Cargando…
Validity of Lung Ultrasound: Is an Image Worth More Than a Thousand Sounds?
Introduction: There is debate as to whether lung-ultrasound (LUS) can replace lung-auscultation (LA) in the assessment of respiratory diseases. Methodology: The diagnostic validity, safety, and reliability of LA and LUS were analyzed in patients admitted in a pulmonary ward due to decompensated obst...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8197462/ https://www.ncbi.nlm.nih.gov/pubmed/34070387 http://dx.doi.org/10.3390/jcm10112292 |
Sumario: | Introduction: There is debate as to whether lung-ultrasound (LUS) can replace lung-auscultation (LA) in the assessment of respiratory diseases. Methodology: The diagnostic validity, safety, and reliability of LA and LUS were analyzed in patients admitted in a pulmonary ward due to decompensated obstructive airway diseases, decompensated interstitial diseases, and pulmonary infections, in a prospective study. Standard formulas were used to calculate the diagnostic sensitivity, specificity, and accuracy. The interobserver agreement with respect to the LA and LUS findings was evaluated based on the Kappa coefficient (ᴋ). Results: A total of 115 patients were studied. LUS was more sensitive than the LA in evaluating pulmonary infections (93.59% vs. 77.02%; p = 0.001) and more specifically in the case of decompensated obstructive airway diseases (95.6% vs. 19.10%; p = 0.001). The diagnostic accuracy of LUS was also greater in the case of pulmonary infections (75.65% vs. 60.90%; p = 0.02). The sensitivity and specificity of the combination of LA and LUS was 95.95%, 50% in pulmonary infections, 76.19%, 100% in case of decompensated obstructive airway diseases, and (100%, 88.54%) in case of interstitial diseases. (ᴋ) was 0.71 for an A-pattern, 0.73 for pathological B-lines, 0.94 for condensations, 0.89 for pleural-effusion, 0.63 for wheezes, 0.38 for rhonchi, 0.68 for fine crackles, 0.18 for coarse crackles, and 0.29 for a normal LA. Conclusions: There is a greater interobserver agreement in the interpretation of LUS-findings compared to that of LA-noises, their combined use improves diagnostic performance in all diseases examined. |
---|