Cargando…

Time-Variant Positive Air Pressure in Drainage Stacks as a Pathogen Transmission Pathway of COVID-19

Time-variant positive air pressure in a drainage stack poses a risk of pathogenic virus transmission into a habitable space, however, the excessive risk and its significance have not yet been sufficiently addressed for drainage system designs. This study proposes a novel measure for the probable pat...

Descripción completa

Detalles Bibliográficos
Autores principales: Wong, Ling-Tim, Mui, Kwok-Wai, Cheng, Cheng-Li, Leung, Polly Hang-Mei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8200215/
https://www.ncbi.nlm.nih.gov/pubmed/34199937
http://dx.doi.org/10.3390/ijerph18116068
_version_ 1783707559774912512
author Wong, Ling-Tim
Mui, Kwok-Wai
Cheng, Cheng-Li
Leung, Polly Hang-Mei
author_facet Wong, Ling-Tim
Mui, Kwok-Wai
Cheng, Cheng-Li
Leung, Polly Hang-Mei
author_sort Wong, Ling-Tim
collection PubMed
description Time-variant positive air pressure in a drainage stack poses a risk of pathogenic virus transmission into a habitable space, however, the excessive risk and its significance have not yet been sufficiently addressed for drainage system designs. This study proposes a novel measure for the probable pathogenic virus transmission risk of a high-rise drainage stack with the occurrence of positive air pressure. The proposed approach is based on time-variant positive air pressures measured in a 38 m high drainage stack of a full-scale experimental tower under steady flow conditions of flow rate 1–4 Ls(−1) discharging at a height between 15 m to 33 m above the stack base. The maximum pressure and probabilistic positive air pressures in the discharging stack ventilation section with no water (Zone A of the discharging drainage stack) were determined. It was demonstrated that the positive air pressures were lower in frequency as compared with those in other stack zones and could propagate along the upper 1/3 portion of the ventilation pipe (H’ ≥ 0.63) towards the ventilation opening at the rooftop. As the probabilistic positive pressures at a stack height were found to be related to the water discharging height and flow rate, a risk model of positive air pressure is proposed. Taking the 119th, 124th, 140th and 11,547th COVID-19 cases of an epidemiological investigation in Hong Kong as a baseline of concern, excessive risk of system overuse was evaluated. The results showed that for a 20–80% increase in the frequency of discharge flow rate, the number of floors identified at risk increased from 1 to 9 and 1 to 6 in the 34- and 25-storey residential buildings, respectively. The outcome can apply to facilities planning for self-quarantine arrangements in high-rise buildings where pathogenic virus transmission associated with drainage system overuse is a concern.
format Online
Article
Text
id pubmed-8200215
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-82002152021-06-14 Time-Variant Positive Air Pressure in Drainage Stacks as a Pathogen Transmission Pathway of COVID-19 Wong, Ling-Tim Mui, Kwok-Wai Cheng, Cheng-Li Leung, Polly Hang-Mei Int J Environ Res Public Health Article Time-variant positive air pressure in a drainage stack poses a risk of pathogenic virus transmission into a habitable space, however, the excessive risk and its significance have not yet been sufficiently addressed for drainage system designs. This study proposes a novel measure for the probable pathogenic virus transmission risk of a high-rise drainage stack with the occurrence of positive air pressure. The proposed approach is based on time-variant positive air pressures measured in a 38 m high drainage stack of a full-scale experimental tower under steady flow conditions of flow rate 1–4 Ls(−1) discharging at a height between 15 m to 33 m above the stack base. The maximum pressure and probabilistic positive air pressures in the discharging stack ventilation section with no water (Zone A of the discharging drainage stack) were determined. It was demonstrated that the positive air pressures were lower in frequency as compared with those in other stack zones and could propagate along the upper 1/3 portion of the ventilation pipe (H’ ≥ 0.63) towards the ventilation opening at the rooftop. As the probabilistic positive pressures at a stack height were found to be related to the water discharging height and flow rate, a risk model of positive air pressure is proposed. Taking the 119th, 124th, 140th and 11,547th COVID-19 cases of an epidemiological investigation in Hong Kong as a baseline of concern, excessive risk of system overuse was evaluated. The results showed that for a 20–80% increase in the frequency of discharge flow rate, the number of floors identified at risk increased from 1 to 9 and 1 to 6 in the 34- and 25-storey residential buildings, respectively. The outcome can apply to facilities planning for self-quarantine arrangements in high-rise buildings where pathogenic virus transmission associated with drainage system overuse is a concern. MDPI 2021-06-04 /pmc/articles/PMC8200215/ /pubmed/34199937 http://dx.doi.org/10.3390/ijerph18116068 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Wong, Ling-Tim
Mui, Kwok-Wai
Cheng, Cheng-Li
Leung, Polly Hang-Mei
Time-Variant Positive Air Pressure in Drainage Stacks as a Pathogen Transmission Pathway of COVID-19
title Time-Variant Positive Air Pressure in Drainage Stacks as a Pathogen Transmission Pathway of COVID-19
title_full Time-Variant Positive Air Pressure in Drainage Stacks as a Pathogen Transmission Pathway of COVID-19
title_fullStr Time-Variant Positive Air Pressure in Drainage Stacks as a Pathogen Transmission Pathway of COVID-19
title_full_unstemmed Time-Variant Positive Air Pressure in Drainage Stacks as a Pathogen Transmission Pathway of COVID-19
title_short Time-Variant Positive Air Pressure in Drainage Stacks as a Pathogen Transmission Pathway of COVID-19
title_sort time-variant positive air pressure in drainage stacks as a pathogen transmission pathway of covid-19
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8200215/
https://www.ncbi.nlm.nih.gov/pubmed/34199937
http://dx.doi.org/10.3390/ijerph18116068
work_keys_str_mv AT wonglingtim timevariantpositiveairpressureindrainagestacksasapathogentransmissionpathwayofcovid19
AT muikwokwai timevariantpositiveairpressureindrainagestacksasapathogentransmissionpathwayofcovid19
AT chengchengli timevariantpositiveairpressureindrainagestacksasapathogentransmissionpathwayofcovid19
AT leungpollyhangmei timevariantpositiveairpressureindrainagestacksasapathogentransmissionpathwayofcovid19