Cargando…
Handheld plasmonic biosensor for virus detection in field-settings
After World Health Organization (WHO) announced COVID-19 outbreak a pandemic, we all again realized the importance of developing rapid diagnostic kits. In this article, we introduced a lightweight and field-portable biosensor employing a plasmonic chip based on nanohole arrays integrated to a lensfr...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier B.V.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8206576/ https://www.ncbi.nlm.nih.gov/pubmed/34149185 http://dx.doi.org/10.1016/j.snb.2021.130301 |
_version_ | 1783708657118085120 |
---|---|
author | Cetin, Arif E. Kocer, Zeynep A. Topkaya, Seda Nur Yazici, Ziya Ata |
author_facet | Cetin, Arif E. Kocer, Zeynep A. Topkaya, Seda Nur Yazici, Ziya Ata |
author_sort | Cetin, Arif E. |
collection | PubMed |
description | After World Health Organization (WHO) announced COVID-19 outbreak a pandemic, we all again realized the importance of developing rapid diagnostic kits. In this article, we introduced a lightweight and field-portable biosensor employing a plasmonic chip based on nanohole arrays integrated to a lensfree-imaging framework for label-free detection of viruses in field-settings. The platform utilizes a CMOS (complementary metal–oxide–semiconductor) camera with high quantum efficiency in the spectral window of interest to monitor diffraction field patterns of nanohole arrays under the uniform illumination of an LED (light-emitting diode) source which is spectrally tuned to the plasmonic mode supported by the nanohole arrays. As an example for the applicability of our biosensor for virus detection, we could successfully demonstrate the label-free detection of H1N1 viruses, e.g., swine flu, with medically relevant concentrations. We also developed a low-cost and easy-to-use sample preparation kit to prepare the surface of the plasmonic chip for analyte binding, e.g., virus-antibody binding. In order to reveal a complete biosensor technology, we also developed a user friendly Python™ – based graphical user interface (GUI) that allows direct access to biosensor hardware, taking and processing diffraction field images, and provides virus information to the end-user. Employing highly sensitive nanohole arrays and lensfree-imaging framework, our platform could yield an LOD as low as 10(3) TCID(50)/mL. Providing accurate and rapid sensing information in a handheld platform, weighing only 70 g and 12 cm tall, without the need for bulky and expensive instrumentation, our biosensor could be a very strong candidate for diagnostic applications in resource-poor settings. As our detection scheme is based on the use of antibodies, it could quickly adapt to the detection of different viral diseases, e.g., COVID-19 or influenza, by simply coating the plasmonic chip surface with an antibody possessing affinity to the virus type of interest. Possessing this ability, our biosensor could be swiftly deployed to the field in need for rapid diagnosis, which may be an important asset to prevent the spread of diseases before turning into a pandemic by isolating patients from the population. |
format | Online Article Text |
id | pubmed-8206576 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Elsevier B.V. |
record_format | MEDLINE/PubMed |
spelling | pubmed-82065762021-06-16 Handheld plasmonic biosensor for virus detection in field-settings Cetin, Arif E. Kocer, Zeynep A. Topkaya, Seda Nur Yazici, Ziya Ata Sens Actuators B Chem Article After World Health Organization (WHO) announced COVID-19 outbreak a pandemic, we all again realized the importance of developing rapid diagnostic kits. In this article, we introduced a lightweight and field-portable biosensor employing a plasmonic chip based on nanohole arrays integrated to a lensfree-imaging framework for label-free detection of viruses in field-settings. The platform utilizes a CMOS (complementary metal–oxide–semiconductor) camera with high quantum efficiency in the spectral window of interest to monitor diffraction field patterns of nanohole arrays under the uniform illumination of an LED (light-emitting diode) source which is spectrally tuned to the plasmonic mode supported by the nanohole arrays. As an example for the applicability of our biosensor for virus detection, we could successfully demonstrate the label-free detection of H1N1 viruses, e.g., swine flu, with medically relevant concentrations. We also developed a low-cost and easy-to-use sample preparation kit to prepare the surface of the plasmonic chip for analyte binding, e.g., virus-antibody binding. In order to reveal a complete biosensor technology, we also developed a user friendly Python™ – based graphical user interface (GUI) that allows direct access to biosensor hardware, taking and processing diffraction field images, and provides virus information to the end-user. Employing highly sensitive nanohole arrays and lensfree-imaging framework, our platform could yield an LOD as low as 10(3) TCID(50)/mL. Providing accurate and rapid sensing information in a handheld platform, weighing only 70 g and 12 cm tall, without the need for bulky and expensive instrumentation, our biosensor could be a very strong candidate for diagnostic applications in resource-poor settings. As our detection scheme is based on the use of antibodies, it could quickly adapt to the detection of different viral diseases, e.g., COVID-19 or influenza, by simply coating the plasmonic chip surface with an antibody possessing affinity to the virus type of interest. Possessing this ability, our biosensor could be swiftly deployed to the field in need for rapid diagnosis, which may be an important asset to prevent the spread of diseases before turning into a pandemic by isolating patients from the population. Elsevier B.V. 2021-10-01 2021-06-16 /pmc/articles/PMC8206576/ /pubmed/34149185 http://dx.doi.org/10.1016/j.snb.2021.130301 Text en © 2021 Elsevier B.V. All rights reserved. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active. |
spellingShingle | Article Cetin, Arif E. Kocer, Zeynep A. Topkaya, Seda Nur Yazici, Ziya Ata Handheld plasmonic biosensor for virus detection in field-settings |
title | Handheld plasmonic biosensor for virus detection in field-settings |
title_full | Handheld plasmonic biosensor for virus detection in field-settings |
title_fullStr | Handheld plasmonic biosensor for virus detection in field-settings |
title_full_unstemmed | Handheld plasmonic biosensor for virus detection in field-settings |
title_short | Handheld plasmonic biosensor for virus detection in field-settings |
title_sort | handheld plasmonic biosensor for virus detection in field-settings |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8206576/ https://www.ncbi.nlm.nih.gov/pubmed/34149185 http://dx.doi.org/10.1016/j.snb.2021.130301 |
work_keys_str_mv | AT cetinarife handheldplasmonicbiosensorforvirusdetectioninfieldsettings AT kocerzeynepa handheldplasmonicbiosensorforvirusdetectioninfieldsettings AT topkayasedanur handheldplasmonicbiosensorforvirusdetectioninfieldsettings AT yaziciziyaata handheldplasmonicbiosensorforvirusdetectioninfieldsettings |