Cargando…

Critical Limb Ischemia in a Young Patient With a Mechanical Aortic Valve Leading to Bilateral Above-Knee Amputation

This case reports a 24-year-old female with prior aortic insufficiency who underwent a mechanical aortic valve replacement with subsequent transient ischemic attacks and documented subtherapeutic international normalized ratio (INR). She presented with pain and bilateral lower extremity pulselessnes...

Descripción completa

Detalles Bibliográficos
Autores principales: Kamath, Shiwani, Ulhaque, Abid, Ali, Rias, Frunzi, Johnathan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8202806/
https://www.ncbi.nlm.nih.gov/pubmed/34150397
http://dx.doi.org/10.7759/cureus.15046
_version_ 1783708037774573568
author Kamath, Shiwani
Ulhaque, Abid
Ali, Rias
Frunzi, Johnathan
author_facet Kamath, Shiwani
Ulhaque, Abid
Ali, Rias
Frunzi, Johnathan
author_sort Kamath, Shiwani
collection PubMed
description This case reports a 24-year-old female with prior aortic insufficiency who underwent a mechanical aortic valve replacement with subsequent transient ischemic attacks and documented subtherapeutic international normalized ratio (INR). She presented with pain and bilateral lower extremity pulselessness. Workup showed a supratherapeutic INR, no thrombus on echocardiogram, and computed tomography angiography demonstrating no flow in the bilateral common femoral arteries. Patient failed repeated thrombectomies and had a bilateral above-knee amputation. The patient was suspected to have acute on chronic emboli from the mechanical aortic valve and further testing did not elucidate contributory causes of her critical limb ischemia. We believe this is the first documented case of bilateral lower extremity ischemia due to mechanical valve complications.
format Online
Article
Text
id pubmed-8202806
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-82028062021-06-17 Critical Limb Ischemia in a Young Patient With a Mechanical Aortic Valve Leading to Bilateral Above-Knee Amputation Kamath, Shiwani Ulhaque, Abid Ali, Rias Frunzi, Johnathan Cureus Cardiac/Thoracic/Vascular Surgery This case reports a 24-year-old female with prior aortic insufficiency who underwent a mechanical aortic valve replacement with subsequent transient ischemic attacks and documented subtherapeutic international normalized ratio (INR). She presented with pain and bilateral lower extremity pulselessness. Workup showed a supratherapeutic INR, no thrombus on echocardiogram, and computed tomography angiography demonstrating no flow in the bilateral common femoral arteries. Patient failed repeated thrombectomies and had a bilateral above-knee amputation. The patient was suspected to have acute on chronic emboli from the mechanical aortic valve and further testing did not elucidate contributory causes of her critical limb ischemia. We believe this is the first documented case of bilateral lower extremity ischemia due to mechanical valve complications. Cureus 2021-05-15 /pmc/articles/PMC8202806/ /pubmed/34150397 http://dx.doi.org/10.7759/cureus.15046 Text en Copyright © 2021, Kamath et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Cardiac/Thoracic/Vascular Surgery
Kamath, Shiwani
Ulhaque, Abid
Ali, Rias
Frunzi, Johnathan
Critical Limb Ischemia in a Young Patient With a Mechanical Aortic Valve Leading to Bilateral Above-Knee Amputation
title Critical Limb Ischemia in a Young Patient With a Mechanical Aortic Valve Leading to Bilateral Above-Knee Amputation
title_full Critical Limb Ischemia in a Young Patient With a Mechanical Aortic Valve Leading to Bilateral Above-Knee Amputation
title_fullStr Critical Limb Ischemia in a Young Patient With a Mechanical Aortic Valve Leading to Bilateral Above-Knee Amputation
title_full_unstemmed Critical Limb Ischemia in a Young Patient With a Mechanical Aortic Valve Leading to Bilateral Above-Knee Amputation
title_short Critical Limb Ischemia in a Young Patient With a Mechanical Aortic Valve Leading to Bilateral Above-Knee Amputation
title_sort critical limb ischemia in a young patient with a mechanical aortic valve leading to bilateral above-knee amputation
topic Cardiac/Thoracic/Vascular Surgery
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8202806/
https://www.ncbi.nlm.nih.gov/pubmed/34150397
http://dx.doi.org/10.7759/cureus.15046
work_keys_str_mv AT kamathshiwani criticallimbischemiainayoungpatientwithamechanicalaorticvalveleadingtobilateralabovekneeamputation
AT ulhaqueabid criticallimbischemiainayoungpatientwithamechanicalaorticvalveleadingtobilateralabovekneeamputation
AT alirias criticallimbischemiainayoungpatientwithamechanicalaorticvalveleadingtobilateralabovekneeamputation
AT frunzijohnathan criticallimbischemiainayoungpatientwithamechanicalaorticvalveleadingtobilateralabovekneeamputation