Cargando…

Effect of Different Head Hole Position on the Rotational Resistance and Stability of Orthodontic Miniscrews: A Three-Dimensional Finite Element Study

The orthodontic miniscrew is driven into bone in a clockwise direction. Counter-clockwise rotational force applied to the implanted miniscrew can degrade the stability. The purpose of this three-dimensional finite element study was to figure out the effect of shifting the miniscrew head hole positio...

Descripción completa

Detalles Bibliográficos
Autores principales: Choi, Jin-Young, Kim, Min-Jung, Kim, Seong-Hun, Chung, Kyu-Rhim, Nelson, Gerald
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8198358/
https://www.ncbi.nlm.nih.gov/pubmed/34070904
http://dx.doi.org/10.3390/s21113798
_version_ 1783707119321612288
author Choi, Jin-Young
Kim, Min-Jung
Kim, Seong-Hun
Chung, Kyu-Rhim
Nelson, Gerald
author_facet Choi, Jin-Young
Kim, Min-Jung
Kim, Seong-Hun
Chung, Kyu-Rhim
Nelson, Gerald
author_sort Choi, Jin-Young
collection PubMed
description The orthodontic miniscrew is driven into bone in a clockwise direction. Counter-clockwise rotational force applied to the implanted miniscrew can degrade the stability. The purpose of this three-dimensional finite element study was to figure out the effect of shifting the miniscrew head hole position from the long axis. Two miniscrew models were developed, one with the head hole at the long axis and the other with an eccentric hole position. One degree of counter-clockwise rotation was applied to both groups, and the maximum Von-Mises stress and moment was measured under various wire insertion angles from −60° to +60°. All Von-Mises stress and moments increased with an increase in rotational angle or wire insertion angle. The increasing slope of moment in the eccentric hole group was significantly higher than that in the centric hole group. Although the maximum Von-Mises stress was higher in the eccentric hole group, the distribution of stress was not very different from the centric hole group. As the positive wire insertion angles generated a higher moment under a counter-clockwise rotational force, it is recommended to place the head hole considering the implanting direction of the miniscrew. Clinically, multidirectional and higher forces can be applied to the miniscrew with an eccentric head hole position.
format Online
Article
Text
id pubmed-8198358
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-81983582021-06-14 Effect of Different Head Hole Position on the Rotational Resistance and Stability of Orthodontic Miniscrews: A Three-Dimensional Finite Element Study Choi, Jin-Young Kim, Min-Jung Kim, Seong-Hun Chung, Kyu-Rhim Nelson, Gerald Sensors (Basel) Article The orthodontic miniscrew is driven into bone in a clockwise direction. Counter-clockwise rotational force applied to the implanted miniscrew can degrade the stability. The purpose of this three-dimensional finite element study was to figure out the effect of shifting the miniscrew head hole position from the long axis. Two miniscrew models were developed, one with the head hole at the long axis and the other with an eccentric hole position. One degree of counter-clockwise rotation was applied to both groups, and the maximum Von-Mises stress and moment was measured under various wire insertion angles from −60° to +60°. All Von-Mises stress and moments increased with an increase in rotational angle or wire insertion angle. The increasing slope of moment in the eccentric hole group was significantly higher than that in the centric hole group. Although the maximum Von-Mises stress was higher in the eccentric hole group, the distribution of stress was not very different from the centric hole group. As the positive wire insertion angles generated a higher moment under a counter-clockwise rotational force, it is recommended to place the head hole considering the implanting direction of the miniscrew. Clinically, multidirectional and higher forces can be applied to the miniscrew with an eccentric head hole position. MDPI 2021-05-30 /pmc/articles/PMC8198358/ /pubmed/34070904 http://dx.doi.org/10.3390/s21113798 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Choi, Jin-Young
Kim, Min-Jung
Kim, Seong-Hun
Chung, Kyu-Rhim
Nelson, Gerald
Effect of Different Head Hole Position on the Rotational Resistance and Stability of Orthodontic Miniscrews: A Three-Dimensional Finite Element Study
title Effect of Different Head Hole Position on the Rotational Resistance and Stability of Orthodontic Miniscrews: A Three-Dimensional Finite Element Study
title_full Effect of Different Head Hole Position on the Rotational Resistance and Stability of Orthodontic Miniscrews: A Three-Dimensional Finite Element Study
title_fullStr Effect of Different Head Hole Position on the Rotational Resistance and Stability of Orthodontic Miniscrews: A Three-Dimensional Finite Element Study
title_full_unstemmed Effect of Different Head Hole Position on the Rotational Resistance and Stability of Orthodontic Miniscrews: A Three-Dimensional Finite Element Study
title_short Effect of Different Head Hole Position on the Rotational Resistance and Stability of Orthodontic Miniscrews: A Three-Dimensional Finite Element Study
title_sort effect of different head hole position on the rotational resistance and stability of orthodontic miniscrews: a three-dimensional finite element study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8198358/
https://www.ncbi.nlm.nih.gov/pubmed/34070904
http://dx.doi.org/10.3390/s21113798
work_keys_str_mv AT choijinyoung effectofdifferentheadholepositionontherotationalresistanceandstabilityoforthodonticminiscrewsathreedimensionalfiniteelementstudy
AT kimminjung effectofdifferentheadholepositionontherotationalresistanceandstabilityoforthodonticminiscrewsathreedimensionalfiniteelementstudy
AT kimseonghun effectofdifferentheadholepositionontherotationalresistanceandstabilityoforthodonticminiscrewsathreedimensionalfiniteelementstudy
AT chungkyurhim effectofdifferentheadholepositionontherotationalresistanceandstabilityoforthodonticminiscrewsathreedimensionalfiniteelementstudy
AT nelsongerald effectofdifferentheadholepositionontherotationalresistanceandstabilityoforthodonticminiscrewsathreedimensionalfiniteelementstudy