Cargando…

Muscle shear wave elastography, conventional B mode and power doppler ultrasonography in healthy adults and patients with autoimmune inflammatory myopathies: a pilot cross-sectional study

BACKGROUND: Before the role of shear wave elastography (SWE) and B mode ultrasound (US) in the diagnosis of different forms of idiopathic inflammatory myopathies (IIM) can be investigated, normative data is required. This study aimed to describe and then compare normative SWE and B mode ultrasound m...

Descripción completa

Detalles Bibliográficos
Autores principales: Paramalingam, Shereen, Needham, Merrilee, Raymond, Warren, Mastaglia, Frank, Lightowler, Daniel, Morin, Narelle, Counsel, Peter, Keen, Helen Isobel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8199828/
https://www.ncbi.nlm.nih.gov/pubmed/34118902
http://dx.doi.org/10.1186/s12891-021-04424-0
_version_ 1783707467869323264
author Paramalingam, Shereen
Needham, Merrilee
Raymond, Warren
Mastaglia, Frank
Lightowler, Daniel
Morin, Narelle
Counsel, Peter
Keen, Helen Isobel
author_facet Paramalingam, Shereen
Needham, Merrilee
Raymond, Warren
Mastaglia, Frank
Lightowler, Daniel
Morin, Narelle
Counsel, Peter
Keen, Helen Isobel
author_sort Paramalingam, Shereen
collection PubMed
description BACKGROUND: Before the role of shear wave elastography (SWE) and B mode ultrasound (US) in the diagnosis of different forms of idiopathic inflammatory myopathies (IIM) can be investigated, normative data is required. This study aimed to describe and then compare normative SWE and B mode ultrasound metrics of muscles in healthy controls and patients with IIM. METHODS: Twenty nine healthy adult controls and 10 IIM patients (5 with inclusion body myositis and 5 with necrotising autoimmune myopathy) underwent a full clinical examination, laboratory investigations, SWE and US measurements of selected proximal and distal limb muscles. Shear wave speed (SWS) and multiple US domains [echogenicity, fascial thickness, muscle bulk and power Doppler (PD)] were measured in both groups. RESULTS: In healthy controls (n = 29; mean age 46.60 ± 16.10; 44.8 % female), age was inversely correlated with SWS at the deltoid (stretch) (Rs. -0.40, p = 0.030) and PD score at the deltoid (rest) (Rs. -0.40, P = 0.032). Those ≥ 50 years old had a lower SWS at the deltoid (stretch) compared to the < 50 year group (2.92 m/s vs. 2.40 m/s, P = 0.032). Age correlated with increased echogenicity in the flexor digitorum profundus (Rs. 0.38, P = 0.045). Females had a smaller muscle bulk in the deltoid (P = 0.022). Body mass index (BMI) was inversely associated with SWS in the deltoid (stretch) (Rs – 0.45, P = 0.026), and positively correlated with echogenicity in the deltoid (Rs. 0.69, P = 0.026). In patients ≥50 years of age, patients with IIM (mean age 61.00 ± 8.18; females 20.0 %) had a higher proportion of abnormal echogenicity scores at the flexor digitorum profundus (FDP) (40.00 % vs. 14.30 %, P = 0.022) and tibialis anterior (TA) (80.00 % vs. 28.60 %, P = 0.004). Fascial thickness was lower in the FDP (0.63mm vs. 0.50mm, p = 0.012) and TA (0.58mm vs. 0.45mm, P = 0.001). CONCLUSIONS: Our findings suggest there is scope for US techniques to be useful for diagnostic screening of affected muscles in patients with IIM, especially in those with suspected inclusion body myositis or necrotising autoimmune myopathy. We provide normative data for future studies into SWE and US techniques in skeletal muscle. The differences between IIM patients and controls warrant further study in a broader IIM patient cohort. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12891-021-04424-0.
format Online
Article
Text
id pubmed-8199828
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-81998282021-06-15 Muscle shear wave elastography, conventional B mode and power doppler ultrasonography in healthy adults and patients with autoimmune inflammatory myopathies: a pilot cross-sectional study Paramalingam, Shereen Needham, Merrilee Raymond, Warren Mastaglia, Frank Lightowler, Daniel Morin, Narelle Counsel, Peter Keen, Helen Isobel BMC Musculoskelet Disord Research BACKGROUND: Before the role of shear wave elastography (SWE) and B mode ultrasound (US) in the diagnosis of different forms of idiopathic inflammatory myopathies (IIM) can be investigated, normative data is required. This study aimed to describe and then compare normative SWE and B mode ultrasound metrics of muscles in healthy controls and patients with IIM. METHODS: Twenty nine healthy adult controls and 10 IIM patients (5 with inclusion body myositis and 5 with necrotising autoimmune myopathy) underwent a full clinical examination, laboratory investigations, SWE and US measurements of selected proximal and distal limb muscles. Shear wave speed (SWS) and multiple US domains [echogenicity, fascial thickness, muscle bulk and power Doppler (PD)] were measured in both