Cargando…

Reference Intervals of Thyroid Function Tests Assessed by Immunoassay and Mass Spectrometry in Healthy Pregnant Women Living in Catalonia

Background: Recent guidelines recommend establishing a local reference interval (RI) for thyroid function. We aimed to establish trimester-specific RIs for thyrotropin (TSH) and free thyroxine (FT4) in a cohort of healthy pregnant women in Catalonia (Spain). Methods: A prospective observational stud...

Descripción completa

Detalles Bibliográficos
Autores principales: Hernández, José María, Soldevila, Berta, Velasco, Inés, Moreno-Flores, Fernando, Ferrer, Laura, Pérez-Montes de Oca, Alejandra, Santillán, Cecilia, Muñoz, Carla, Ballesta, Sílvia, Canal, Cristina, Puig-Domingo, Manel, Granada, María Luisa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8198941/
https://www.ncbi.nlm.nih.gov/pubmed/34072898
http://dx.doi.org/10.3390/jcm10112444
_version_ 1783707258818920448
author Hernández, José María
Soldevila, Berta
Velasco, Inés
Moreno-Flores, Fernando
Ferrer, Laura
Pérez-Montes de Oca, Alejandra
Santillán, Cecilia
Muñoz, Carla
Ballesta, Sílvia
Canal, Cristina
Puig-Domingo, Manel
Granada, María Luisa
author_facet Hernández, José María
Soldevila, Berta
Velasco, Inés
Moreno-Flores, Fernando
Ferrer, Laura
Pérez-Montes de Oca, Alejandra
Santillán, Cecilia
Muñoz, Carla
Ballesta, Sílvia
Canal, Cristina
Puig-Domingo, Manel
Granada, María Luisa
author_sort Hernández, José María
collection PubMed
description Background: Recent guidelines recommend establishing a local reference interval (RI) for thyroid function. We aimed to establish trimester-specific RIs for thyrotropin (TSH) and free thyroxine (FT4) in a cohort of healthy pregnant women in Catalonia (Spain). Methods: A prospective observational study was conducted with 332 healthy pregnant women, from the first trimester (1T) to delivery. TSH was measured using an Architect(®) immunoassay (Abbott) and FT4 by two immunoassays, Architect(®) (Abbott) and Cobas(®) (Roche), in the three trimesters. FT4 was also measured by liquid chromatography mass spectrometry (LC/MS/MS) in the 1T. Results: TSH (µUI/mL) increased throughout pregnancy (1T: 0.03–3.78; 2T: 0.51–3.53; 3T: 0.50–4.32; p < 0.0001) and FT4 (pmol/L) progressively decreased (Architect(®) 1T: 10.42–15.96; 2T: 8.37–12.74; 3T: 8.24–12.49; p < 0.0001; and Cobas(®): 1T: 11.46–19.05; 2T: 9.65–14.67; 3T: 8.88–14.54; p < 0.0067). The FT4 RI during 1T determined LC/MS/MS was 8.75–18.27. Despite the 1T FT4 results measured by LC/MS/MS and with the two immunoassays being significantly correlated, the results obtained by the three methods were found to be non-interchangeable. Conclusions: We established trimester-specific RIs for TSH and for FT4 with immunoassays in our population. We also validated the 1T FT4 using LC/MS/MS to confirm the results of FT4 lower than the 2.5th percentile or higher than the 97.5th percentile.
format Online
Article
Text
id pubmed-8198941
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-81989412021-06-14 Reference Intervals of Thyroid Function Tests Assessed by Immunoassay and Mass Spectrometry in Healthy Pregnant Women Living in Catalonia Hernández, José María Soldevila, Berta Velasco, Inés Moreno-Flores, Fernando Ferrer, Laura Pérez-Montes de Oca, Alejandra Santillán, Cecilia Muñoz, Carla Ballesta, Sílvia Canal, Cristina Puig-Domingo, Manel Granada, María Luisa J Clin Med Article Background: Recent guidelines recommend establishing a local reference interval (RI) for thyroid function. We aimed to establish trimester-specific RIs for thyrotropin (TSH) and free thyroxine (FT4) in a cohort of healthy pregnant women in Catalonia (Spain). Methods: A prospective observational study was conducted with 332 healthy pregnant women, from the first trimester (1T) to delivery. TSH was measured using an Architect(®) immunoassay (Abbott) and FT4 by two immunoassays, Architect(®) (Abbott) and Cobas(®) (Roche), in the three trimesters. FT4 was also measured by liquid chromatography mass spectrometry (LC/MS/MS) in the 