The eSpiro Ventilator: An Open-Source Response to a Worldwide Pandemic
Objective: To address the issue of ventilator shortages, our group (eSpiro Network) developed a freely replicable, open-source hardware ventilator. Design: We performed a bench study. Setting: Dedicated research room as part of an ICU affiliated to a university hospital. Subjects: We set the lung mo...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8198783/ https://www.ncbi.nlm.nih.gov/pubmed/34071778 http://dx.doi.org/10.3390/jcm10112336 |
_version_ | 1783707220999929856 |
---|---|
author | Terzi, Nicolas Rastello, Fabrice Déhan, Christophe Roux, Marion Sigaud, Florian Rigault, Guillaume Fromentin, Cyril Farrugia, Adrien Guérin, Claude |
author_facet | Terzi, Nicolas Rastello, Fabrice Déhan, Christophe Roux, Marion Sigaud, Florian Rigault, Guillaume Fromentin, Cyril Farrugia, Adrien Guérin, Claude |
author_sort | Terzi, Nicolas |
collection | PubMed |
description | Objective: To address the issue of ventilator shortages, our group (eSpiro Network) developed a freely replicable, open-source hardware ventilator. Design: We performed a bench study. Setting: Dedicated research room as part of an ICU affiliated to a university hospital. Subjects: We set the lung model with three conditions of resistance and linear compliance for mimicking different respiratory mechanics of representative intensive care unit (ICU) patients. Interventions: The performance of the device was tested using the ASL5000 lung model. Measurements and Main Results: Twenty-seven conditions were tested. All the measurements fell within the ±10% limits for the tidal volume (V(T)). The volume error was influenced by the mechanical condition (p = 5.9 × 10(−15)) and the PEEP level (P = 1.1 × 10(−12)) but the clinical significance of this finding is likely meaningless (maximum −34 mL in the error). The PEEP error was not influenced by the mechanical condition (p = 0.25). Our experimental results demonstrate that the eSpiro ventilator is reliable to deliver V(T) and PEEP accurately in various respiratory mechanics conditions. Conclusions: We report a low-cost, easy-to-build ventilator, which is reliable to deliver V(T) and PEEP in passive invasive mechanical ventilation. |
format | Online Article Text |
id | pubmed-8198783 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-81987832021-06-14 The eSpiro Ventilator: An Open-Source Response to a Worldwide Pandemic Terzi, Nicolas Rastello, Fabrice Déhan, Christophe Roux, Marion Sigaud, Florian Rigault, Guillaume Fromentin, Cyril Farrugia, Adrien Guérin, Claude J Clin Med Article Objective: To address the issue of ventilator shortages, our group (eSpiro Network) developed a freely replicable, open-source hardware ventilator. Design: We performed a bench study. Setting: Dedicated research room as part of an ICU affiliated to a university hospital. Subjects: We set the lung model with three conditions of resistance and linear compliance for mimicking different respiratory mechanics of representative intensive care unit (ICU) patients. Interventions: The performance of the device was tested using the ASL5000 lung model. Measurements and Main Results: Twenty-seven conditions were tested. All the measurements fell within the ±10% limits for the tidal volume (V(T)). The volume error was influenced by the mechanical condition (p = 5.9 × 10(−15)) and the PEEP level (P = 1.1 × 10(−12)) but the clinical significance of this finding is likely meaningless (maximum −34 mL in the error). The PEEP error was not influenced by the mechanical condition (p = 0.25). Our experimental results demonstrate that the eSpiro ventilator is reliable to deliver V(T) and PEEP accurately in various respiratory mechanics conditions. Conclusions: We report a low-cost, easy-to-build ventilator, which is reliable to deliver V(T) and PEEP in passive invasive mechanical ventilation. MDPI 2021-05-27 /pmc/articles/PMC8198783/ /pubmed/34071778 http://dx.doi.org/10.3390/jcm10112336 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Terzi, Nicolas Rastello, Fabrice Déhan, Christophe Roux, Marion Sigaud, Florian Rigault, Guillaume Fromentin, Cyril Farrugia, Adrien Guérin, Claude The eSpiro Ventilator: An Open-Source Response to a Worldwide Pandemic |
title | The eSpiro Ventilator: An Open-Source Response to a Worldwide Pandemic |
title_full | The eSpiro Ventilator: An Open-Source Response to a Worldwide Pandemic |
title_fullStr | The eSpiro Ventilator: An Open-Source Response to a Worldwide Pandemic |
title_full_unstemmed | The eSpiro Ventilator: An Open-Source Response to a Worldwide Pandemic |
title_short | The eSpiro Ventilator: An Open-Source Response to a Worldwide Pandemic |
title_sort | espiro ventilator: an open-source response to a worldwide pandemic |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8198783/ https://www.ncbi.nlm.nih.gov/pubmed/34071778 http://dx.doi.org/10.3390/jcm10112336 |
work_keys_str_mv | AT terzinicolas theespiroventilatoranopensourceresponsetoaworldwidepandemic AT rastellofabrice theespiroventilatoranopensourceresponsetoaworldwidepandemic AT dehanchristophe theespiroventilatoranopensourceresponsetoaworldwidepandemic AT rouxmarion theespiroventilatoranopensourceresponsetoaworldwidepandemic AT sigaudflorian theespiroventilatoranopensourceresponsetoaworldwidepandemic AT rigaultguillaume theespiroventilatoranopensourceresponsetoaworldwidepandemic AT fromentincyril theespiroventilatoranopensourceresponsetoaworldwidepandemic AT farrugiaadrien theespiroventilatoranopensourceresponsetoaworldwidepandemic AT guerinclaude theespiroventilatoranopensourceresponsetoaworldwidepandemic AT terzinicolas espiroventilatoranopensourceresponsetoaworldwidepandemic AT rastellofabrice espiroventilatoranopensourceresponsetoaworldwidepandemic AT dehanchristophe espiroventilatoranopensourceresponsetoaworldwidepandemic AT rouxmarion espiroventilatoranopensourceresponsetoaworldwidepandemic AT sigaudflorian espiroventilatoranopensourceresponsetoaworldwidepandemic AT rigaultguillaume espiroventilatoranopensourceresponsetoaworldwidepandemic AT fromentincyril espiroventilatoranopensourceresponsetoaworldwidepandemic AT farrugiaadrien espiroventilatoranopensourceresponsetoaworldwidepandemic AT guerinclaude espiroventilatoranopensourceresponsetoaworldwidepandemic |