Cargando…

Accuracy of registration techniques and vascular imaging modalities in fusion imaging for aortic endovascular interventions: a phantom study

BACKGROUND: This study aimed to assess the error of different registration techniques and imaging modalities for fusion imaging of the aorta in a standardized setting using a anthropomorphic body phantom. MATERIALS AND METHODS: A phantom with the 3D printed vasculature of a patient suffering from an...

Descripción completa

Detalles Bibliográficos
Autores principales: Sieren, M. M., Schareck, C., Kaschwich, M., Horn, M., Matysiak, F., Stahlberg, E., Wegner, F., Oechtering, T. H., Barkhausen, J., Goltz, J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8200901/
https://www.ncbi.nlm.nih.gov/pubmed/34125287
http://dx.doi.org/10.1186/s42155-021-00234-6
_version_ 1783707697228546048
author Sieren, M. M.
Schareck, C.
Kaschwich, M.
Horn, M.
Matysiak, F.
Stahlberg, E.
Wegner, F.
Oechtering, T. H.
Barkhausen, J.
Goltz, J.
author_facet Sieren, M. M.
Schareck, C.
Kaschwich, M.
Horn, M.
Matysiak, F.
Stahlberg, E.
Wegner, F.
Oechtering, T. H.
Barkhausen, J.
Goltz, J.
author_sort Sieren, M. M.
collection PubMed
description BACKGROUND: This study aimed to assess the error of different registration techniques and imaging modalities for fusion imaging of the aorta in a standardized setting using a anthropomorphic body phantom. MATERIALS AND METHODS: A phantom with the 3D printed vasculature of a patient suffering from an infrarenal aortic aneurysm was constructed. Pulsatile flow was generated via an external pump. CTA/MRA of the phantom was performed, and a virtual 3D vascular model was computed. Subsequently, fusion imaging was performed employing 3D-3D and 2D-3D registration techniques. Accuracy of the registration was evaluated from 7 right/left anterior oblique c-arm angulations using the agreement of centerlines and landmarks between the phantom vessels and the virtual 3D virtual vascular model. Differences between imaging modalities were assessed in a head-to-head comparison based on centerline deviation. Statistics included the comparison of means ± standard deviations, student’s t-test, Bland-Altman analysis, and intraclass correlation coefficient for intra- and inter-reader analysis. RESULTS: 3D-3D registration was superior to 2D-3D registration, with the highest mean centerline deviation being 1.67 ± 0.24 mm compared to 4.47 ± 0.92 mm. The highest absolute deviation was 3.25 mm for 3D-3D and 6.25 mm for 2D-3D registration. Differences for all angulations between registration techniques reached statistical significance. A decrease in registration accuracy was observed for c-arm angulations beyond 30° right anterior oblique/left anterior oblique. All landmarks (100%) were correctly positioned using 3D-3D registration compared to 81% using 2D-3D registration. Differences in accuracy between CT and MRI were acceptably small. Intra- and inter-reader reliability was excellent. CONCLUSION: In the realm of registration techniques, the 3D-3D method proved more accurate than did the 2D-3D method. Based on our data, the use of 2D-3D registration for interventions with high registration quality requirements (e.g., fenestrated aortic repair procedures) cannot be fully recommended. Regarding imaging modalities, CTA and MRA can be used equivalently.
format Online
Article
Text
id pubmed-8200901
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-82009012021-06-28 Accuracy of registration techniques and vascular imaging modalities in fusion imaging for aortic endovascular interventions: a phantom study Sieren, M. M. Schareck, C. Kaschwich, M. Horn, M. Matysiak, F. Stahlberg, E. Wegner, F. Oechtering, T. H. Barkhausen, J. Goltz, J. CVIR Endovasc Original Article BACKGROUND: This study aimed to assess the error of different registration techniques and imaging modalities for fusion imaging of the aorta in a standardized setting using a anthropomorphic body phantom. MATERIALS AND METHODS: A phantom with the 3D printed vasculature of a patient suffering from an infrarenal aortic aneurysm was constructed. Pulsatile flow was generated via an external pump. CTA/MRA of the phantom was performed, and a virtual 3D vascular model was computed. Subsequently, fusion imaging was performed employing 3D-3D and 2D-3D registration techniques. Accuracy of the registration was evaluated from 7 right/left anterior oblique