Cargando…
Evaluation of the Feasibility and Effectiveness of Placement of Fully Covered Self-Expandable Metallic Stents via Various Insertion Routes for Benign Biliary Strictures
Background and aims: The goals of the management of benign biliary stricture (BBS) are to relieve symptoms and resolve short-/long-term stricture. We performed fully covered self-expandable metallic stent (hereafter, FCSEMS) placement for BBS using various methods and investigated the treatment outc...
Autores principales: | , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8198386/ https://www.ncbi.nlm.nih.gov/pubmed/34071678 http://dx.doi.org/10.3390/jcm10112397 |
Sumario: | Background and aims: The goals of the management of benign biliary stricture (BBS) are to relieve symptoms and resolve short-/long-term stricture. We performed fully covered self-expandable metallic stent (hereafter, FCSEMS) placement for BBS using various methods and investigated the treatment outcomes and adverse events (AEs). Methods: We retrospectively studied patients who underwent FCSEMS placement for refractory BBS through various approaches between January 2017 and February 2020. FCSEMS were placed for 6 months, and an additional FCSEMS was placed if the stricture had not improved. Technical success rate, stricture resolution rate, and AE were measured. Results: A total of 26 patients with BBSs that were difficult to manage with plastic stents were included. The mean overall follow-up period was 43.3 ± 30.7 months. The cause of stricture was postoperative (46%), inflammatory (31%), and chronic pancreatitis (23%). There were four insertion methods: endoscopic with duodenoscopy, with enteroscopy, EUS-guided transmural, and percutaneous transhepatic. The technical success rate was 100%, without any AE. Stricture resolution was obtained in 19 (83%) of 23 cases, except for three cases of death due to other causes. Stent migration and cholangitis occurred in 23% and 6.3%, respectively. Stent fracture occurred in two cases in which FCSEMSs were placed for more than 6 months (7.2 and 10.3 months). Conclusion: FCSEMS placement for refractory BBS via various insertion routes was feasible and effective. FCSEMSs should be exchanged every 6 months until stricture resolution because of stent durability. Further prospective study for confirmation is required, particularly regarding EUS-guided FCSEMS placement. |
---|