A novel approach to identification and excision of a persistent sinus tract following a rectus fascial sling: A case report

BACKGROUND: While Gore-Tex® sutures have excellent handling and cause minimal fibroblast activity and a less inflammatory response compared with other materials, they carry a risk of persistent sinus tract formation. CASE: A patient underwent an autologous rectus fascial sling using Gore-Tex® and we...

Descripción completa

Detalles Bibliográficos
Autores principales: Winkelman, William.D., Sasson, Jacques.P., Elkadry, Eman
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8209167/
https://www.ncbi.nlm.nih.gov/pubmed/34168964
http://dx.doi.org/10.1016/j.crwh.2021.e00333
Descripción
Sumario:BACKGROUND: While Gore-Tex® sutures have excellent handling and cause minimal fibroblast activity and a less inflammatory response compared with other materials, they carry a risk of persistent sinus tract formation. CASE: A patient underwent an autologous rectus fascial sling using Gore-Tex® and we describe a novel technique for identification and excision of the sinus tract. CONCLUSION: Preoperative imaging and staining of the sinus tract with methylene blue can aid in successful identification of the tract during surgery and may improve rates of successful treatment.