The use of minimal fluoroscopy for cardiac electrophysiology procedures: A meta‐analysis and review of the literature

BACKGROUND: Conventional catheter ablation involves prolonged exposure to ionizing radiation, potentially leading to detrimental health effects. Minimal fluoroscopy (MF) represents a safer alternative, which should be explored. Data on the safety and efficacy of this technique are limited. HYPOTHESI...

Descripción completa

Detalles Bibliográficos
Autores principales: Chiang, Lorraine Lok Wing, Li, Christien, Hong, Kathryn L, Hui, Winsy Sin, Beh, Sze Yi, Gong, Mengqi, Liu, Tong, Li, Guangping, Xia, Yunlong, Ho, Jeffery, Roever, Leonardo, Duong, Sophia, Huang, Grace, Tse, Gary, Baranchuk, Adrian, Glover, Benedict M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wiley Periodicals, Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8207968/
https://www.ncbi.nlm.nih.gov/pubmed/33998690
http://dx.doi.org/10.1002/clc.23609
_version_ 1783708863261835264
author Chiang, Lorraine Lok Wing
Li, Christien
Hong, Kathryn L
Hui, Winsy Sin
Beh, Sze Yi
Gong, Mengqi
Liu, Tong
Li, Guangping
Xia, Yunlong
Ho, Jeffery
Roever, Leonardo
Duong, Sophia
Huang, Grace
Tse, Gary
Baranchuk, Adrian
Glover, Benedict M.
author_facet Chiang, Lorraine Lok Wing
Li, Christien
Hong, Kathryn L
Hui, Winsy Sin
Beh, Sze Yi
Gong, Mengqi
Liu, Tong
Li, Guangping
Xia, Yunlong
Ho, Jeffery
Roever, Leonardo
Duong, Sophia
Huang, Grace
Tse, Gary
Baranchuk, Adrian
Glover, Benedict M.
author_sort Chiang, Lorraine Lok Wing
collection PubMed
description BACKGROUND: Conventional catheter ablation involves prolonged exposure to ionizing radiation, potentially leading to detrimental health effects. Minimal fluoroscopy (MF) represents a safer alternative, which should be explored. Data on the safety and efficacy of this technique are limited. HYPOTHESIS: Our hypothesis is that MF is of equal efficacy and safety to conventional catheter ablation with the use of fluoroscopy by performing a meta‐analysis of both randomized controlled trials (RCTs) and real‐world registry studies. METHODS: Pubmed and Embase were searched from their inception to July 2020 for RCTs, cohort and observational studies that assessed the outcomes of catheter ablation using a MF technique versus the conventional approach. RESULTS: Fifteen studies involving 3795 patients were included in this meta‐analysis. There was a significant reduction in fluoroscopy and procedural time with no difference in acute success (odds ratio [OR]:0.74, 95% CI: 0.50–1.10, p = .14), long‐term success (OR:0.92, 95% CI: 0.65–1.31, p = .38), arrhythmia recurrence (OR:1.24, 95% CI: 0.75–2.06, p = .97) or rate of complications. (OR:0.83, 95% CI: 0.46–1.48, p = .65). Additionally sub‐group analysis for those undergoing catheter ablation for atrial fibrillation (AF) did not demonstrate a difference in success or complication rates (OR:0.86, 95% CI: 0.30–2.42, p = .77). Multivariate meta‐regression did not identify the presence of moderator variables. CONCLUSION: This updated meta‐analysis demonstrated an overall reduction in procedural and fluoroscopy time for those undergoing a minimal fluoroscopic approach. There was no significant difference in either acute or chronic success rates or complications between a MF approach and conventional approach for the management of all arrhythmias including those undergoing catheter ablation for AF.
format Online
Article
Text
id pubmed-8207968
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Wiley Periodicals, Inc.
