Factors That Cause Concerns after Cardioverter Defibrillator Implantation

Background and Objectives: The aim of the study was to assess the factors that influence the occurrence of concerns and their intensification after the implantation of a cardioverter defibrillator. Materials and Methods: This was a prospective and observational study including 158 patients. The stud...

Descripción completa

Detalles Bibliográficos
Autores principales: Karczewska, Olimpia, Młynarska, Agnieszka
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8201053/
https://www.ncbi.nlm.nih.gov/pubmed/34198777
http://dx.doi.org/10.3390/ijerph18116095
_version_ 1783707727260811264
author Karczewska, Olimpia
Młynarska, Agnieszka
author_facet Karczewska, Olimpia
Młynarska, Agnieszka
author_sort Karczewska, Olimpia
collection PubMed
description Background and Objectives: The aim of the study was to assess the factors that influence the occurrence of concerns and their intensification after the implantation of a cardioverter defibrillator. Materials and Methods: This was a prospective and observational study including 158 patients. The study was conducted in two stages: stage I before implantable cardioverter defibrillator (ICD) implantation and stage II follow-up visit six months after ICD implantation. Standardized questionnaires were used in both stages. Results: Age and female gender were significantly correlated with the occurrence and intensity of concerns. Patients who had a device implanted for secondary prevention also experienced higher levels of concern. Additionally, a multiple regression model using the stepwise input method was performed. The model was statistically significant and explained 42% of the observed variance in the dependent variable (p = 0.0001, R(2) = 0.4215). The analysis showed that age (p = 0.0036), insomnia (p = 0.0276), anxiety (p = 0.0000) and negative emotions (p = 0.0374) were important predictors of the dependent variable and enabled higher levels of the number of concerns to be predicted. Conclusions: There is a relationship between the severity of the concerns related to an implanted ICD and age, gender, anxiety, negative emotions and insomnia. Indications for ICD implantation may be associated with increased concerns about ICD.
format Online
Article
Text
id pubmed-8201053
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-82010532021-06-15 Factors That Cause Concerns after Cardioverter Defibrillator Implantation Karczewska, Olimpia Młynarska, Agnieszka Int J Environ Res Public Health Article Background and Objectives: The aim of the study was to assess the factors that influence the occurrence of concerns and their intensification after the implantation of a cardioverter defibrillator. Materials and Methods: This was a prospective and observational study including 158 patients. The study was conducted in two stages: stage I before implantable cardioverter defibrillator (ICD) implantation and stage II follow-up visit six months after ICD implantation. Standardized questionnaires were used in both stages. Results: Age and female gender were significantly correlated with the occurrence and intensity of concerns. Patients who had a device implanted for secondary prevention also experienced higher levels of concern. Additionally, a multiple regression model using the stepwise input method was performed. The model was statistically significant and explained 42% of the observed variance in the dependent variable (p = 0.0001, R(2) = 0.4215). The analysis showed that age (p = 0.0036), insomnia (p = 0.0276), anxiety (p = 0.0000) and negative emotions (p = 0.0374) were important predictors of the dependent variable and enabled higher levels of the number of concerns to be predicted. Conclusions: There is a relationship between the severity of the concerns related to an implanted ICD and age, gender, anxiety, negative emotions and insomnia. Indications for ICD implantation may be associated with increased concerns about ICD. MDPI 2021-06-05 /pmc/articles/PMC8201053/ /pubmed/34198777 http://dx.doi.org/10.3390/ijerph18116095 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Karczewska, Olimpia
Młynarska, Agnieszka
Factors That Cause Concerns after Cardioverter Defibrillator Implantation
title Factors That Cause Concerns after Cardioverter Defibrillator Implantation
title_full Factors That Cause Concerns after Cardioverter Defibrillator Implantation
title_fullStr Factors That Cause Concerns after Cardioverter Defibrillator Implantation
title_full_unstemmed Factors That Cause Concerns after Cardioverter Defibrillator Implantation
title_short Factors That Cause Concerns after Cardioverter Defibrillator Implantation
title_sort factors that cause concerns after cardioverter defibrillator implantation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8201053/
https://www.ncbi.nlm.nih.gov/pubmed/34198777
http://dx.doi.org/10.3390/ijerph18116095
work_keys_str_mv AT karczewskaolimpia factorsthatcauseconcernsaftercardioverterdefibrillatorimplantation
AT młynarskaagnieszka factorsthatcauseconcernsaftercardioverterdefibrillatorimplantation