Cargando…
Fluoroscopy-guided shaped endobiliary biopsy at endoscopic retrograde cholangiography can accurately diagnose biliary neoplasia: Results from a large cohort
Background and study aims The sensitivity of using standard endobiliary forceps biopsy to diagnose neoplastic biliary lesions remains low. We have developed a unique biopsy approach, termed fluoroscopy-guided, shaped endobiliary biopsy (FSEB), in which the biopsy forceps are modified to improve dia...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Georg Thieme Verlag KG
2021
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8211481/ https://www.ncbi.nlm.nih.gov/pubmed/34222628 http://dx.doi.org/10.1055/a-1399-8031 |
_version_ | 1783709474292236288 |
---|---|
author | Wang, Bao-can Wang, Kelly K. Paul, Navin Jayaraman, Vijay Wang, Qiang Abboud, Yazan Jamil, Laith H. Gaddam, Srinivas Lo, Simon K. |
author_facet | Wang, Bao-can Wang, Kelly K. Paul, Navin Jayaraman, Vijay Wang, Qiang Abboud, Yazan Jamil, Laith H. Gaddam, Srinivas Lo, Simon K. |
author_sort | Wang, Bao-can |
collection | PubMed |
description | Background and study aims The sensitivity of using standard endobiliary forceps biopsy to diagnose neoplastic biliary lesions remains low. We have developed a unique biopsy approach, termed fluoroscopy-guided, shaped endobiliary biopsy (FSEB), in which the biopsy forceps are modified to improve diagnostic yield. In this study, we evaluate the diagnostic characteristics of FSEB for endobiliary lesions at endoscopic retrograde cholangiography (ERC). Patients and methods Consecutive patients undergoing FSEB between 1/2001 and 12/2014 were retrospectively enrolled. The identification of neoplastic lesions with FSEB, was the primary endpoint. The gold standard of neoplasia was histopathology, cytology or surgical histopathology. The benign cases were followed up for one year. Results A total of 204 patients undergoing 250 biopsy sessions by FSEB were analyzed. Per-patient analysis was performed and FSEB showed 81.1 % sensitivity and 88.2 % accuracy. FSEB detection of proximal biliary lesions was more sensitive (91.1 % vs 73.2 %, P < 0.01) and accurate (94.9 % vs 82.2 %, P < 0.01) compared to distal lesions. No complications from FSEB were reported. Conclusions FSEB shows high accuracy for diagnosis of neoplasia in biliary strictures, especially for proximal lesions. Future prospective randomized controlled studies are merited to further validate the role of FSEB as the first-line sampling tool for evaluation of biliary neoplasm. |
format | Online Article Text |
id | pubmed-8211481 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Georg Thieme Verlag KG |
record_format | MEDLINE/PubMed |
spelling | pubmed-82114812021-07-01 Fluoroscopy-guided shaped endobiliary biopsy at endoscopic retrograde cholangiography can accurately diagnose biliary neoplasia: Results from a large cohort Wang, Bao-can Wang, Kelly K. Paul, Navin Jayaraman, Vijay Wang, Qiang Abboud, Yazan Jamil, Laith H. Gaddam, Srinivas Lo, Simon K. Endosc Int Open Background and study aims The sensitivity of using standard endobiliary forceps biopsy to diagnose neoplastic biliary lesions remains low. We have developed a unique biopsy approach, termed fluoroscopy-guided, shaped endobiliary biopsy (FSEB), in which the biopsy forceps are modified to improve diagnostic yield. In this study, we evaluate the diagnostic characteristics of FSEB for endobiliary lesions at endoscopic retrograde cholangiography (ERC). Patients and methods Consecutive patients undergoing FSEB between 1/2001 and 12/2014 were retrospectively enrolled. The identification of neoplastic lesions with FSEB, was the primary endpoint. The gold standard of neoplasia was histopathology, cytology or surgical histopathology. The benign cases were followed up for one year. Results A total of 204 patients undergoing 250 biopsy sessions by FSEB were