record_format MEDLINE/PubMed
spelling pubmed-82079682021-06-25 The use of minimal fluoroscopy for cardiac electrophysiology procedures: A meta‐analysis and review of the literature Chiang, Lorraine Lok Wing Li, Christien Hong, Kathryn L Hui, Winsy Sin Beh, Sze Yi Gong, Mengqi Liu, Tong Li, Guangping Xia, Yunlong Ho, Jeffery Roever, Leonardo Duong, Sophia Huang, Grace Tse, Gary Baranchuk, Adrian Glover, Benedict M. Clin Cardiol Clinical Investigations BACKGROUND: Conventional catheter ablation involves prolonged exposure to ionizing radiation, potentially leading to detrimental health effects. Minimal fluoroscopy (MF) represents a safer alternative, which should be explored. Data on the safety and efficacy of this technique are limited. HYPOTHESIS: Our hypothesis is that MF is of equal efficacy and safety to conventional catheter ablation with the use of fluoroscopy by performing a meta‐analysis of both randomized controlled trials (RCTs) and real‐world registry studies. METHODS: Pubmed and Embase were searched from their inception to July 2020 for RCTs, cohort and observational studies that assessed the outcomes of catheter ablation using a MF technique versus the conventional approach. RESULTS: Fifteen studies involving 3795 patients were included in this meta‐analysis. There was a significant reduction in fluoroscopy and procedural time with no difference in acute success (odds ratio [OR]:0.74, 95% CI: 0.50–1.10, p = .14), long‐term success (OR:0.92, 95% CI: 0.65–1.31, p = .38), arrhythmia recurrence (OR:1.24, 95% CI: 0.75–2.06, p = .97) or rate of complications. (OR:0.83, 95% CI: 0.46–1.48, p = .65). Additionally sub‐group analysis for those undergoing catheter ablation for atrial fibrillation (AF) did not demonstrate a difference in success or complication rates (OR:0.86, 95% CI: 0.30–2.42, p = .77). Multivariate meta‐regression did not identify the presence of moderator variables. CONCLUSION: This updated meta‐analysis demonstrated an overall reduction in procedural and fluoroscopy time for those undergoing a minimal fluoroscopic approach. There was no significant difference in either acute or chronic success rates or complications between a MF approach and conventional approach for the management of all arrhythmias including those undergoing catheter ablation for AF. Wiley Periodicals, Inc. 2021-05-17 /pmc/articles/PMC8207968/ /pubmed/33998690 http://dx.doi.org/10.1002/clc.23609 Text en © 2021 The Authors. Clinical Cardiology published by Wiley Periodicals LLC. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Investigations
Chiang, Lorraine Lok Wing
Li, Christien
Hong, Kathryn L
Hui, Winsy Sin
Beh, Sze Yi
Gong, Mengqi
Liu, Tong
Li, Guangping
Xia, Yunlong
Ho, Jeffery
Roever, Leonardo
Duong, Sophia
Huang, Grace
Tse, Gary
Baranchuk, Adrian
Glover, Benedict M.
The use of minimal fluoroscopy for cardiac electrophysiology procedures: A meta‐analysis and review of the literature
title The use of minimal fluoroscopy for cardiac electrophysiology procedures: A meta‐analysis and review of the literature
title_full The use of minimal fluoroscopy for cardiac electrophysiology procedures: A meta‐analysis and review of the literature
title_fullStr The use of minimal fluoroscopy for cardiac electrophysiology procedures: A meta‐analysis and review of the literature
title_full_unstemmed The use of minimal fluoroscopy for cardiac electrophysiology procedures: A meta‐analysis and review of the literature
title_short The use of minimal fluoroscopy for cardiac electrophysiology procedures: A meta‐analysis and review of the literature
title_sort use of minimal fluoroscopy for cardiac electrophysiology procedures: a meta‐analysis and review of the literature
topic Clinical Investigations
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8207968/
https://www.ncbi.nlm.nih.gov/pubmed/33998690
http://dx.doi.org/10.1002/clc.23609
