Accuracy of registration techniques and vascular imaging modalities in fusion imaging for aortic endovascular interventions: a phantom study
BACKGROUND: This study aimed to assess the error of different registration techniques and imaging modalities for fusion imaging of the aorta in a standardized setting using a anthropomorphic body phantom. MATERIALS AND METHODS: A phantom with the 3D printed vasculature of a patient suffering from an...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8200901/ https://www.ncbi.nlm.nih.gov/pubmed/34125287 http://dx.doi.org/10.1186/s42155-021-00234-6 |
_version_ | 1783707697228546048 |
---|---|
author | Sieren, M. M. Schareck, C. Kaschwich, M. Horn, M. Matysiak, F. Stahlberg, E. Wegner, F. Oechtering, T. H. Barkhausen, J. Goltz, J. |
author_facet | Sieren, M. M. Schareck, C. Kaschwich, M. Horn, M. Matysiak, F. Stahlberg, E. Wegner, F. Oechtering, T. H. Barkhausen, J. Goltz, J. |
author_sort | Sieren, M. M. |
collection | PubMed |
description | BACKGROUND: This study aimed to assess the error of different registration techniques and imaging modalities for fusion imaging of the aorta in a standardized setting using a anthropomorphic body phantom. MATERIALS AND METHODS: A phantom with the 3D printed vasculature of a patient suffering from an infrarenal aortic aneurysm was constructed. Pulsatile flow was generated via an external pump. CTA/MRA of the phantom was performed, and a virtual 3D vascular model was computed. Subsequently, fusion imaging was performed employing 3D-3D and 2D-3D registration techniques. Accuracy of the registration was evaluated from 7 right/left anterior oblique c-arm angulations using the agreement of centerlines and landmarks between the phantom vessels and the virtual 3D virtual vascular model. Differences between imaging modalities were assessed in a head-to-head comparison based on centerline deviation. Statistics included the comparison of means ± standard deviations, student’s t-test, Bland-Altman analysis, and intraclass correlation coefficient for intra- and inter-reader analysis. RESULTS: 3D-3D registration was superior to 2D-3D registration, with the highest mean centerline deviation being 1.67 ± 0.24 mm compared to 4.47 ± 0.92 mm. The highest absolute deviation was 3.25 mm for 3D-3D and 6.25 mm for 2D-3D registration. Differences for all angulations between registration techniques reached statistical significance. A decrease in registration accuracy was observed for c-arm angulations beyond 30° right anterior oblique/left anterior oblique. All landmarks (100%) were correctly positioned using 3D-3D registration compared to 81% using 2D-3D registration. Differences in accuracy between CT and MRI were acceptably small. Intra- and inter-reader reliability was excellent. CONCLUSION: In the realm of registration techniques, the 3D-3D method proved more accurate than did the 2D-3D method. Based on our data, the use of 2D-3D registration for interventions with high registration quality requirements (e.g., fenestrated aortic repair procedures) cannot be fully recommended. Regarding imaging modalities, CTA and MRA can be used equivalently. |
format | Online Article Text |
id | pubmed-8200901 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-82009012021-06-28 Accuracy of registration techniques and vascular imaging modalities in fusion imaging for aortic endovascular interventions: a phantom study Sieren, M. M. Schareck, C. Kaschwich, M. Horn, M. Matysiak, F. Stahlberg, E. Wegner, F. Oechtering, T. H. Barkhausen, J. Goltz, J. CVIR Endovasc Original Article BACKGROUND: This study aimed to assess the error of different registration techniques and imaging modalities for fusion imaging of the aorta in a standardized setting using a anthropomorphic body phantom. MATERIALS AND METHODS: A phantom with the 3D printed vasculature of a patient suffering from an infrarenal aortic aneurysm was constructed. Pulsatile flow was generated via an external pump. CTA/MRA of the phantom was performed, and a virtual 3D vascular model was computed. Subsequently, fusion imaging was performed employing 3D-3D and 2D-3D registration techniques. Accuracy of the registration was evaluated from 7 right/left anterior oblique c-arm angulations using the agreement of centerlines and landmarks between the phantom vessels and the virtual 