Cargando…

Optimum PZT Patch Size for Corrosion Detection in Reinforced Concrete Using the Electromechanical Impedance Technique

This paper proposes the use of a 1-dimensional (1-D) electromechanical impedance model to extract proper design guidelines when selecting patch-size and frequency range for corrosion detection in reinforced concrete structures using the electromechanical impedance (EMI) technique. The theoretical re...

Descripción completa

Detalles Bibliográficos
Autores principales: Hire, Jaamac Hassan, Hosseini, Seyedsina, Moradi, Farshad
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8201211/
https://www.ncbi.nlm.nih.gov/pubmed/34198764
http://dx.doi.org/10.3390/s21113903
_version_ 1783707764963409920
author Hire, Jaamac Hassan
Hosseini, Seyedsina
Moradi, Farshad
author_facet Hire, Jaamac Hassan
Hosseini, Seyedsina
Moradi, Farshad
author_sort Hire, Jaamac Hassan
collection PubMed
description This paper proposes the use of a 1-dimensional (1-D) electromechanical impedance model to extract proper design guidelines when selecting patch-size and frequency range for corrosion detection in reinforced concrete structures using the electromechanical impedance (EMI) technique. The theoretical results show that the sensitivity mainly lies in the peak frequencies of the impedance spectrum, while outside resonant frequencies the sensitivity levels are low, and are prone to natural variation. If the mechanical impedance ratio between the host structure and patch is too large, the peaks and thereby the sensitivity decreases. This can be counteracted by increasing the patch thickness. Tests were carried out in reinforced concrete structures, where lead zirconate titanate (PZT) patches were attached to the rebars. Patches measuring 10 × 10 mm in length and width, with thicknesses of 0.3, 0.5 and 1.5 mm, were used. The results show that only the 10 × 10 × 1.5 mm patch, was able to generate a clear peak in the 50 kHz to 400 kHz impedance spectrum. Furthermore, a reinforced concrete structure with the 1.5 mm patch attached was induced significant corrosion damages, resulting in cracking of the structure. Due to this, a leftward shift of the main peak, and creation of new peaks in the spectrum was observed.
format Online
Article
Text
id pubmed-8201211
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-82012112021-06-15 Optimum PZT Patch Size for Corrosion Detection in Reinforced Concrete Using the Electromechanical Impedance Technique Hire, Jaamac Hassan Hosseini, Seyedsina Moradi, Farshad Sensors (Basel) Article This paper proposes the use of a 1-dimensional (1-D) electromechanical impedance model to extract proper design guidelines when selecting patch-size and frequency range for corrosion detection in reinforced concrete structures using the electromechanical impedance (EMI) technique. The theoretical results show that the sensitivity mainly lies in the peak frequencies of the impedance spectrum, while outside resonant frequencies the sensitivity levels are low, and are prone to natural variation. If the mechanical impedance ratio between the host structure and patch is too large, the peaks and thereby the sensitivity decreases. This can be counteracted by increasing the patch thickness. Tests were carried out in reinforced concrete structures, where lead zirconate titanate (PZT) patches were attached to the rebars. Patches measuring 10 × 10 mm in length and width, with thicknesses of 0.3, 0.5 and 1.5 mm, were used. The results show that only the 10 × 10 × 1.5 mm patch, was able to generate a clear peak in the 50 kHz to 400 kHz impedance spectrum. Furthermore, a reinforced concrete structure with the 1.5 mm patch attached was induced significant corrosion damages, resulting in cracking of the structure. Due to this, a leftward shift of the main peak, and creation of new peaks in the spectrum was observed. MDPI 2021-06-05 /pmc/articles/PMC8201211/ /pubmed/34198764 http://dx.doi.org/10.3390/s21113903 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Hire, Jaamac Hassan
Hosseini, Seyedsina
Moradi, Farshad
Optimum PZT Patch Size for Corrosion Detection in Reinforced Concrete Using the Electromechanical Impedance Technique
title Optimum PZT Patch Size for Corrosion Detection in Reinforced Concrete Using the Electromechanical Impedance Technique
title_full Optimum PZT Patch Size for Corrosion Detection in Reinforced Concrete Using the Electromechanical Impedance Technique
title_fullStr Optimum PZT Patch Size for Corrosion Detection in Reinforced Concrete Using the Electromechanical Impedance Technique
title_full_unstemmed Optimum PZT Patch Size for Corrosion Detection in Reinforced Concrete Using the Electromechanical Impedance Technique
title_short Optimum PZT Patch Size for Corrosion Detection in Reinforced Concrete Using the Electromechanical Impedance Technique
title_sort optimum pzt patch size for corrosion detection in reinforced concrete using the electromechanical impedance technique
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8201211/
https://www.ncbi.nlm.nih.gov/pubmed/34198764
http://dx.doi.org/10.3390/s21113903
work_keys_str_mv AT hirejaamachassan optimumpztpatchsizeforcorrosiondetectioninreinforcedconcreteusingtheelectromechanicalimpedancetechnique
AT hosseiniseyedsina optimumpztpatchsizeforcorrosiondetectioninreinforcedconcreteusingtheelectromechanicalimpedancetechnique
AT moradifarshad optimumpztpatchsizeforcorrosiondetectioninreinforcedconcreteusingtheelectromechanicalimpedancetechnique