Cargando…

Usefulness of a Colonoscopy Cap with an External Grid for the Measurement of Small-Sized Colorectal Polyps: A Prospective Randomized Trial

Accurate measurement of polyp size during colonoscopy is crucial. The usefulness of cap-assisted colonoscopy and external grid application on monitor (gCAP) was evaluated for polyp size measurement in this 3-year, single-center, single-blind, randomized trial. Using the endoscopic forceps width as r...

Descripción completa

Detalles Bibliográficos
Autores principales: Han, Seul-Ki, Kim, Hyunil, Kim, Jin-woo, Kim, Hyun-Soo, Kim, Su-Young, Park, Hong-Jun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8197876/
https://www.ncbi.nlm.nih.gov/pubmed/34072225
http://dx.doi.org/10.3390/jcm10112365
_version_ 1783707006844010496
author Han, Seul-Ki
Kim, Hyunil
Kim, Jin-woo
Kim, Hyun-Soo
Kim, Su-Young
Park, Hong-Jun
author_facet Han, Seul-Ki
Kim, Hyunil
Kim, Jin-woo
Kim, Hyun-Soo
Kim, Su-Young
Park, Hong-Jun
author_sort Han, Seul-Ki
collection PubMed
description Accurate measurement of polyp size during colonoscopy is crucial. The usefulness of cap-assisted colonoscopy and external grid application on monitor (gCAP) was evaluated for polyp size measurement in this 3-year, single-center, single-blind, randomized trial. Using the endoscopic forceps width as reference, the discrepancy percent (DP), error rate (ER), and measurement time were compared between gCAP and visual estimation (VE) after randomization. ER was calculated within a 20% and 33% limit. From the 111 patients, 280 polyps were measured. The mean polyp sizes were 4.0 ± 1.7 mm and 4.2 ± 1.8 mm with gCAP and VE, respectively (p = 0.368). Compared with that by the forceps method, DP was significantly lower in the gCAP group than in the VE group. Moreover, ER was significantly lower in the gCAP group within its preset limit. The measurement time was 4 s longer in the gCAP group than in the VE group (8.2 ± 4.8 s vs. 4.2 ± 1.5 s; p < 0.001). However, the forceps method lasted 28 s longer than the others. On subgroup analysis by size, gCAP was more accurate for polyp size ≥ 5 mm. The gCAP method was more accurate for polyp size measurement than VE, especially for polyps ≥ 5 mm, and was more convenient than the forceps method.
format Online
Article
Text
id pubmed-8197876
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-81978762021-06-14 Usefulness of a Colonoscopy Cap with an External Grid for the Measurement of Small-Sized Colorectal Polyps: A Prospective Randomized Trial Han, Seul-Ki Kim, Hyunil Kim, Jin-woo Kim, Hyun-Soo Kim, Su-Young Park, Hong-Jun J Clin Med Article Accurate measurement of polyp size during colonoscopy is crucial. The usefulness of cap-assisted colonoscopy and external grid application on monitor (gCAP) was evaluated for polyp size measurement in this 3-year, single-center, single-blind, randomized trial. Using the endoscopic forceps width as reference, the discrepancy percent (DP), error rate (ER), and measurement time were compared between gCAP and visual estimation (VE) after randomization. ER was calculated within a 20% and 33% limit. From the 111 patients, 280 polyps were measured. The mean polyp sizes were 4.0 ± 1.7 mm and 4.2 ± 1.8 mm with gCAP and VE, respectively (p = 0.368). Compared with that by the forceps method, DP was significantly lower in the gCAP group than in the VE group. Moreover, ER was significantly lower in the gCAP group within its preset limit. The measurement time was 4 s longer in the gCAP group than in the VE group (8.2 ± 4.8 s vs. 4.2 ± 1.5 s; p < 0.001). However, the forceps method lasted 28 s longer than the others. On subgroup analysis by size, gCAP was more accurate for polyp size ≥ 5 mm. The gCAP method was more accurate for polyp size measurement than VE, especially for polyps ≥ 5 mm, and was more convenient than the forceps method. MDPI 2021-05-27 /pmc/articles/PMC8197876/ /pubmed/34072225 http://dx.doi.org/10.3390/jcm10112365 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Han, Seul-Ki
Kim, Hyunil
Kim, Jin-woo
Kim, Hyun-Soo
Kim, Su-Young
Park, Hong-Jun
Usefulness of a Colonoscopy Cap with an External Grid for the Measurement of Small-Sized Colorectal Polyps: A Prospective Randomized Trial
title Usefulness of a Colonoscopy Cap with an External Grid for the Measurement of Small-Sized Colorectal Polyps: A Prospective Randomized Trial
title_full Usefulness of a Colonoscopy Cap with an External Grid for the Measurement of Small-Sized Colorectal Polyps: A Prospective Randomized Trial
title_fullStr Usefulness of a Colonoscopy Cap with an External Grid for the Measurement of Small-Sized Colorectal Polyps: A Prospective Randomized Trial
title_full_unstemmed Usefulness of a Colonoscopy Cap with an External Grid for the Measurement of Small-Sized Colorectal Polyps: A Prospective Randomized Trial
title_short Usefulness of a Colonoscopy Cap with an External Grid for the Measurement of Small-Sized Colorectal Polyps: A Prospective Randomized Trial
title_sort usefulness of a colonoscopy cap with an external grid for the measurement of small-sized colorectal polyps: a prospective randomized trial
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8197876/
https://www.ncbi.nlm.nih.gov/pubmed/34072225
http://dx.doi.org/10.3390/jcm10112365
work_keys_str_mv AT hanseulki usefulnessofacolonoscopycapwithanexternalgridforthemeasurementofsmallsizedcolorectalpolypsaprospectiverandomizedtrial
AT kimhyunil usefulnessofacolonoscopycapwithanexternalgridforthemeasurementofsmallsizedcolorectalpolypsaprospectiverandomizedtrial
AT kimjinwoo usefulnessofacolonoscopycapwithanexternalgridforthemeasurementofsmallsizedcolorectalpolypsaprospectiverandomizedtrial
AT kimhyunsoo usefulnessofacolonoscopycapwithanexternalgridforthemeasurementofsmallsizedcolorectalpolypsaprospectiverandomizedtrial
AT kimsuyoung usefulnessofacolonoscopycapwithanexternalgridforthemeasurementofsmallsizedcolorectalpolypsaprospectiverandomizedtrial
AT parkhongjun usefulnessofacolonoscopycapwithanexternalgridforthemeasurementofsmallsizedcolorectalpolypsaprospectiverandomizedtrial