Cargando…

Comparative safety of percutaneous ventricular assist device and intra-aortic balloon pump in acute myocardial infarction-induced cardiogenic shock

BACKGROUND: The relative safety of percutaneous left ventricular assist device (pVAD) and intra-aortic balloon pump (IABP) in patients with cardiogenic shock after acute myocardial infarction remain unknown. METHODS: Multiple databases were searched to identify articles comparing pVAD and IABP. An u...

Descripción completa

Detalles Bibliográficos
Autores principales: Ullah, Waqas, Zghouzi, Mohamed, Mukhtar, Maryam, Banisad, Ali, Alhatemi, Gaith, Sattar, Yasar, Zahid, Salman, Moussa Pacha, Homam, Gardi, Delair, Alraies, M Chadi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8204163/
https://www.ncbi.nlm.nih.gov/pubmed/34127531
http://dx.doi.org/10.1136/openhrt-2021-001662
Descripción
Sumario:BACKGROUND: The relative safety of percutaneous left ventricular assist device (pVAD) and intra-aortic balloon pump (IABP) in patients with cardiogenic shock after acute myocardial infarction remain unknown. METHODS: Multiple databases were searched to identify articles comparing pVAD and IABP. An unadjusted OR was used to calculate hard clinical outcomes and mortality differences on a random effect model. RESULTS: Seven studies comprising 26 726 patients (1110 in the pVAD group and 25 616 in the IABP group) were included. The odds of all-cause mortality (OR 0.57, 95% CI 0.47 to 0.68, p=<0.00001) and need for revascularisation (OR 0.16, 95% CI, 0.07 to 0.38, p=<0.0001) were significantly reduced in patients receiving pVAD compared with IABP. The odds of stroke (OR 1.12, 95% CI 0.14 to 9.17, p=0.91), acute limb ischaemia (OR=2.48, 95% CI 0.39 to 15.66, p=0.33) and major bleeding (OR 0.36, 95% CI 0.01 to 25.39, p=0.64) were not significantly different between the two groups. A sensitivity analysis based on the exclusion of the study with the largest weight showed no difference in the mortality difference between the two mechanical circulatory support devices. CONCLUSIONS: In patients with acute myocardial infarction complicated by cardiogenic shock, there is no significant difference in the adjusted risk of all-cause mortality, major bleeding, stroke and limb ischaemia between the devices. Randomised trials are warranted to investigate further the safety and efficacy of these devices in patients with cardiogenic shock.