3D virtual vascular model. Differences between imaging modalities were assessed in a head-to-head comparison based on centerline deviation. Statistics included the comparison of means ± standard deviations, student’s t-test, Bland-Altman analysis, and intraclass correlation coefficient for intra- and inter-reader analysis. RESULTS: 3D-3D registration was superior to 2D-3D registration, with the highest mean centerline deviation being 1.67 ± 0.24 mm compared to 4.47 ± 0.92 mm. The highest absolute deviation was 3.25 mm for 3D-3D and 6.25 mm for 2D-3D registration. Differences for all angulations between registration techniques reached statistical significance. A decrease in registration accuracy was observed for c-arm angulations beyond 30° right anterior oblique/left anterior oblique. All landmarks (100%) were correctly positioned using 3D-3D registration compared to 81% using 2D-3D registration. Differences in accuracy between CT and MRI were acceptably small. Intra- and inter-reader reliability was excellent. CONCLUSION: In the realm of registration techniques, the 3D-3D method proved more accurate than did the 2D-3D method. Based on our data, the use of 2D-3D registration for interventions with high registration quality requirements (e.g., fenestrated aortic repair procedures) cannot be fully recommended. Regarding imaging modalities, CTA and MRA can be used equivalently. Springer International Publishing 2021-06-14 /pmc/articles/PMC8200901/ /pubmed/34125287 http://dx.doi.org/10.1186/s42155-021-00234-6 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Original Article Sieren, M. M. Schareck, C. Kaschwich, M. Horn, M. Matysiak, F. Stahlberg, E. Wegner, F. Oechtering, T. H. Barkhausen, J. Goltz, J. Accuracy of registration techniques and vascular imaging modalities in fusion imaging for aortic endovascular interventions: a phantom study |
title | Accuracy of registration techniques and vascular imaging modalities in fusion imaging for aortic endovascular interventions: a phantom study |
title_full | Accuracy of registration techniques and vascular imaging modalities in fusion imaging for aortic endovascular interventions: a phantom study |
title_fullStr | Accuracy of registration techniques and vascular imaging modalities in fusion imaging for aortic endovascular interventions: a phantom study |
title_full_unstemmed | Accuracy of registration techniques and vascular imaging modalities in fusion imaging for aortic endovascular interventions: a phantom study |
title_short | Accuracy of registration techniques and vascular imaging modalities in fusion imaging for aortic endovascular interventions: a phantom study |
title_sort | accuracy of registration techniques and vascular imaging modalities in fusion imaging for aortic endovascular interventions: a phantom study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8200901/ https://www.ncbi.nlm.nih.gov/pubmed/34125287 http://dx.doi.org/10.1186/s42155-021-00234-6 |
work_keys_str_mv | AT sierenmm accuracyofregistrationtechniquesandvascularimagingmodalitiesinfusionimagingforaorticendovascularinterventionsaphantomstudy AT schareckc accuracyofregistrationtechniquesandvascularimagingmodalitiesinfusionimagingforaorticendovascularinterventionsaphantomstudy AT kaschwichm accuracyofregistrationtechniquesandvascularimagingmodalitiesinfusionimagingforaorticendovascularinterventionsaphantomstudy AT hornm accuracyofregistrationtechniquesandvascularimagingmodalitiesinfusionimagingforaorticendovascularinterventionsaphantomstudy AT matysiakf accuracyofregistrationtechniquesandvascularimagingmodalitiesinfusionimagingforaorticendovascularinterventionsaphantomstudy AT stahlberge accuracyofregistrationtechniquesandvascularimagingmodalitiesinfusionimagingforaorticendovascularinterventionsaphantomstudy AT wegnerf accuracyofregistrationtechniquesandvascularimagingmodalitiesinfusionimagingforaorticendovascularinterventionsaphantomstudy AT oechteringth accuracyofregistrationtechniquesandvascularimagingmodalitiesinfusionimagingforaorticendovascularinterventionsaphantomstudy AT barkhausenj accuracyofregistrationtechniquesandvascularimagingmodalitiesinfusionimagingforaorticendovascularinterventionsaphantomstudy AT goltzj accuracyofregistrationtechniquesandvascularimagingmodalitiesinfusionimagingforaorticendovascularinterventionsaphantomstudy |