1T. Results: TSH (µUI/mL) increased throughout pregnancy (1T: 0.03–3.78; 2T: 0.51–3.53; 3T: 0.50–4.32; p < 0.0001) and FT4 (pmol/L) progressively decreased (Architect(®) 1T: 10.42–15.96; 2T: 8.37–12.74; 3T: 8.24–12.49; p < 0.0001; and Cobas(®): 1T: 11.46–19.05; 2T: 9.65–14.67; 3T: 8.88–14.54; p < 0.0067). The FT4 RI during 1T determined LC/MS/MS was 8.75–18.27. Despite the 1T FT4 results measured by LC/MS/MS and with the two immunoassays being significantly correlated, the results obtained by the three methods were found to be non-interchangeable. Conclusions: We established trimester-specific RIs for TSH and for FT4 with immunoassays in our population. We also validated the 1T FT4 using LC/MS/MS to confirm the results of FT4 lower than the 2.5th percentile or higher than the 97.5th percentile. MDPI 2021-05-31 /pmc/articles/PMC8198941/ /pubmed/34072898 http://dx.doi.org/10.3390/jcm10112444 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Hernández, José María
Soldevila, Berta
Velasco, Inés
Moreno-Flores, Fernando
Ferrer, Laura
Pérez-Montes de Oca, Alejandra
Santillán, Cecilia
Muñoz, Carla
Ballesta, Sílvia
Canal, Cristina
Puig-Domingo, Manel
Granada, María Luisa
Reference Intervals of Thyroid Function Tests Assessed by Immunoassay and Mass Spectrometry in Healthy Pregnant Women Living in Catalonia
title Reference Intervals of Thyroid Function Tests Assessed by Immunoassay and Mass Spectrometry in Healthy Pregnant Women Living in Catalonia
title_full Reference Intervals of Thyroid Function Tests Assessed by Immunoassay and Mass Spectrometry in Healthy Pregnant Women Living in Catalonia
title_fullStr Reference Intervals of Thyroid Function Tests Assessed by Immunoassay and Mass Spectrometry in Healthy Pregnant Women Living in Catalonia
title_full_unstemmed Reference Intervals of Thyroid Function Tests Assessed by Immunoassay and Mass Spectrometry in Healthy Pregnant Women Living in Catalonia
title_short Reference Intervals of Thyroid Function Tests Assessed by Immunoassay and Mass Spectrometry in Healthy Pregnant Women Living in Catalonia
title_sort reference intervals of thyroid function tests assessed by immunoassay and mass spectrometry in healthy pregnant women living in catalonia
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8198941/
https://www.ncbi.nlm.nih.gov/pubmed/34072898
http://dx.doi.org/10.3390/jcm10112444
work_keys_str_mv AT hernandezjosemaria referenceintervalsofthyroidfunctiontestsassessedbyimmunoassayandmassspectrometryinhealthypregnantwomenlivingincatalonia
AT soldevilaberta referenceintervalsofthyroidfunctiontestsassessedbyimmunoassayandmassspectrometryinhealthypregnantwomenlivingincatalonia
AT velascoines referenceintervalsofthyroidfunctiontestsassessedbyimmunoassayandmassspectrometryinhealthypregnantwomenlivingincatalonia
AT morenofloresfernando referenceintervalsofthyroidfunctiontestsassessedbyimmunoassayandmassspectrometryinhealthypregnantwomenlivingincatalonia
AT ferrerlaura referenceintervalsofthyroidfunctiontestsassessedbyimmunoassayandmassspectrometryinhealthypregnantwomenlivingincatalonia
AT perezmontesdeocaalejandra referenceintervalsofthyroidfunctiontestsassessedbyimmunoassayandmassspectrometryinhealthypregnantwomenlivingincatalonia
AT santillancecilia referenceintervalsofthyroidfunctiontestsassessedbyimmunoassayandmassspectrometryinhealthypregnantwomenlivingincatalonia
AT munozcarla referenceintervalsofthyroidfunctiontestsassessedbyimmunoassayandmassspectrometryinhealthypregnantwomenlivingincatalonia
AT ballestasilvia referenceintervalsofthyroidfunctiontestsassessedbyimmunoassayandmassspectrometryinhealthypregnantwomenlivingincatalonia
AT canalcristina referenceintervalsofthyroidfunctiontestsassessedbyimmunoassayandmassspectrometryinhealthypregnantwomenlivingincatalonia
AT puigdomingomanel referenceintervalsofthyroidfunctiontestsassessedbyimmunoassayandmassspectrometryinhealthypregnantwomenlivingincatalonia
AT granadamarialuisa referenceintervalsofthyroidfunctiontestsassessedbyimmunoassayandmassspectrometryinhealthypregnantwomenlivingincatalonia