Capillary Sensor for Detection of Amphetamine Precursors in Sewage Water

This paper deals with the problem of detecting benzyl methyl ketone (BMK), which is a precursor of amphetamine that can be synthesized in home labs. The focus of our work was to identify an improvement for the analysis of sewage introduced into the municipal sewage system. The sensors used to detect...

Descripción completa

Detalles Bibliográficos
Autores principales: Wiśnik-Sawka, Monika, Maziejuk, Mirosław, Fabianowski, Wojciech, Karpińska, Urszula, Szwast, Maciej, Weremczuk, Jerzy
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8199614/
https://www.ncbi.nlm.nih.gov/pubmed/34199443
http://dx.doi.org/10.3390/polym13111846
Descripción
Sumario:This paper deals with the problem of detecting benzyl methyl ketone (BMK), which is a precursor of amphetamine that can be synthesized in home labs. The focus of our work was to identify an improvement for the analysis of sewage introduced into the municipal sewage system. The sensors used to detect BKM in these systems are often clogged and therefore cannot function properly. In this article, a new method of detecting BMK and other chemicals in wastewater is presented. A system containing capillary polypropylene, hydrophobized with polysiloxane coating fibers was prepared. These solutions were used for continuous online measurements by ion mobility spectrometry. The use of pipes with a polysiloxane coating reduces the permeation of water and significantly increases the BMK permeation due to its high solubility in the polymer.