Determination of Load-Carrying Capacity of C-Profile Glued Ti-Al Column under Temperature Environment

The paper deals with an examination of the behaviour of glued Ti-Al column under compression at elevated temperature. The tests of compressed columns with initial load were performed at different temperatures to obtain their characteristics and the load-carrying capacity. The deformations of columns...

Descripción completa

Detalles Bibliográficos
Autor principal: Czechowski, Leszek
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8199520/
https://www.ncbi.nlm.nih.gov/pubmed/34199364
http://dx.doi.org/10.3390/ma14113013
_version_ 1783707396505337856
author Czechowski, Leszek
author_facet Czechowski, Leszek
author_sort Czechowski, Leszek
collection PubMed
description The paper deals with an examination of the behaviour of glued Ti-Al column under compression at elevated temperature. The tests of compressed columns with initial load were performed at different temperatures to obtain their characteristics and the load-carrying capacity. The deformations of columns during tests were registered by employing non-contact Digital Image Correlation Aramis(®) System. The numerical computations based on finite element method by using two different discrete models were carried out to validate the empirical results. To solve the problems, true stress-logarithmic strain curves of one-directional tensile tests dependent on temperature both for considered metals and glue were implemented to software. Numerical estimations based on Green–Lagrange equations for large deflections and strains were conducted. The paper reveals the influence of temperature on the behaviour of compressed C-profile Ti-Al columns. It was verified how the load-carrying capacity of glued bi-metal column decreases with an increase in the temperature increment. The achieved maximum loads at temperature 200 °C dropped by 2.5 times related to maximum loads at ambient temperature.
format Online
Article
Text
id pubmed-8199520
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-81995202021-06-14 Determination of Load-Carrying Capacity of C-Profile Glued Ti-Al Column under Temperature Environment Czechowski, Leszek Materials (Basel) Article The paper deals with an examination of the behaviour of glued Ti-Al column under compression at elevated temperature. The tests of compressed columns with initial load were performed at different temperatures to obtain their characteristics and the load-carrying capacity. The deformations of columns during tests were registered by employing non-contact Digital Image Correlation Aramis(®) System. The numerical computations based on finite element method by using two different discrete models were carried out to validate the empirical results. To solve the problems, true stress-logarithmic strain curves of one-directional tensile tests dependent on temperature both for considered metals and glue were implemented to software. Numerical estimations based on Green–Lagrange equations for large deflections and strains were conducted. The paper reveals the influence of temperature on the behaviour of compressed C-profile Ti-Al columns. It was verified how the load-carrying capacity of glued bi-metal column decreases with an increase in the temperature increment. The achieved maximum loads at temperature 200 °C dropped by 2.5 times related to maximum loads at ambient temperature. MDPI 2021-06-02 /pmc/articles/PMC8199520/ /pubmed/34199364 http://dx.doi.org/10.3390/ma14113013 Text en © 2021 by the author. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Czechowski, Leszek
Determination of Load-Carrying Capacity of C-Profile Glued Ti-Al Column under Temperature Environment
title Determination of Load-Carrying Capacity of C-Profile Glued Ti-Al Column under Temperature Environment
title_full Determination of Load-Carrying Capacity of C-Profile Glued Ti-Al Column under Temperature Environment
title_fullStr Determination of Load-Carrying Capacity of C-Profile Glued Ti-Al Column under Temperature Environment
title_full_unstemmed Determination of Load-Carrying Capacity of C-Profile Glued Ti-Al Column under Temperature Environment
title_short Determination of Load-Carrying Capacity of C-Profile Glued Ti-Al Column under Temperature Environment
title_sort determination of load-carrying capacity of c-profile glued ti-al column under temperature environment
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8199520/
https://www.ncbi.nlm.nih.gov/pubmed/34199364
http://dx.doi.org/10.3390/ma14113013
work_keys_str_mv AT czechowskileszek determinationofloadcarryingcapacityofcprofilegluedtialcolumnundertemperatureenvironment