Bio-corrosion impacts on mechanical integrity of ZM21 Mg for orthopaedic implant application processed by equal channel angular pressing

The mechanical integrity of rolled ZM21 Mg was improved by equal channel angular pressing (ECAP) to function as a potential biodegradable bone screw implant. Electron backscattered diffraction (EBSD) revealed deformed grains of 45 µm observed in rolled ZM21 Mg. They were transformed to equiaxed fine...

Descripción completa

Detalles Bibliográficos
Autores principales: Prithivirajan, S., Nyahale, Mayur Bapu, Naik, Gajanan M., Narendranath, S., Prabhu, Ashwini, Rekha, P. D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8197699/
https://www.ncbi.nlm.nih.gov/pubmed/34117928
http://dx.doi.org/10.1007/s10856-021-06535-5
_version_ 1783706973304258560
author Prithivirajan, S.
Nyahale, Mayur Bapu
Naik, Gajanan M.
Narendranath, S.
Prabhu, Ashwini
Rekha, P. D.
author_facet Prithivirajan, S.
Nyahale, Mayur Bapu
Naik, Gajanan M.
Narendranath, S.
Prabhu, Ashwini
Rekha, P. D.
author_sort Prithivirajan, S.
collection PubMed
description The mechanical integrity of rolled ZM21 Mg was improved by equal channel angular pressing (ECAP) to function as a potential biodegradable bone screw implant. Electron backscattered diffraction (EBSD) revealed deformed grains of 45 µm observed in rolled ZM21 Mg. They were transformed to equiaxed fine grains of 5.4 µm after 4(th) pass ECAP. The yield strength of rolled and ECAPed ZM21 Mg alloys were comparable. In contrast, 4(th) pass ZM21 Mg exhibited relatively higher elongation when compared to rolled sample. The mechanical properties of rolled and ECAPed ZM21 Mg were dependant on both grain refinement and crystallographic texture. The rolled and 4(th) pass ECAPed tensile samples exhibited nonlinear deterioration of mechanical properties when tested after 7, 14, 21 and 28 days immersion in Hank’s solution. The evaluation signifies that regardless their processing condition, ZM21 Mg alloys are suitable for surgical areas that requires high mechanical strength. In addition, the 4(th) pass ECAP samples were viable to MG-63 cells proving themselves to be promising candidates for future in vivo studies. [Image: see text]
format Online
Article
Text
id pubmed-8197699
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-81976992021-07-09 Bio-corrosion impacts on mechanical integrity of ZM21 Mg for orthopaedic implant application processed by equal channel angular pressing Prithivirajan, S. Nyahale, Mayur Bapu Naik, Gajanan M. Narendranath, S. Prabhu, Ashwini Rekha, P. D. J Mater Sci Mater Med Biomaterials Synthesis and Characterization The mechanical integrity of rolled ZM21 Mg was improved by equal channel angular pressing (ECAP) to function as a potential biodegradable bone screw implant. Electron backscattered diffraction (EBSD) revealed deformed grains of 45 µm observed in rolled ZM21 Mg. They were transformed to equiaxed fine grains of 5.4 µm after 4(th) pass ECAP. The yield strength of rolled and ECAPed ZM21 Mg alloys were comparable. In contrast, 4(th) pass ZM21 Mg exhibited relatively higher elongation when compared to rolled sample. The mechanical properties of rolled and ECAPed ZM21 Mg were dependant on both grain refinement and crystallographic texture. The rolled and 4(th) pass ECAPed tensile samples exhibited nonlinear deterioration of mechanical properties when tested after 7, 14, 21 and 28 days immersion in Hank’s solution. The evaluation signifies that regardless their processing condition, ZM21 Mg alloys are suitable for surgical areas that requires high mechanical strength. In addition, the 4(th) pass ECAP samples were viable to MG-63 cells proving themselves to be promising candidates for future in vivo studies. [Image: see text] Springer US 2021-06-12 2021 /pmc/articles/PMC8197699/ /pubmed/34117928 http://dx.doi.org/10.1007/s10856-021-06535-5 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Biomaterials Synthesis and Characterization
Prithivirajan, S.
Nyahale, Mayur Bapu
Naik, Gajanan M.
Narendranath, S.
Prabhu, Ashwini
Rekha, P. D.
Bio-corrosion impacts on mechanical integrity of ZM21 Mg for orthopaedic implant application processed by equal channel angular pressing
title Bio-corrosion impacts on mechanical integrity of ZM21 Mg for orthopaedic implant application processed by equal channel angular pressing
title_full Bio-corrosion impacts on mechanical integrity of ZM21 Mg for orthopaedic implant application processed by equal channel angular pressing
title_fullStr Bio-corrosion impacts on mechanical integrity of ZM21 Mg for orthopaedic implant application processed by equal channel angular pressing
title_full_unstemmed Bio-corrosion impacts on mechanical integrity of ZM21 Mg for orthopaedic implant application processed by equal channel angular pressing
title_short Bio-corrosion impacts on mechanical integrity of ZM21 Mg for orthopaedic implant application processed by equal channel angular pressing
title_sort bio-corrosion impacts on mechanical integrity of zm21 mg for orthopaedic implant application processed by equal channel angular pressing
topic Biomaterials Synthesis and Characterization
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8197699/
https://www.ncbi.nlm.nih.gov/pubmed/34117928
http://dx.doi.org/10.1007/s10856-021-06535-5
work_keys_str_mv AT prithivirajans biocorrosionimpactsonmechanicalintegrityofzm21mgfororthopaedicimplantapplicationprocessedbyequalchannelangularpressing
AT nyahalemayurbapu biocorrosionimpactsonmechanicalintegrityofzm21mgfororthopaedicimplantapplicationprocessedbyequalchannelangularpressing
AT naikgajananm biocorrosionimpactsonmechanicalintegrityofzm21mgfororthopaedicimplantapplicationprocessedbyequalchannelangularpressing
AT narendranaths biocorrosionimpactsonmechanicalintegrityofzm21mgfororthopaedicimplantapplicationprocessedbyequalchannelangularpressing
AT prabhuashwini biocorrosionimpactsonmechanicalintegrityofzm21mgfororthopaedicimplantapplicationprocessedbyequalchannelangularpressing
AT rekhapd biocorrosionimpactsonmechanicalintegrityofzm21mgfororthopaedicimplantapplicationprocessedbyequalchannelangularpressing