Diagnostically Oriented Experiments and Modelling of Switched Reluctance Motor Dynamic Eccentricity

The article compares the results of experimental and modelling research of switched reluctance motor at two different operational states: one proper and one with mechanical fault, i.e., with dynamic eccentricity of the rotor. The experiments were carried out on a test bench and then the results were...

Descripción completa

Detalles Bibliográficos
Autores principales: Lorencki, Jakub, Radkowski, Stanisław, Gontarz, Szymon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8199709/
https://www.ncbi.nlm.nih.gov/pubmed/34204882
http://dx.doi.org/10.3390/s21113857
_version_ 1783707440974397440
author Lorencki, Jakub
Radkowski, Stanisław
Gontarz, Szymon
author_facet Lorencki, Jakub
Radkowski, Stanisław
Gontarz, Szymon
author_sort Lorencki, Jakub
collection PubMed
description The article compares the results of experimental and modelling research of switched reluctance motor at two different operational states: one proper and one with mechanical fault, i.e., with dynamic eccentricity of the rotor. The experiments were carried out on a test bench and then the results were compared with mathematical modelling of quasi-static and dynamic analysis of 2D geometry model. Finally, it was examined how the operation with dynamic eccentricity fault of the motor affected its main physical parameter—the phase current. The analysis was presented in the frequency domain using the Fast Fourier Transform (FFT); however, individual current waveforms in the time domain are also shown for comparison. Applying results of the research could increase reliability of the maintenance of SRM and enhance its application in vehicles for special purposes as well as its military and industrial applications.
format Online
Article
Text
id pubmed-8199709
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-81997092021-06-14 Diagnostically Oriented Experiments and Modelling of Switched Reluctance Motor Dynamic Eccentricity Lorencki, Jakub Radkowski, Stanisław Gontarz, Szymon Sensors (Basel) Communication The article compares the results of experimental and modelling research of switched reluctance motor at two different operational states: one proper and one with mechanical fault, i.e., with dynamic eccentricity of the rotor. The experiments were carried out on a test bench and then the results were compared with mathematical modelling of quasi-static and dynamic analysis of 2D geometry model. Finally, it was examined how the operation with dynamic eccentricity fault of the motor affected its main physical parameter—the phase current. The analysis was presented in the frequency domain using the Fast Fourier Transform (FFT); however, individual current waveforms in the time domain are also shown for comparison. Applying results of the research could increase reliability of the maintenance of SRM and enhance its application in vehicles for special purposes as well as its military and industrial applications. MDPI 2021-06-03 /pmc/articles/PMC8199709/ /pubmed/34204882 http://dx.doi.org/10.3390/s21113857 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Communication
Lorencki, Jakub
Radkowski, Stanisław
Gontarz, Szymon
Diagnostically Oriented Experiments and Modelling of Switched Reluctance Motor Dynamic Eccentricity
title Diagnostically Oriented Experiments and Modelling of Switched Reluctance Motor Dynamic Eccentricity
title_full Diagnostically Oriented Experiments and Modelling of Switched Reluctance Motor Dynamic Eccentricity
title_fullStr Diagnostically Oriented Experiments and Modelling of Switched Reluctance Motor Dynamic Eccentricity
title_full_unstemmed Diagnostically Oriented Experiments and Modelling of Switched Reluctance Motor Dynamic Eccentricity
title_short Diagnostically Oriented Experiments and Modelling of Switched Reluctance Motor Dynamic Eccentricity
title_sort diagnostically oriented experiments and modelling of switched reluctance motor dynamic eccentricity
topic Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8199709/
https://www.ncbi.nlm.nih.gov/pubmed/34204882
http://dx.doi.org/10.3390/s21113857
work_keys_str_mv AT lorenckijakub diagnosticallyorientedexperimentsandmodellingofswitchedreluctancemotordynamiceccentricity
AT radkowskistanisław diagnosticallyorientedexperimentsandmodellingofswitchedreluctancemotordynamiceccentricity
AT gontarzszymon diagnosticallyorientedexperimentsandmodellingofswitchedreluctancemotordynamiceccentricity