c-arm angulations using the agreement of centerlines and landmarks between the phantom vessels and the virtual 3D virtual vascular model. Differences between imaging modalities were assessed in a head-to-head comparison based on centerline deviation. Statistics included the comparison of means ± standard deviations, student’s t-test, Bland-Altman analysis, and intraclass correlation coefficient for intra- and inter-reader analysis. RESULTS: 3D-3D registration was superior to 2D-3D registration, with the highest mean centerline deviation being 1.67 ± 0.24 mm compared to 4.47 ± 0.92 mm. The highest absolute deviation was 3.25 mm for 3D-3D and 6.25 mm for 2D-3D registration. Differences for all angulations between registration techniques reached statistical significance. A decrease in registration accuracy was observed for c-arm angulations beyond 30° right anterior oblique/left anterior oblique. All landmarks (100%) were correctly positioned using 3D-3D registration compared to 81% using 2D-3D registration. Differences in accuracy between CT and MRI were acceptably small. Intra- and inter-reader reliability was excellent. CONCLUSION: In the realm of registration techniques, the 3D-3D method proved more accurate than did the 2D-3D method. Based on our data, the use of 2D-3D registration for interventions with high registration quality requirements (e.g., fenestrated aortic repair procedures) cannot be fully recommended. Regarding imaging modalities, CTA and MRA can be used equivalently. Springer International Publishing 2021-06-14 /pmc/articles/PMC8200901/ /pubmed/34125287 http://dx.doi.org/10.1186/s42155-021-00234-6 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Sieren, M. M.
Schareck, C.
Kaschwich, M.
Horn, M.
Matysiak, F.
Stahlberg, E.
Wegner, F.
Oechtering, T. H.
Barkhausen, J.
Goltz, J.
Accuracy of registration techniques and vascular imaging modalities in fusion imaging for aortic endovascular interventions: a phantom study
title Accuracy of registration techniques and vascular imaging modalities in fusion imaging for aortic endovascular interventions: a phantom study
title_full Accuracy of registration techniques and vascular imaging modalities in fusion imaging for aortic endovascular interventions: a phantom study
title_fullStr Accuracy of registration techniques and vascular imaging modalities in fusion imaging for aortic endovascular interventions: a phantom study
title_full_unstemmed Accuracy of registration techniques and vascular imaging modalities in fusion imaging for aortic endovascular interventions: a phantom study
title_short Accuracy of registration techniques and vascular imaging modalities in fusion imaging for aortic endovascular interventions: a phantom study
title_sort accuracy of registration techniques and vascular imaging modalities in fusion imaging for aortic endovascular interventions: a phantom study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8200901/
https://www.ncbi.nlm.nih.gov/pubmed/34125287
http://dx.doi.org/10.1186/s42155-021-00234-6
work_keys_str_mv AT sierenmm accuracyofregistrationtechniquesandvascularimagingmodalitiesinfusionimagingforaorticendovascularinterventionsaphantomstudy
AT schareckc accuracyofregistrationtechniquesandvascularimagingmodalitiesinfusionimagingforaorticendovascularinterventionsaphantomstudy
AT kaschwichm accuracyofregistrationtechniquesandvascularimagingmodalitiesinfusionimagingforaorticendovascularinterventionsaphantomstudy
AT hornm accuracyofregistrationtechniquesandvascularimagingmodalitiesinfusionimagingforaorticendovascularinterventionsaphantomstudy
AT matysiakf accuracyofregistrationtechniquesandvascularimagingmodalitiesinfusionimagingforaorticendovascularinterventionsaphantomstudy
AT stahlberge accuracyofregistrationtechniquesandvascularimagingmodalitiesinfusionimagingforaorticendovascularinterventionsaphantomstudy
AT wegnerf accuracyofregistrationtechniquesandvascularimagingmodalitiesinfusionimagingforaorticendovascularinterventionsaphantomstudy
AT oechteringth accuracyofregistrationtechniquesandvascularimagingmodalitiesinfusionimagingforaorticendovascularinterventionsaphantomstudy
AT barkhausenj accuracyofregistrationtechniquesandvascularimagingmodalitiesinfusionimagingforaorticendovascularinterventionsaphantomstudy
AT goltzj accuracyofregistrationtechniquesandvascularimagingmodalitiesinfusionimagingforaorticendovascularinterventionsaphantomstudy