CoV-2 IgG/IgM antibody evaluated kits had a sensitivity of 33% (2019-nCoV IgG/IgM antibody determination kit), 22% (Tigsun COVID-19 combo IgM/IgG rapid test), 43% (rapid response COVID-19 IgG/IgM test), 44% (COVID-19 IgM-IgG combined antibody rapid test), 25% (iChroma COVID-19 Ab), 100% sensitivity, accuracy of 68.5% and Kappa coefficient of 0.7 and rapid response COVID-19 IgG/IgM test cassette had a sensitivity of 33%, specificity of 100% and accuracy of 72.5% with Kappa coefficient 0.7. The Tigsun COVID-19 combo IgM/IgG rapid test (lateral flow), positive, COVID-19 IgM-IgG combined antibody rapid test and iChroma COVID-19 Ab RT all had sensitivity of zero percent. Serology was complementary to RT-PCR for the diagnosis of COVID-19 at least 14 days after onset of symptoms. The assay panel needs to be improved to serve as an option for the diagnosis of SARS-CoV-2 in resource constrained settings where there are limited molecular diagnostics testing panels. The African Field Epidemiology Network 2021-05-03 /pmc/articles/PMC8197056/ /pubmed/34178231 http://dx.doi.org/10.11604/pamj.2021.39.3.26471 Text en Copyright: Adamu Ishaku Akyala et al. https://creativecommons.org/licenses/by/4.0/The Pan African Medical Journal (ISSN: 1937-8688). This is an Open Access article distributed under the terms of the Creative Commons Attribution International 4.0 License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Short Communication
Akyala, Adamu Ishaku
Awayimbo, Jaggu Ruth
Ogo, Anowai Clementina
Chima, Ndubuisi John
Billyrose, Olusoji Mathew Adeyemi
Engom, Alaba Ovye Godiya
Clinical diagnostic performance evaluation of five immunoassays for antibodies to SARS-CoV-2 diagnosis in a real-life routine care setting
title Clinical diagnostic performance evaluation of five immunoassays for antibodies to SARS-CoV-2 diagnosis in a real-life routine care setting
title_full Clinical diagnostic performance evaluation of five immunoassays for antibodies to SARS-CoV-2 diagnosis in a real-life routine care setting
title_fullStr Clinical diagnostic performance evaluation of five immunoassays for antibodies to SARS-CoV-2 diagnosis in a real-life routine care setting
title_full_unstemmed Clinical diagnostic performance evaluation of five immunoassays for antibodies to SARS-CoV-2 diagnosis in a real-life routine care setting
title_short Clinical diagnostic performance evaluation of five immunoassays for antibodies to SARS-CoV-2 diagnosis in a real-life routine care setting
title_sort clinical diagnostic performance evaluation of five immunoassays for antibodies to sars-cov-2 diagnosis in a real-life routine care setting
topic Short Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8197056/
https://www.ncbi.nlm.nih.gov/pubmed/34178231
http://dx.doi.org/10.11604/pamj.2021.39.3.26471
work_keys_str_mv AT akyalaadamuishaku clinicaldiagnosticperformanceevaluationoffiveimmunoassaysforantibodiestosarscov2diagnosisinarealliferoutinecaresetting
AT awayimbojagguruth clinicaldiagnosticperformanceevaluationoffiveimmunoassaysforantibodiestosarscov2diagnosisinarealliferoutinecaresetting
AT ogoanowaiclementina clinicaldiagnosticperformanceevaluationoffiveimmunoassaysforantibodiestosarscov2diagnosisinarealliferoutinecaresetting
AT chimandubuisijohn clinicaldiagnosticperformanceevaluationoffiveimmunoassaysforantibodiestosarscov2diagnosisinarealliferoutinecaresetting
AT billyroseolusojimathewadeyemi clinicaldiagnosticperformanceevaluationoffiveimmunoassaysforantibodiestosarscov2diagnosisinarealliferoutinecaresetting
AT engomalabaovyegodiya clinicaldiagnosticperformanceevaluationoffiveimmunoassaysforantibodiestosarscov2diagnosisinarealliferoutinecaresetting