Cargando…

Effect of Sequential Compression Device on Hemodynamic Changes After Spinal Anesthesia for Caesarean Section: A Randomized Controlled Trial

BACKGROUND: The benefit of sequential compression device (SCD) for the prevention of hypotension after spinal anesthesia in cesarean sections has not been determined. OBJECTIVES: In this study, an attempt was made to determine whether SCD can prevent hemodynamic changes following spinal anesthesia f...

Descripción completa

Detalles Bibliográficos
Autores principales: Javaherforooshzadeh, Fatemeh, Pipelzadeh, Mohammad Reza, Akhondzadeh, Reza, Adarvishi, Sara, Alghozat, Mostafa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Kowsar 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8207840/
https://www.ncbi.nlm.nih.gov/pubmed/34150562
http://dx.doi.org/10.5812/aapm.104705
_version_ 1783708850042437632
author Javaherforooshzadeh, Fatemeh
Pipelzadeh, Mohammad Reza
Akhondzadeh, Reza
Adarvishi, Sara
Alghozat, Mostafa
author_facet Javaherforooshzadeh, Fatemeh
Pipelzadeh, Mohammad Reza
Akhondzadeh, Reza
Adarvishi, Sara
Alghozat, Mostafa
author_sort Javaherforooshzadeh, Fatemeh
collection PubMed
description BACKGROUND: The benefit of sequential compression device (SCD) for the prevention of hypotension after spinal anesthesia in cesarean sections has not been determined. OBJECTIVES: In this study, an attempt was made to determine whether SCD can prevent hemodynamic changes following spinal anesthesia for cesarean sections. METHODS: In a prospective clinical trial, 76 parturient women undergoing elective cesarean sections under spinal anesthesia were randomly divided into SCD or control groups. The maternal hemodynamic changes within 75 min after spinal anesthesia, nausea, vomiting, and neonatal Apgar score at 1 and 5 min were compared between the groups. RESULTS: There were no significant differences between the groups in the patients’ characteristics, maximum sensory block, skin incision to delivery time, spinal anesthesia to delivery time (min), and the total duration of surgery. Concerning heart rate changes, RM ANOVA showed a significant difference in the effect of time, groups, and the interaction of the two factors (P < 0.0001, P < 0.0001, and P < 0.0001, respectively). Tukey post hoc test showed that 3 min after spinal anesthesia, diastolic blood pressure was significantly higher in the SCD group than in the control group (P < 0.05). The SCD group had meaningfully lower rates of nausea (P = 0.005) and vomiting (P = 0.001) than the control group. The SCD group also demonstrated a significantly lower mean ephedrine dosage per patient (4.1 mg against 17.1 mg, P = 0.001). However, no significant difference was observed between the groups in terms of neonatal Apgar scores at 1 and 5 minutes. CONCLUSIONS: This study showed that SCD could reduce extensive changes in diastolic blood pressure as an important hemodynamic parameter and the incidence of nausea and vomiting. Thus, SCD can be used in spinal anesthesia care practices for elective cesarean sections.
format Online
Article
Text
id pubmed-8207840
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Kowsar
record_format MEDLINE/PubMed
spelling pubmed-82078402021-06-18 Effect of Sequential Compression Device on Hemodynamic Changes After Spinal Anesthesia for Caesarean Section: A Randomized Controlled Trial Javaherforooshzadeh, Fatemeh Pipelzadeh, Mohammad Reza Akhondzadeh, Reza Adarvishi, Sara Alghozat, Mostafa Anesth Pain Med Research Article BACKGROUND: The benefit of sequential compression device (SCD) for the prevention of hypotension after spinal anesthesia in cesarean sections has not been determined. OBJECTIVES: In this study, an attempt was made to determine whether SCD can prevent hemodynamic changes following spinal anesthesia for cesarean sections. METHODS: In a prospective clinical trial, 76 parturient women undergoing elective