Cargando…
Effect of Different Head Hole Position on the Rotational Resistance and Stability of Orthodontic Miniscrews: A Three-Dimensional Finite Element Study
The orthodontic miniscrew is driven into bone in a clockwise direction. Counter-clockwise rotational force applied to the implanted miniscrew can degrade the stability. The purpose of this three-dimensional finite element study was to figure out the effect of shifting the miniscrew head hole positio...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8198358/ https://www.ncbi.nlm.nih.gov/pubmed/34070904 http://dx.doi.org/10.3390/s21113798 |
_version_ | 1783707119321612288 |
---|---|
author | Choi, Jin-Young Kim, Min-Jung Kim, Seong-Hun Chung, Kyu-Rhim Nelson, Gerald |
author_facet | Choi, Jin-Young Kim, Min-Jung Kim, Seong-Hun Chung, Kyu-Rhim Nelson, Gerald |
author_sort | Choi, Jin-Young |
collection | PubMed |
description | The orthodontic miniscrew is driven into bone in a clockwise direction. Counter-clockwise rotational force applied to the implanted miniscrew can degrade the stability. The purpose of this three-dimensional finite element study was to figure out the effect of shifting the miniscrew head hole position from the long axis. Two miniscrew models were developed, one with the head hole at the long axis and the other with an eccentric hole position. One degree of counter-clockwise rotation was applied to both groups, and the maximum Von-Mises stress and moment was measured under various wire insertion angles from −60° to +60°. All Von-Mises stress and moments increased with an increase in rotational angle or wire insertion angle. The increasing slope of moment in the eccentric hole group was significantly higher than that in the centric hole group. Although the maximum Von-Mises stress was higher in the eccentric hole group, the distribution of stress was not very different from the centric hole group. As the positive wire insertion angles generated a higher moment under a counter-clockwise rotational force, it is recommended to place the head hole considering the implanting direction of the miniscrew. Clinically, multidirectional and higher forces can be applied to the miniscrew with an eccentric head hole position. |
format | Online Article Text |
id | pubmed-8198358 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-81983582021-06-14 Effect of Different Head Hole Position on the Rotational Resistance and Stability of Orthodontic Miniscrews: A Three-Dimensional Finite Element Study Choi, Jin-Young Kim, Min-Jung Kim, Seong-Hun Chung, Kyu-Rhim Nelson, Gerald Sensors (Basel) Article The orthodontic miniscrew is driven into bone in a clockwise direction. Counter-clockwise rotational force applied to the implanted miniscrew can degrade the stability. The purpose of this three-dimensional finite element study was to figure out the effect of shifting the miniscrew head hole position from the long axis. Two miniscrew models were developed, one with the head hole at the long axis and the other with an eccentric hole position. One degree of counter-clockwise rotation was applied to both groups, and the maximum Von-Mises stress and moment was measured under various wire insertion angles from −60° to +60°. All Von-Mises stress and moments increased with an increase in rotational angle or wire insertion angle. The increasing slope of moment in the eccentric hole group was significantly higher than that in the centric hole group. Although the maximum Von-Mises stress was higher in the eccentric hole group, the distribution of stress was not very different from the centric hole group. As the positive wire insertion angles generated a higher moment under a counter-clockwise rotational force, it is recommended to place the head hole considering the implanting direction of the miniscrew. Clinically, multidirectional and higher forces can be applied to the miniscrew with an eccentric head hole position. MDPI 2021-05-30 /pmc/articles/PMC8198358/ /pubmed/34070904 http://dx.doi.org/10.3390/s21113798 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Choi, Jin-Young Kim, Min-Jung Kim, Seong-Hun Chung, Kyu-Rhim Nelson, Gerald Effect of Different Head Hole Position on the Rotational Resistance and Stability of Orthodontic Miniscrews: A Three-Dimensional Finite Element Study |
title | Effect of Different Head Hole Position on the Rotational Resistance and Stability of Orthodontic Miniscrews: A Three-Dimensional Finite Element Study |
title_full | Effect of Different Head Hole Position on the Rotational Resistance and Stability of Orthodontic Miniscrews: A Three-Dimensional Finite Element Study |
title_fullStr | Effect of Different Head Hole Position on the Rotational Resistance and Stability of Orthodontic Miniscrews: A Three-Dimensional Finite Element Study |
title_full_unstemmed | Effect of Different Head Hole Position on the Rotational Resistance and Stability of Orthodontic Miniscrews: A Three-Dimensional Finite Element Study |
title_short | Effect of Different Head Hole Position on the Rotational Resistance and Stability of Orthodontic Miniscrews: A Three-Dimensional Finite Element Study |
title_sort | effect of different head hole position on the rotational resistance and stability of orthodontic miniscrews: a three-dimensional finite element study |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8198358/ https://www.ncbi.nlm.nih.gov/pubmed/34070904 http://dx.doi.org/10.3390/s21113798 |
work_keys_str_mv | AT choijinyoung effectofdifferentheadholepositionontherotationalresistanceandstabilityoforthodonticminiscrewsathreedimensionalfiniteelementstudy AT kimminjung effectofdifferentheadholepositionontherotationalresistanceandstabilityoforthodonticminiscrewsathreedimensionalfiniteelementstudy AT kimseonghun effectofdifferentheadholepositionontherotationalresistanceandstabilityoforthodonticminiscrewsathreedimensionalfiniteelementstudy AT chungkyurhim effectofdifferentheadholepositionontherotationalresistanceandstabilityoforthodonticminiscrewsathreedimensionalfiniteelementstudy AT nelsongerald effectofdifferentheadholepositionontherotationalresistanceandstabilityoforthodonticminiscrewsathreedimensionalfiniteelementstudy |