groups. RESULTS: In healthy controls (n = 29; mean age 46.60 ± 16.10; 44.8 % female), age was inversely correlated with SWS at the deltoid (stretch) (Rs. -0.40, p = 0.030) and PD score at the deltoid (rest) (Rs. -0.40, P = 0.032). Those ≥ 50 years old had a lower SWS at the deltoid (stretch) compared to the < 50 year group (2.92 m/s vs. 2.40 m/s, P = 0.032). Age correlated with increased echogenicity in the flexor digitorum profundus (Rs. 0.38, P = 0.045). Females had a smaller muscle bulk in the deltoid (P = 0.022). Body mass index (BMI) was inversely associated with SWS in the deltoid (stretch) (Rs – 0.45, P = 0.026), and positively correlated with echogenicity in the deltoid (Rs. 0.69, P = 0.026). In patients ≥50 years of age, patients with IIM (mean age 61.00 ± 8.18; females 20.0 %) had a higher proportion of abnormal echogenicity scores at the flexor digitorum profundus (FDP) (40.00 % vs. 14.30 %, P = 0.022) and tibialis anterior (TA) (80.00 % vs. 28.60 %, P = 0.004). Fascial thickness was lower in the FDP (0.63mm vs. 0.50mm, p = 0.012) and TA (0.58mm vs. 0.45mm, P = 0.001). CONCLUSIONS: Our findings suggest there is scope for US techniques to be useful for diagnostic screening of affected muscles in patients with IIM, especially in those with suspected inclusion body myositis or necrotising autoimmune myopathy. We provide normative data for future studies into SWE and US techniques in skeletal muscle. The differences between IIM patients and controls warrant further study in a broader IIM patient cohort. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12891-021-04424-0. BioMed Central 2021-06-12 /pmc/articles/PMC8199828/ /pubmed/34118902 http://dx.doi.org/10.1186/s12891-021-04424-0 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Paramalingam, Shereen
Needham, Merrilee
Raymond, Warren
Mastaglia, Frank
Lightowler, Daniel
Morin, Narelle
Counsel, Peter
Keen, Helen Isobel
Muscle shear wave elastography, conventional B mode and power doppler ultrasonography in healthy adults and patients with autoimmune inflammatory myopathies: a pilot cross-sectional study
title Muscle shear wave elastography, conventional B mode and power doppler ultrasonography in healthy adults and patients with autoimmune inflammatory myopathies: a pilot cross-sectional study
title_full Muscle shear wave elastography, conventional B mode and power doppler ultrasonography in healthy adults and patients with autoimmune inflammatory myopathies: a pilot cross-sectional study
title_fullStr Muscle shear wave elastography, conventional B mode and power doppler ultrasonography in healthy adults and patients with autoimmune inflammatory myopathies: a pilot cross-sectional study
title_full_unstemmed Muscle shear wave elastography, conventional B mode and power doppler ultrasonography in healthy adults and patients with autoimmune inflammatory myopathies: a pilot cross-sectional study
title_short Muscle shear wave elastography, conventional B mode and power doppler ultrasonography in healthy adults and patients with autoimmune inflammatory myopathies: a pilot cross-sectional study
title_sort muscle shear wave elastography, conventional b mode and power doppler ultrasonography in healthy adults and patients with autoimmune inflammatory myopathies: a pilot cross-sectional study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8199828/
https://www.ncbi.nlm.nih.gov/pubmed/34118902
http://dx.doi.org/10.1186/s12891-021-04424-0
work_keys_str_mv AT paramalingamshereen muscleshearwaveelastographyconventionalbmodeandpowerdopplerultrasonographyinhealthyadultsandpatientswithautoimmuneinflammatorymyopathiesapilotcrosssectionalstudy
AT needhammerrilee muscleshearwaveelastographyconventionalbmodeandpowerdopplerultrasonographyinhealthyadultsandpatientswithautoimmuneinflammatorymyopathiesapilotcrosssectionalstudy
AT raymondwarren muscleshearwaveelastographyconventionalbmodeandpowerdopplerultrasonographyinhealthyadultsandpatientswithautoimmuneinflammatorymyopathiesapilotcrosssectionalstudy
AT mastagliafrank muscleshearwaveelastographyconventionalbmodeandpowerdopplerultrasonographyinhealthyadultsandpatientswithautoimmuneinflammatorymyopathiesapilotcrosssectionalstudy
AT lightowlerdaniel muscleshearwaveelastographyconventionalbmodeandpowerdopplerultrasonographyinhealthyadultsandpatientswithautoimmuneinflammatorymyopathiesapilotcrosssectionalstudy
AT morinnarelle muscleshearwaveelastographyconventionalbmodeandpowerdopplerultrasonographyinhealthyadultsandpatientswithautoimmuneinflammatorymyopathiesapilotcrosssectionalstudy
AT counselpeter muscleshearwaveelastographyconventionalbmodeandpowerdopplerultrasonographyinhealthyadultsandpatientswithautoimmuneinflammatorymyopathiesapilotcrosssectionalstudy
AT keenhelenisobel muscleshearwaveelastographyconventionalbmodeandpowerdopplerultrasonographyinhealthyadultsandpatientswithautoimmuneinflammatorymyopathiesapilotcrosssectionalstudy