cesarean sections under spinal anesthesia were randomly divided into SCD or control groups. The maternal hemodynamic changes within 75 min after spinal anesthesia, nausea, vomiting, and neonatal Apgar score at 1 and 5 min were compared between the groups. RESULTS: There were no significant differences between the groups in the patients’ characteristics, maximum sensory block, skin incision to delivery time, spinal anesthesia to delivery time (min), and the total duration of surgery. Concerning heart rate changes, RM ANOVA showed a significant difference in the effect of time, groups, and the interaction of the two factors (P < 0.0001, P < 0.0001, and P < 0.0001, respectively). Tukey post hoc test showed that 3 min after spinal anesthesia, diastolic blood pressure was significantly higher in the SCD group than in the control group (P < 0.05). The SCD group had meaningfully lower rates of nausea (P = 0.005) and vomiting (P = 0.001) than the control group. The SCD group also demonstrated a significantly lower mean ephedrine dosage per patient (4.1 mg against 17.1 mg, P = 0.001). However, no significant difference was observed between the groups in terms of neonatal Apgar scores at 1 and 5 minutes. CONCLUSIONS: This study showed that SCD could reduce extensive changes in diastolic blood pressure as an important hemodynamic parameter and the incidence of nausea and vomiting. Thus, SCD can be used in spinal anesthesia care practices for elective cesarean sections. Kowsar 2020-08-25 /pmc/articles/PMC8207840/ /pubmed/34150562 http://dx.doi.org/10.5812/aapm.104705 Text en Copyright © 2020, Author(s) https://creativecommons.org/licenses/by-nc/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits copy and redistribute the material just in noncommercial usages, provided the original work is properly cited.
spellingShingle Research Article
Javaherforooshzadeh, Fatemeh
Pipelzadeh, Mohammad Reza
Akhondzadeh, Reza
Adarvishi, Sara
Alghozat, Mostafa
Effect of Sequential Compression Device on Hemodynamic Changes After Spinal Anesthesia for Caesarean Section: A Randomized Controlled Trial
title Effect of Sequential Compression Device on Hemodynamic Changes After Spinal Anesthesia for Caesarean Section: A Randomized Controlled Trial
title_full Effect of Sequential Compression Device on Hemodynamic Changes After Spinal Anesthesia for Caesarean Section: A Randomized Controlled Trial
title_fullStr Effect of Sequential Compression Device on Hemodynamic Changes After Spinal Anesthesia for Caesarean Section: A Randomized Controlled Trial
title_full_unstemmed Effect of Sequential Compression Device on Hemodynamic Changes After Spinal Anesthesia for Caesarean Section: A Randomized Controlled Trial
title_short Effect of Sequential Compression Device on Hemodynamic Changes After Spinal Anesthesia for Caesarean Section: A Randomized Controlled Trial
title_sort effect of sequential compression device on hemodynamic changes after spinal anesthesia for caesarean section: a randomized controlled trial
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8207840/
https://www.ncbi.nlm.nih.gov/pubmed/34150562
http://dx.doi.org/10.5812/aapm.104705
work_keys_str_mv AT javaherforooshzadehfatemeh effectofsequentialcompressiondeviceonhemodynamicchangesafterspinalanesthesiaforcaesareansectionarandomizedcontrolledtrial
AT pipelzadehmohammadreza effectofsequentialcompressiondeviceonhemodynamicchangesafterspinalanesthesiaforcaesareansectionarandomizedcontrolledtrial
AT akhondzadehreza effectofsequentialcompressiondeviceonhemodynamicchangesafterspinalanesthesiaforcaesareansectionarandomizedcontrolledtrial
AT adarvishisara effectofsequentialcompressiondeviceonhemodynamicchangesafterspinalanesthesiaforcaesareansectionarandomizedcontrolledtrial
AT alghozatmostafa effectofsequentialcompressiondeviceonhemodynamicchangesafterspinalanesthesiaforcaesareansectionarandomizedcontrolledtrial