The largest secure corridor of the infra-acetabular screw—a 3-D axial perspective analysis

BACKGROUND: The infra-acetabular screw which is placed from the pubis to the ischium can be used as a special positional screw of the posterior column of the acetabulum. This study was performed to simulate the surgical procedure and obtain the ideal insertion point, diameter, length and angle of th...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhao, Bei, Zhang, Wei, Li, Hao, Han, Liren, Han, Shizhang, Yang, Xiaofei, Yan, Jun, Mu, Weidong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8210356/
https://www.ncbi.nlm.nih.gov/pubmed/34134690
http://dx.doi.org/10.1186/s12891-021-04433-z
_version_ 1783709293753663488
author Zhao, Bei
Zhang, Wei
Li, Hao
Han, Liren
Han, Shizhang
Yang, Xiaofei
Yan, Jun
Mu, Weidong
author_facet Zhao, Bei
Zhang, Wei
Li, Hao
Han, Liren
Han, Shizhang
Yang, Xiaofei
Yan, Jun
Mu, Weidong
author_sort Zhao, Bei
collection PubMed
description BACKGROUND: The infra-acetabular screw which is placed from the pubis to the ischium can be used as a special positional screw of the posterior column of the acetabulum. This study was performed to simulate the surgical procedure and obtain the ideal insertion point, diameter, length and angle of the screw through the method of axial perspective in Chinese patients. METHODS: We randomly collected the pelvic computed tomography (CT) scans of 200 adults. DICOM-formatted CT-scan images were imported into Mimics software to establish the 3D digital model of the right semi-pelvic was established. A virtual cylinder representing the screw was placed from the pubis to the ischium to fix the posterior column. The largest secure diameter and length of the virtual screw were measured and the position of the insertion point and the directions of the screw were also researched. RESULTS: The screw insertion safe zone exhibits an irregular shape of “tear drop” in the reconstructed pelvic model. The mean maximum diameter of screws was 5.01 ± 1.28 mm, and the mean maximum length of screws was 93.99 ± 8.92 mm. The screw insertion corridor with the least diameter 3.5 mm was found in 94 of 100 males (94%) and 86 of 100 females (86%). We found gender-dependent differences for the mean maximum diameter and the maximum length of the screw. There was statistically significant difference between genders in the position of insertion point. CONCLUSIONS: In this study, we suggest an individual preoperative 3D reconstruction simulation to develop better screw placement plans, which provides a valuable guideline for seeking the largest secure corridor of infra-acetabular screw. Further biomechanical studies are needed to verify the function of the screw.
format Online
Article
Text
id pubmed-8210356
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-82103562021-06-17 The largest secure corridor of the infra-acetabular screw—a 3-D axial perspective analysis Zhao, Bei Zhang, Wei Li, Hao Han, Liren Han, Shizhang Yang, Xiaofei Yan, Jun Mu, Weidong BMC Musculoskelet Disord Research Article BACKGROUND: The infra-acetabular screw which is placed from the pubis to the ischium can be used as a special positional screw of the posterior column of the acetabulum. This study was performed to simulate the surgical procedure and obtain the ideal insertion point, diameter, length and angle of the screw through the method of axial perspective in Chinese patients. METHODS: We randomly collected the pelvic computed tomography (CT) scans of 200 adults. DICOM-formatted CT-scan images were imported into Mimics software to establish the 3D digital model of the right semi-pelvic was established. A virtual cylinder representing the screw was placed from the pubis to the ischium to fix the posterior column. The largest secure diameter and length of the virtual screw were measured and the position of the insertion point and the directions of the screw were also researched. RESULTS: The screw insertion safe zone exhibits an irregular shape of “tear drop” in the reconstructed pelvic model. The mean maximum diameter of screws was 5.01 ± 1.28 mm, and the mean maximum length of screws was 93.99 ± 8.92 mm. The screw insertion corridor with the least diameter 3.5 mm was found in 94 of 100 males (94%) and 86 of 100 females (86%). We found gender-dependent differences for the mean maximum diameter and the maximum length of the screw. There was statistically significant difference between genders in the position of insertion point. CONCLUSIONS: In this study, we suggest an individual preoperative 3D reconstruction simulation to develop better screw placement plans, which provides a valuable guideline for seeking the largest secure corridor of infra-acetabular screw. Further biomechanical studies are needed to verify the function of the screw. BioMed Central 2021-06-16 /pmc/articles/PMC8210356/ /pubmed/34134690 http://dx.doi.org/10.1186/s12891-021-04433-z Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Zhao, Bei
Zhang, Wei
Li, Hao
Han, Liren
Han, Shizhang
Yang, Xiaofei
Yan, Jun
Mu, Weidong
The largest secure corridor of the infra-acetabular screw—a 3-D axial perspective analysis
title The largest secure corridor of the infra-acetabular screw—a 3-D axial perspective analysis
title_full The largest secure corridor of the infra-acetabular screw—a 3-D axial perspective analysis
title_fullStr The largest secure corridor of the infra-acetabular screw—a 3-D axial perspective analysis
title_full_unstemmed The largest secure corridor of the infra-acetabular screw—a 3-D axial perspective analysis
title_short The largest secure corridor of the infra-acetabular screw—a 3-D axial perspective analysis
title_sort largest secure corridor of the infra-acetabular screw—a 3-d axial perspective analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8210356/
https://www.ncbi.nlm.nih.gov/pubmed/34134690
http://dx.doi.org/10.1186/s12891-021-04433-z
work_keys_str_mv AT zhaobei thelargestsecurecorridoroftheinfraacetabularscrewa3daxialperspectiveanalysis
AT zhangwei thelargestsecurecorridoroftheinfraacetabularscrewa3daxialperspectiveanalysis
AT lihao thelargestsecurecorridoroftheinfraacetabularscrewa3daxialperspectiveanalysis
AT hanliren thelargestsecurecorridoroftheinfraacetabularscrewa3daxialperspectiveanalysis
AT hanshizhang thelargestsecurecorridoroftheinfraacetabularscrewa3daxialperspectiveanalysis
AT yangxiaofei thelargestsecurecorridoroftheinfraacetabularscrewa3daxialperspectiveanalysis
AT yanjun thelargestsecurecorridoroftheinfraacetabularscrewa3daxialperspectiveanalysis
AT muweidong thelargestsecurecorridoroftheinfraacetabularscrewa3daxialperspectiveanalysis
AT zhaobei largestsecurecorridoroftheinfraacetabularscrewa3daxialperspectiveanalysis
AT zhangwei largestsecurecorridoroftheinfraacetabularscrewa3daxialperspectiveanalysis
AT lihao largestsecurecorridoroftheinfraacetabularscrewa3daxialperspectiveanalysis
AT hanliren largestsecurecorridoroftheinfraacetabularscrewa3daxialperspectiveanalysis
AT hanshizhang largestsecurecorridoroftheinfraacetabularscrewa3daxialperspectiveanalysis
AT yangxiaofei largestsecurecorridoroftheinfraacetabularscrewa3daxialperspectiveanalysis
AT yanjun largestsecurecorridoroftheinfraacetabularscrewa3daxialperspectiveanalysis
AT muweidong largestsecurecorridoroftheinfraacetabularscrewa3daxialperspectiveanalysis