Cargando…
Determination of Load-Carrying Capacity of C-Profile Glued Ti-Al Column under Temperature Environment
The paper deals with an examination of the behaviour of glued Ti-Al column under compression at elevated temperature. The tests of compressed columns with initial load were performed at different temperatures to obtain their characteristics and the load-carrying capacity. The deformations of columns...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8199520/ https://www.ncbi.nlm.nih.gov/pubmed/34199364 http://dx.doi.org/10.3390/ma14113013 |
_version_ | 1783707396505337856 |
---|---|
author | Czechowski, Leszek |
author_facet | Czechowski, Leszek |
author_sort | Czechowski, Leszek |
collection | PubMed |
description | The paper deals with an examination of the behaviour of glued Ti-Al column under compression at elevated temperature. The tests of compressed columns with initial load were performed at different temperatures to obtain their characteristics and the load-carrying capacity. The deformations of columns during tests were registered by employing non-contact Digital Image Correlation Aramis(®) System. The numerical computations based on finite element method by using two different discrete models were carried out to validate the empirical results. To solve the problems, true stress-logarithmic strain curves of one-directional tensile tests dependent on temperature both for considered metals and glue were implemented to software. Numerical estimations based on Green–Lagrange equations for large deflections and strains were conducted. The paper reveals the influence of temperature on the behaviour of compressed C-profile Ti-Al columns. It was verified how the load-carrying capacity of glued bi-metal column decreases with an increase in the temperature increment. The achieved maximum loads at temperature 200 °C dropped by 2.5 times related to maximum loads at ambient temperature. |
format | Online Article Text |
id | pubmed-8199520 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-81995202021-06-14 Determination of Load-Carrying Capacity of C-Profile Glued Ti-Al Column under Temperature Environment Czechowski, Leszek Materials (Basel) Article The paper deals with an examination of the behaviour of glued Ti-Al column under compression at elevated temperature. The tests of compressed columns with initial load were performed at different temperatures to obtain their characteristics and the load-carrying capacity. The deformations of columns during tests were registered by employing non-contact Digital Image Correlation Aramis(®) System. The numerical computations based on finite element method by using two different discrete models were carried out to validate the empirical results. To solve the problems, true stress-logarithmic strain curves of one-directional tensile tests dependent on temperature both for considered metals and glue were implemented to software. Numerical estimations based on Green–Lagrange equations for large deflections and strains were conducted. The paper reveals the influence of temperature on the behaviour of compressed C-profile Ti-Al columns. It was verified how the load-carrying capacity of glued bi-metal column decreases with an increase in the temperature increment. The achieved maximum loads at temperature 200 °C dropped by 2.5 times related to maximum loads at ambient temperature. MDPI 2021-06-02 /pmc/articles/PMC8199520/ /pubmed/34199364 http://dx.doi.org/10.3390/ma14113013 Text en © 2021 by the author. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Czechowski, Leszek Determination of Load-Carrying Capacity of C-Profile Glued Ti-Al Column under Temperature Environment |
title | Determination of Load-Carrying Capacity of C-Profile Glued Ti-Al Column under Temperature Environment |
title_full | Determination of Load-Carrying Capacity of C-Profile Glued Ti-Al Column under Temperature Environment |
title_fullStr | Determination of Load-Carrying Capacity of C-Profile Glued Ti-Al Column under Temperature Environment |
title_full_unstemmed | Determination of Load-Carrying Capacity of C-Profile Glued Ti-Al Column under Temperature Environment |
title_short | Determination of Load-Carrying Capacity of C-Profile Glued Ti-Al Column under Temperature Environment |
title_sort | determination of load-carrying capacity of c-profile glued ti-al column under temperature environment |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8199520/ https://www.ncbi.nlm.nih.gov/pubmed/34199364 http://dx.doi.org/10.3390/ma14113013 |
work_keys_str_mv | AT czechowskileszek determinationofloadcarryingcapacityofcprofilegluedtialcolumnundertemperatureenvironment |