Cargando…

The effect of measurement area size on the reliability of myocardial iron load measurement in cardiac magnetic resonance imaging examinations of thalassemia patients

BACKGROUND/AIM: The aim of this study was to evaluate the intraobserver and interobserver reliability of cardiac T2* MRI measurements in different region of interest (ROI) sizes. MATERIALS AND METHODS: Cardiac T2* MRIs of 24 thalassemia major patients were evaluated. Two different ROI sizes were use...

Descripción completa

Detalles Bibliográficos
Autores principales: YENİÇERİ, İbrahim Önder, AZIK, Fatih Mehmet, ELİBOL, Funda Dinç
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Scientific and Technological Research Council of Turkey 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8203176/
https://www.ncbi.nlm.nih.gov/pubmed/33003691
http://dx.doi.org/10.3906/sag-1804-139
_version_ 1783708114912018432
author YENİÇERİ, İbrahim Önder
AZIK, Fatih Mehmet
ELİBOL, Funda Dinç
author_facet YENİÇERİ, İbrahim Önder
AZIK, Fatih Mehmet
ELİBOL, Funda Dinç
author_sort YENİÇERİ, İbrahim Önder
collection PubMed
description BACKGROUND/AIM: The aim of this study was to evaluate the intraobserver and interobserver reliability of cardiac T2* MRI measurements in different region of interest (ROI) sizes. MATERIALS AND METHODS: Cardiac T2* MRIs of 24 thalassemia major patients were evaluated. Two different ROI sizes were used for measurement. In the first measurement, an ROI approximately 5 mm in diameter was used in the interventricular septal myocardium. In the other method, the whole ventricular septal myocardium was used as the measurement. The intraobserver and interobserver variabilities were assessed with the intraclass correlation coefficient (ICC). RESULTS: The measurement of the first observer, the ICC of the small-sized ROI (ssROI), was 0.869, and the measurement for the second observer, the ICC of the ssROI, was 0.659. The ICC of the whole-septal ROI (wsROI) was 0.991 for the first observer and 0.980 for the second observer. Interobserver variability, for the mean measurement, was 0.442 for the ICC of ssROI and 0.883 for the ICC of wsROI. CONCLUSION: For the evaluation of myocardial iron load with T2* MRI we suggest making measurements with ROI, including all of the interventricular septum, as a consequence of high intraobserver and interobserver consistency.
format Online
Article
Text
id pubmed-8203176
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher The Scientific and Technological Research Council of Turkey
record_format MEDLINE/PubMed
spelling pubmed-82031762021-06-24 The effect of measurement area size on the reliability of myocardial iron load measurement in cardiac magnetic resonance imaging examinations of thalassemia patients YENİÇERİ, İbrahim Önder AZIK, Fatih Mehmet ELİBOL, Funda Dinç Turk J Med Sci Article BACKGROUND/AIM: The aim of this study was to evaluate the intraobserver and interobserver reliability of cardiac T2* MRI measurements in different region of interest (ROI) sizes. MATERIALS AND METHODS: Cardiac T2* MRIs of 24 thalassemia major patients were evaluated. Two different ROI sizes were used for measurement. In the first measurement, an ROI approximately 5 mm in diameter was used in the interventricular septal myocardium. In the other method, the whole ventricular septal myocardium was used as the measurement. The intraobserver and interobserver variabilities were assessed with the intraclass correlation coefficient (ICC). RESULTS: The measurement of the first observer, the ICC of the small-sized ROI (ssROI), was 0.869, and the measurement for the second observer, the ICC of the ssROI, was 0.659. The ICC of the whole-septal ROI (wsROI) was 0.991 for the first observer and 0.980 for the second observer. Interobserver variability, for the mean measurement, was 0.442 for the ICC of ssROI and 0.883 for the ICC of wsROI. CONCLUSION: For the evaluation of myocardial iron load with T2* MRI we suggest making measurements with ROI, including all of the interventricular septum, as a consequence of high intraobserver and interobserver consistency. The Scientific and Technological Research Council of Turkey 2021-04-30 /pmc/articles/PMC8203176/ /pubmed/33003691 http://dx.doi.org/10.3906/sag-1804-139 Text en Copyright © 2021 The Author(s) https://creativecommons.org/licenses/by/4.0/This article is distributed under the terms of the Creative Commons Attribution License ( http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ), which permits unrestricted use and redistribution provided that the original author and source are credited.
spellingShingle Article
YENİÇERİ, İbrahim Önder
AZIK, Fatih Mehmet
ELİBOL, Funda Dinç
The effect of measurement area size on the reliability of myocardial iron load measurement in cardiac magnetic resonance imaging examinations of thalassemia patients
title The effect of measurement area size on the reliability of myocardial iron load measurement in cardiac magnetic resonance imaging examinations of thalassemia patients
title_full The effect of measurement area size on the reliability of myocardial iron load measurement in cardiac magnetic resonance imaging examinations of thalassemia patients
title_fullStr The effect of measurement area size on the reliability of myocardial iron load measurement in cardiac magnetic resonance imaging examinations of thalassemia patients
title_full_unstemmed The effect of measurement area size on the reliability of myocardial iron load measurement in cardiac magnetic resonance imaging examinations of thalassemia patients
title_short The effect of measurement area size on the reliability of myocardial iron load measurement in cardiac magnetic resonance imaging examinations of thalassemia patients
title_sort effect of measurement area size on the reliability of myocardial iron load measurement in cardiac magnetic resonance imaging examinations of thalassemia patients
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8203176/
https://www.ncbi.nlm.nih.gov/pubmed/33003691
http://dx.doi.org/10.3906/sag-1804-139
work_keys_str_mv AT yeniceriibrahimonder theeffectofmeasurementareasizeonthereliabilityofmyocardialironloadmeasurementincardiacmagneticresonanceimagingexaminationsofthalassemiapatients
AT azikfatihmehmet theeffectofmeasurementareasizeonthereliabilityofmyocardialironloadmeasurementincardiacmagneticresonanceimagingexaminationsofthalassemiapatients
AT elibolfundadinc theeffectofmeasurementareasizeonthereliabilityofmyocardialironloadmeasurementincardiacmagneticresonanceimagingexaminationsofthalassemiapatients
AT yeniceriibrahimonder effectofmeasurementareasizeonthereliabilityofmyocardialironloadmeasurementincardiacmagneticresonanceimagingexaminationsofthalassemiapatients
AT azikfatihmehmet effectofmeasurementareasizeonthereliabilityofmyocardialironloadmeasurementincardiacmagneticresonanceimagingexaminationsofthalassemiapatients
AT elibolfundadinc effectofmeasurementareasizeonthereliabilityofmyocardialironloadmeasurementincardiacmagneticresonanceimagingexaminationsofthalassemiapatients