work_keys_str_mv AT chianglorrainelokwing theuseofminimalfluoroscopyforcardiacelectrophysiologyproceduresametaanalysisandreviewoftheliterature
AT lichristien theuseofminimalfluoroscopyforcardiacelectrophysiologyproceduresametaanalysisandreviewoftheliterature
AT hongkathrynl theuseofminimalfluoroscopyforcardiacelectrophysiologyproceduresametaanalysisandreviewoftheliterature
AT huiwinsysin theuseofminimalfluoroscopyforcardiacelectrophysiologyproceduresametaanalysisandreviewoftheliterature
AT behszeyi theuseofminimalfluoroscopyforcardiacelectrophysiologyproceduresametaanalysisandreviewoftheliterature
AT gongmengqi theuseofminimalfluoroscopyforcardiacelectrophysiologyproceduresametaanalysisandreviewoftheliterature
AT liutong theuseofminimalfluoroscopyforcardiacelectrophysiologyproceduresametaanalysisandreviewoftheliterature
AT liguangping theuseofminimalfluoroscopyforcardiacelectrophysiologyproceduresametaanalysisandreviewoftheliterature
AT xiayunlong theuseofminimalfluoroscopyforcardiacelectrophysiologyproceduresametaanalysisandreviewoftheliterature
AT hojeffery theuseofminimalfluoroscopyforcardiacelectrophysiologyproceduresametaanalysisandreviewoftheliterature
AT roeverleonardo theuseofminimalfluoroscopyforcardiacelectrophysiologyproceduresametaanalysisandreviewoftheliterature
AT duongsophia theuseofminimalfluoroscopyforcardiacelectrophysiologyproceduresametaanalysisandreviewoftheliterature
AT huanggrace theuseofminimalfluoroscopyforcardiacelectrophysiologyproceduresametaanalysisandreviewoftheliterature
AT tsegary theuseofminimalfluoroscopyforcardiacelectrophysiologyproceduresametaanalysisandreviewoftheliterature
AT baranchukadrian theuseofminimalfluoroscopyforcardiacelectrophysiologyproceduresametaanalysisandreviewoftheliterature
AT gloverbenedictm theuseofminimalfluoroscopyforcardiacelectrophysiologyproceduresametaanalysisandreviewoftheliterature
AT theuseofminimalfluoroscopyforcardiacelectrophysiologyproceduresametaanalysisandreviewoftheliterature
AT chianglorrainelokwing useofminimalfluoroscopyforcardiacelectrophysiologyproceduresametaanalysisandreviewoftheliterature
AT lichristien useofminimalfluoroscopyforcardiacelectrophysiologyproceduresametaanalysisandreviewoftheliterature
AT hongkathrynl useofminimalfluoroscopyforcardiacelectrophysiologyproceduresametaanalysisandreviewoftheliterature
AT huiwinsysin useofminimalfluoroscopyforcardiacelectrophysiologyproceduresametaanalysisandreviewoftheliterature
AT behszeyi useofminimalfluoroscopyforcardiacelectrophysiologyproceduresametaanalysisandreviewoftheliterature
AT gongmengqi useofminimalfluoroscopyforcardiacelectrophysiologyproceduresametaanalysisandreviewoftheliterature
AT liutong useofminimalfluoroscopyforcardiacelectrophysiologyproceduresametaanalysisandreviewoftheliterature
AT liguangping useofminimalfluoroscopyforcardiacelectrophysiologyproceduresametaanalysisandreviewoftheliterature
AT xiayunlong useofminimalfluoroscopyforcardiacelectrophysiologyproceduresametaanalysisandreviewoftheliterature
AT hojeffery useofminimalfluoroscopyforcardiacelectrophysiologyproceduresametaanalysisandreviewoftheliterature
AT roeverleonardo useofminimalfluoroscopyforcardiacelectrophysiologyproceduresametaanalysisandreviewoftheliterature
AT duongsophia useofminimalfluoroscopyforcardiacelectrophysiologyproceduresametaanalysisandreviewoftheliterature
AT huanggrace useofminimalfluoroscopyforcardiacelectrophysiologyproceduresametaanalysisandreviewoftheliterature
AT tsegary useofminimalfluoroscopyforcardiacelectrophysiologyproceduresametaanalysisandreviewoftheliterature
AT baranchukadrian useofminimalfluoroscopyforcardiacelectrophysiologyproceduresametaanalysisandreviewoftheliterature
AT gloverbenedictm useofminimalfluoroscopyforcardiacelectrophysiologyproceduresametaanalysisandreviewoftheliterature
AT useofminimalfluoroscopyforcardiacelectrophysiologyproceduresametaanalysisandreviewoftheliterature