Cargando…
Usefulness of a Colonoscopy Cap with an External Grid for the Measurement of Small-Sized Colorectal Polyps: A Prospective Randomized Trial
Accurate measurement of polyp size during colonoscopy is crucial. The usefulness of cap-assisted colonoscopy and external grid application on monitor (gCAP) was evaluated for polyp size measurement in this 3-year, single-center, single-blind, randomized trial. Using the endoscopic forceps width as r...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8197876/ https://www.ncbi.nlm.nih.gov/pubmed/34072225 http://dx.doi.org/10.3390/jcm10112365 |
_version_ | 1783707006844010496 |
---|---|
author | Han, Seul-Ki Kim, Hyunil Kim, Jin-woo Kim, Hyun-Soo Kim, Su-Young Park, Hong-Jun |
author_facet | Han, Seul-Ki Kim, Hyunil Kim, Jin-woo Kim, Hyun-Soo Kim, Su-Young Park, Hong-Jun |
author_sort | Han, Seul-Ki |
collection | PubMed |
description | Accurate measurement of polyp size during colonoscopy is crucial. The usefulness of cap-assisted colonoscopy and external grid application on monitor (gCAP) was evaluated for polyp size measurement in this 3-year, single-center, single-blind, randomized trial. Using the endoscopic forceps width as reference, the discrepancy percent (DP), error rate (ER), and measurement time were compared between gCAP and visual estimation (VE) after randomization. ER was calculated within a 20% and 33% limit. From the 111 patients, 280 polyps were measured. The mean polyp sizes were 4.0 ± 1.7 mm and 4.2 ± 1.8 mm with gCAP and VE, respectively (p = 0.368). Compared with that by the forceps method, DP was significantly lower in the gCAP group than in the VE group. Moreover, ER was significantly lower in the gCAP group within its preset limit. The measurement time was 4 s longer in the gCAP group than in the VE group (8.2 ± 4.8 s vs. 4.2 ± 1.5 s; p < 0.001). However, the forceps method lasted 28 s longer than the others. On subgroup analysis by size, gCAP was more accurate for polyp size ≥ 5 mm. The gCAP method was more accurate for polyp size measurement than VE, especially for polyps ≥ 5 mm, and was more convenient than the forceps method. |
format | Online Article Text |
id | pubmed-8197876 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-81978762021-06-14 Usefulness of a Colonoscopy Cap with an External Grid for the Measurement of Small-Sized Colorectal Polyps: A Prospective Randomized Trial Han, Seul-Ki Kim, Hyunil Kim, Jin-woo Kim, Hyun-Soo Kim, Su-Young Park, Hong-Jun J Clin Med Article Accurate measurement of polyp size during colonoscopy is crucial. The usefulness of cap-assisted colonoscopy and external grid application on monitor (gCAP) was evaluated for polyp size measurement in this 3-year, single-center, single-blind, randomized trial. Using the endoscopic forceps width as reference, the discrepancy percent (DP), error rate (ER), and measurement time were compared between gCAP and visual estimation (VE) after randomization. ER was calculated within a 20% and 33% limit. From the 111 patients, 280 polyps were measured. The mean polyp sizes were 4.0 ± 1.7 mm and 4.2 ± 1.8 mm with gCAP and VE, respectively (p = 0.368). Compared with that by the forceps method, DP was significantly lower in the gCAP group than in the VE group. Moreover, ER was significantly lower in the gCAP group within its preset limit. The measurement time was 4 s longer in the gCAP group than in the VE group (8.2 ± 4.8 s vs. 4.2 ± 1.5 s; p < 0.001). However, the forceps method lasted 28 s longer than the others. On subgroup analysis by size, gCAP was more accurate for polyp size ≥ 5 mm. The gCAP method was more accurate for polyp size measurement than VE, especially for polyps ≥ 5 mm, and was more convenient than the forceps method. MDPI 2021-05-27 /pmc/articles/PMC8197876/ /pubmed/34072225 http://dx.doi.org/10.3390/jcm10112365 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Han, Seul-Ki Kim, Hyunil Kim, Jin-woo Kim, Hyun-Soo Kim, Su-Young Park, Hong-Jun Usefulness of a Colonoscopy Cap with an External Grid for the Measurement of Small-Sized Colorectal Polyps: A Prospective Randomized Trial |
title | Usefulness of a Colonoscopy Cap with an External Grid for the Measurement of Small-Sized Colorectal Polyps: A Prospective Randomized Trial |
title_full | Usefulness of a Colonoscopy Cap with an External Grid for the Measurement of Small-Sized Colorectal Polyps: A Prospective Randomized Trial |
title_fullStr | Usefulness of a Colonoscopy Cap with an External Grid for the Measurement of Small-Sized Colorectal Polyps: A Prospective Randomized Trial |
title_full_unstemmed | Usefulness of a Colonoscopy Cap with an External Grid for the Measurement of Small-Sized Colorectal Polyps: A Prospective Randomized Trial |
title_short | Usefulness of a Colonoscopy Cap with an External Grid for the Measurement of Small-Sized Colorectal Polyps: A Prospective Randomized Trial |
title_sort | usefulness of a colonoscopy cap with an external grid for the measurement of small-sized colorectal polyps: a prospective randomized trial |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8197876/ https://www.ncbi.nlm.nih.gov/pubmed/34072225 http://dx.doi.org/10.3390/jcm10112365 |
work_keys_str_mv | AT hanseulki usefulnessofacolonoscopycapwithanexternalgridforthemeasurementofsmallsizedcolorectalpolypsaprospectiverandomizedtrial AT kimhyunil usefulnessofacolonoscopycapwithanexternalgridforthemeasurementofsmallsizedcolorectalpolypsaprospectiverandomizedtrial AT kimjinwoo usefulnessofacolonoscopycapwithanexternalgridforthemeasurementofsmallsizedcolorectalpolypsaprospectiverandomizedtrial AT kimhyunsoo usefulnessofacolonoscopycapwithanexternalgridforthemeasurementofsmallsizedcolorectalpolypsaprospectiverandomizedtrial AT kimsuyoung usefulnessofacolonoscopycapwithanexternalgridforthemeasurementofsmallsizedcolorectalpolypsaprospectiverandomizedtrial AT parkhongjun usefulnessofacolonoscopycapwithanexternalgridforthemeasurementofsmallsizedcolorectalpolypsaprospectiverandomizedtrial |