analyzed. Per-patient analysis was performed and FSEB showed 81.1 % sensitivity and 88.2 % accuracy. FSEB detection of proximal biliary lesions was more sensitive (91.1 % vs 73.2 %, P < 0.01) and accurate (94.9 % vs 82.2 %, P < 0.01) compared to distal lesions. No complications from FSEB were reported. Conclusions FSEB shows high accuracy for diagnosis of neoplasia in biliary strictures, especially for proximal lesions. Future prospective randomized controlled studies are merited to further validate the role of FSEB as the first-line sampling tool for evaluation of biliary neoplasm. Georg Thieme Verlag KG 2021-07 2021-06-17 /pmc/articles/PMC8211481/ /pubmed/34222628 http://dx.doi.org/10.1055/a-1399-8031 Text en The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License, which permits unrestricted reproduction and distribution, for non-commercial purposes only; and use and reproduction, but not distribution, of adapted material for non-commercial purposes only, provided the original work is properly cited. |
spellingShingle | Wang, Bao-can Wang, Kelly K. Paul, Navin Jayaraman, Vijay Wang, Qiang Abboud, Yazan Jamil, Laith H. Gaddam, Srinivas Lo, Simon K. Fluoroscopy-guided shaped endobiliary biopsy at endoscopic retrograde cholangiography can accurately diagnose biliary neoplasia: Results from a large cohort |
title | Fluoroscopy-guided shaped endobiliary biopsy at endoscopic retrograde cholangiography can accurately diagnose biliary neoplasia: Results from a large cohort |
title_full | Fluoroscopy-guided shaped endobiliary biopsy at endoscopic retrograde cholangiography can accurately diagnose biliary neoplasia: Results from a large cohort |
title_fullStr | Fluoroscopy-guided shaped endobiliary biopsy at endoscopic retrograde cholangiography can accurately diagnose biliary neoplasia: Results from a large cohort |
title_full_unstemmed | Fluoroscopy-guided shaped endobiliary biopsy at endoscopic retrograde cholangiography can accurately diagnose biliary neoplasia: Results from a large cohort |
title_short | Fluoroscopy-guided shaped endobiliary biopsy at endoscopic retrograde cholangiography can accurately diagnose biliary neoplasia: Results from a large cohort |
title_sort | fluoroscopy-guided shaped endobiliary biopsy at endoscopic retrograde cholangiography can accurately diagnose biliary neoplasia: results from a large cohort |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8211481/ https://www.ncbi.nlm.nih.gov/pubmed/34222628 http://dx.doi.org/10.1055/a-1399-8031 |
work_keys_str_mv | AT wangbaocan fluoroscopyguidedshapedendobiliarybiopsyatendoscopicretrogradecholangiographycanaccuratelydiagnosebiliaryneoplasiaresultsfromalargecohort AT wangkellyk fluoroscopyguidedshapedendobiliarybiopsyatendoscopicretrogradecholangiographycanaccuratelydiagnosebiliaryneoplasiaresultsfromalargecohort AT paulnavin fluoroscopyguidedshapedendobiliarybiopsyatendoscopicretrogradecholangiographycanaccuratelydiagnosebiliaryneoplasiaresultsfromalargecohort AT jayaramanvijay fluoroscopyguidedshapedendobiliarybiopsyatendoscopicretrogradecholangiographycanaccuratelydiagnosebiliaryneoplasiaresultsfromalargecohort AT wangqiang fluoroscopyguidedshapedendobiliarybiopsyatendoscopicretrogradecholangiographycanaccuratelydiagnosebiliaryneoplasiaresultsfromalargecohort AT abboudyazan fluoroscopyguidedshapedendobiliarybiopsyatendoscopicretrogradecholangiographycanaccuratelydiagnosebiliaryneoplasiaresultsfromalargecohort AT jamillaithh fluoroscopyguidedshapedendobiliarybiopsyatendoscopicretrogradecholangiographycanaccuratelydiagnosebiliaryneoplasiaresultsfromalargecohort AT gaddamsrinivas fluoroscopyguidedshapedendobiliarybiopsyatendoscopicretrogradecholangiographycanaccuratelydiagnosebiliaryneoplasiaresultsfromalargecohort AT losimonk fluoroscopyguidedshapedendobiliarybiopsyatendoscopicretrogradecholangiographycanaccuratelydiagnosebiliaryneoplasiaresultsfromalargecohort |