Cargando…

Individualized left anterior oblique projection based on pigtail catheter visualization facilitates leadless pacemaker implantation

BACKGROUND: Pacemaker positioning on the right ventricular (RV) septum during implantation is conventionally conducted utilizing two fixed fluoroscopy angles, a 45° left anterior oblique (LAO) and 35° right anterior oblique projection. However, placement location can be suboptimal, especially for le...

Descripción completa

Detalles Bibliográficos
Autores principales: Yamao, Kazuya, Hachiya, Hitoshi, Kusa, Shigeki, Miwa, Naoyuki, Sato, Yoshikazu, Hara, Satoshi, Ohya, Hiroaki, Iesaka, Yoshito, Sasano, Tetsuo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8207349/
https://www.ncbi.nlm.nih.gov/pubmed/34141021
http://dx.doi.org/10.1002/joa3.12540
Descripción
Sumario:BACKGROUND: Pacemaker positioning on the right ventricular (RV) septum during implantation is conventionally conducted utilizing two fixed fluoroscopy angles, a 45° left anterior oblique (LAO) and 35° right anterior oblique projection. However, placement location can be suboptimal, especially for leadless pacemakers (LPMs). OBJECTIVE: To evaluate the safety and ease of LPM implantation using individualized LAO projection. METHODS: Consecutive patients undergoing LPM implantation were prospectively included. The angle of the RV septum was recorded for each patient by studying the angle at which an RV pigtail catheter (RV‐PC) could be seen edge on. This was then used as the preferred LAO projection angle for that patient. We evaluated the success rate and safety of this method. We also compared the RV septum angle as measured by this method versus that measured by chest CT. RESULTS: Of the 31 patients (mean age 80.6 ± 7.0 years, 15 females), LPM implantation was successful in 30. The pacemaker was implanted on the RV septum in 29 and on the free wall in one. LPM implantation was abandoned for anatomical reasons in one. Complications were limited to a groin arteriovenous fistula and one deep vein thrombosis. The angle of RV septum as measured by pigtail catheter and chest CT was not significantly different (CT: 54.8 ± 6.0°, RV pigtail catheter: 52.9 ± 6.1°, P = .07). CONCLUSIONS: Using an RV‐PC to determine the preferred angle of LAO projection facilitates differentiation between the RV septum and free wall, which in turn facilitates optimal LPM placement.