The effect of measurement area size on the reliability of myocardial iron load measurement in cardiac magnetic resonance imaging examinations of thalassemia patients
BACKGROUND/AIM: The aim of this study was to evaluate the intraobserver and interobserver reliability of cardiac T2* MRI measurements in different region of interest (ROI) sizes. MATERIALS AND METHODS: Cardiac T2* MRIs of 24 thalassemia major patients were evaluated. Two different ROI sizes were use...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Scientific and Technological Research Council of Turkey
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8203176/ https://www.ncbi.nlm.nih.gov/pubmed/33003691 http://dx.doi.org/10.3906/sag-1804-139 |
_version_ | 1783708114912018432 |
---|---|
author | YENİÇERİ, İbrahim Önder AZIK, Fatih Mehmet ELİBOL, Funda Dinç |
author_facet | YENİÇERİ, İbrahim Önder AZIK, Fatih Mehmet ELİBOL, Funda Dinç |
author_sort | YENİÇERİ, İbrahim Önder |
collection | PubMed |
description | BACKGROUND/AIM: The aim of this study was to evaluate the intraobserver and interobserver reliability of cardiac T2* MRI measurements in different region of interest (ROI) sizes. MATERIALS AND METHODS: Cardiac T2* MRIs of 24 thalassemia major patients were evaluated. Two different ROI sizes were used for measurement. In the first measurement, an ROI approximately 5 mm in diameter was used in the interventricular septal myocardium. In the other method, the whole ventricular septal myocardium was used as the measurement. The intraobserver and interobserver variabilities were assessed with the intraclass correlation coefficient (ICC). RESULTS: The measurement of the first observer, the ICC of the small-sized ROI (ssROI), was 0.869, and the measurement for the second observer, the ICC of the ssROI, was 0.659. The ICC of the whole-septal ROI (wsROI) was 0.991 for the first observer and 0.980 for the second observer. Interobserver variability, for the mean measurement, was 0.442 for the ICC of ssROI and 0.883 for the ICC of wsROI. CONCLUSION: For the evaluation of myocardial iron load with T2* MRI we suggest making measurements with ROI, including all of the interventricular septum, as a consequence of high intraobserver and interobserver consistency. |
format | Online Article Text |
id | pubmed-8203176 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | The Scientific and Technological Research Council of Turkey |
record_format | MEDLINE/PubMed |
spelling | pubmed-82031762021-06-24 The effect of measurement area size on the reliability of myocardial iron load measurement in cardiac magnetic resonance imaging examinations of thalassemia patients YENİÇERİ, İbrahim Önder AZIK, Fatih Mehmet ELİBOL, Funda Dinç Turk J Med Sci Article BACKGROUND/AIM: The aim of this study was to evaluate the intraobserver and interobserver reliability of cardiac T2* MRI measurements in different region of interest (ROI) sizes. MATERIALS AND METHODS: Cardiac T2* MRIs of 24 thalassemia major patients were evaluated. Two different ROI sizes were used for measurement. In the first measurement, an ROI approximately 5 mm in diameter was used in the interventricular septal myocardium. In the other method, the whole ventricular septal myocardium was used as the measurement. The intraobserver and interobserver variabilities were assessed with the intraclass correlation coefficient (ICC). RESULTS: The measurement of the first observer, the ICC of the small-sized ROI (ssROI), was 0.869, and the measurement for the second observer, the ICC of the ssROI, was 0.659. The ICC of the whole-septal ROI (wsROI) was 0.991 for the first observer and 0.980 for the second observer. Interobserver variability, for the mean measurement, was 0.442 for the ICC of ssROI and 0.883 for the ICC of wsROI. CONCLUSION: For the evaluation of myocardial iron load with T2* MRI we suggest making measurements with ROI, including all of the interventricular septum, as a consequence of high intraobserver and interobserver consistency. The Scientific and Technological Research Council of Turkey 2021-04-30 /pmc/articles/PMC8203176/ /pubmed/33003691 http://dx.doi.org/10.3906/sag-1804-139 Text en Copyright © 2021 The Author(s) https://creativecommons.org/licenses/by/4.0/This article is distributed under the terms of the Creative Commons Attribution License ( http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ), which permits unrestricted use and redistribution provided that the original author and source are credited. |
spellingShingle | Article YENİÇERİ, İbrahim Önder AZIK, Fatih Mehmet ELİBOL, Funda Dinç The effect of measurement area size on the reliability of myocardial iron load measurement in cardiac magnetic resonance imaging examinations of thalassemia patients |
title | The effect of measurement area size on the reliability of myocardial iron load measurement in cardiac magnetic resonance imaging examinations of thalassemia patients |
title_full | The effect of measurement area size on the reliability of myocardial iron load measurement in cardiac magnetic resonance imaging examinations of thalassemia patients |
title_fullStr | The effect of measurement area size on the reliability of myocardial iron load measurement in cardiac magnetic resonance imaging examinations of thalassemia patients |
title_full_unstemmed | The effect of measurement area size on the reliability of myocardial iron load measurement in cardiac magnetic resonance imaging examinations of thalassemia patients |
title_short | The effect of measurement area size on the reliability of myocardial iron load measurement in cardiac magnetic resonance imaging examinations of thalassemia patients |
title_sort | effect of measurement area size on the reliability of myocardial iron load measurement in cardiac magnetic resonance imaging examinations of thalassemia patients |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8203176/ https://www.ncbi.nlm.nih.gov/pubmed/33003691 http://dx.doi.org/10.3906/sag-1804-139 |
work_keys_str_mv | AT yeniceriibrahimonder theeffectofmeasurementareasizeonthereliabilityofmyocardialironloadmeasurementincardiacmagneticresonanceimagingexaminationsofthalassemiapatients AT azikfatihmehmet theeffectofmeasurementareasizeonthereliabilityofmyocardialironloadmeasurementincardiacmagneticresonanceimagingexaminationsofthalassemiapatients AT elibolfundadinc theeffectofmeasurementareasizeonthereliabilityofmyocardialironloadmeasurementincardiacmagneticresonanceimagingexaminationsofthalassemiapatients AT yeniceriibrahimonder effectofmeasurementareasizeonthereliabilityofmyocardialironloadmeasurementincardiacmagneticresonanceimagingexaminationsofthalassemiapatients AT azikfatihmehmet effectofmeasurementareasizeonthereliabilityofmyocardialironloadmeasurementincardiacmagneticresonanceimagingexaminationsofthalassemiapatients AT elibolfundadinc effectofmeasurementareasizeonthereliabilityofmyocardialironloadmeasurementincardiacmagneticresonanceimagingexaminationsofthalassemiapatients |