Cargando…
Simple feedback of colonoscopy performance improved the number of adenomas per colonoscopy and serrated polyp detection rate
Background and study aims High-quality endoscopy requires improvement of not only the adenoma detection rate (ADR) but also the serrated polyp (SP) detection rate and the mean number of adenomas per positive procedure (MAP +). We evaluated whether a simple feedback of colonoscopy performance improv...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Georg Thieme Verlag KG
2021
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8211485/ https://www.ncbi.nlm.nih.gov/pubmed/34222627 http://dx.doi.org/10.1055/a-1393-5469 |
_version_ | 1783709475234906112 |
---|---|
author | Toyoshima, Osamu Yoshida, Shuntaro Nishizawa, Toshihiro Yamakawa, Tadahiro Arano, Toru Isomura, Yoshihiro Kanazawa, Takamitsu Ando, Hidehiko Tsuji, Yosuke Koike, Kazuhiko |
author_facet | Toyoshima, Osamu Yoshida, Shuntaro Nishizawa, Toshihiro Yamakawa, Tadahiro Arano, Toru Isomura, Yoshihiro Kanazawa, Takamitsu Ando, Hidehiko Tsuji, Yosuke Koike, Kazuhiko |
author_sort | Toyoshima, Osamu |
collection | PubMed |
description | Background and study aims High-quality endoscopy requires improvement of not only the adenoma detection rate (ADR) but also the serrated polyp (SP) detection rate and the mean number of adenomas per positive procedure (MAP +). We evaluated whether a simple feedback of colonoscopy performance improves those quality indicators using propensity-score matching. Patients and methods Eleven endoscopists were evaluated regarding colonoscopy performance including ADRs, SP detection rates, mean numbers of adenomas per procedure (MAPs), and MAPs + with their ranking in the clinic. Endoscopic performance was compared before and after the feedback. Results Colonoscopies were performed for 874 patients before the feedback and 1,272 patients after the feedback. Using propensity-score matching, 803 patients before the feedback and 803 patients after the feedback were matched. ADR after the feedback was significantly higher than that before the feedback (50.8 % and 40.8 %, respectively). MAP after feedback was significantly larger than that before the feedback (0.92 and 0.69, respectively), as well as MAP + (1.96 and 1.69, respectively). Clinically significant SP detection rate was also improved from 10.0 % to 14.9 %. Conclusions Feedback including ADR, MAP, MAP +, and clinically significant SR detection rate could improve on those quality indicators. Further studies are needed to effectively prevent colorectal cancer in colonoscopy practice. |
format | Online Article Text |
id | pubmed-8211485 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Georg Thieme Verlag KG |
record_format | MEDLINE/PubMed |
spelling | pubmed-82114852021-07-01 Simple feedback of colonoscopy performance improved the number of adenomas per colonoscopy and serrated polyp detection rate Toyoshima, Osamu Yoshida, Shuntaro Nishizawa, Toshihiro Yamakawa, Tadahiro Arano, Toru Isomura, Yoshihiro Kanazawa, Takamitsu Ando, Hidehiko Tsuji, Yosuke Koike, Kazuhiko Endosc Int Open Background and study aims High-quality endoscopy requires improvement of not only the adenoma detection rate (ADR) but also the serrated polyp (SP) detection rate and the mean number of adenomas per positive procedure (MAP +). We evaluated whether a simple feedback of colonoscopy performance improves those quality indicators using propensity-score matching. Patients and methods Eleven endoscopists were evaluated regarding colonoscopy performance including ADRs, SP detection rates, mean numbers of adenomas per procedure (MAPs), and MAPs + with their ranking in the clinic. Endoscopic performance was compared before and after the feedback. Results Colonoscopies were performed for 874 patients before the feedback and 1,272 patients after the feedback. Using propensity-score matching, 803 patients before the feedback and 803 patients after the feedback were matched. ADR after the feedback was significantly higher than that before the feedback (50.8 % and 40.8 %, respectively). MAP after feedback was significantly larger than that before the feedback (0.92 and 0.69, respectively), as well as MAP + (1.96 and 1.69, respectively). Clinically significant SP detection rate was also improved from 10.0 % to 14.9 %. Conclusions Feedback including ADR, MAP, MAP +, and clinically significant SR detection rate could improve on those quality indicators. Further studies are needed to effectively prevent colorectal cancer in colonoscopy practice. Georg Thieme Verlag KG 2021-07 2021-06-17 /pmc/articles/PMC8211485/ /pubmed/34222627 http://dx.doi.org/10.1055/a-1393-5469 Text en The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License, which permits unrestricted reproduction and distribution, for non-commercial purposes only; and use and reproduction, but not distribution, of adapted material for non-commercial purposes only, provided the original work is properly cited. |
spellingShingle | Toyoshima, Osamu Yoshida, Shuntaro Nishizawa, Toshihiro Yamakawa, Tadahiro Arano, Toru Isomura, Yoshihiro Kanazawa, Takamitsu Ando, Hidehiko Tsuji, Yosuke Koike, Kazuhiko Simple feedback of colonoscopy performance improved the number of adenomas per colonoscopy and serrated polyp detection rate |
title | Simple feedback of colonoscopy performance improved the number of adenomas per colonoscopy and serrated polyp detection rate |
title_full | Simple feedback of colonoscopy performance improved the number of adenomas per colonoscopy and serrated polyp detection rate |
title_fullStr | Simple feedback of colonoscopy performance improved the number of adenomas per colonoscopy and serrated polyp detection rate |
title_full_unstemmed | Simple feedback of colonoscopy performance improved the number of adenomas per colonoscopy and serrated polyp detection rate |
title_short | Simple feedback of colonoscopy performance improved the number of adenomas per colonoscopy and serrated polyp detection rate |
title_sort | simple feedback of colonoscopy performance improved the number of adenomas per colonoscopy and serrated polyp detection rate |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8211485/ https://www.ncbi.nlm.nih.gov/pubmed/34222627 http://dx.doi.org/10.1055/a-1393-5469 |
work_keys_str_mv | AT toyoshimaosamu simplefeedbackofcolonoscopyperformanceimprovedthenumberofadenomaspercolonoscopyandserratedpolypdetectionrate AT yoshidashuntaro simplefeedbackofcolonoscopyperformanceimprovedthenumberofadenomaspercolonoscopyandserratedpolypdetectionrate AT nishizawatoshihiro simplefeedbackofcolonoscopyperformanceimprovedthenumberofadenomaspercolonoscopyandserratedpolypdetectionrate AT yamakawatadahiro simplefeedbackofcolonoscopyperformanceimprovedthenumberofadenomaspercolonoscopyandserratedpolypdetectionrate AT aranotoru simplefeedbackofcolonoscopyperformanceimprovedthenumberofadenomaspercolonoscopyandserratedpolypdetectionrate AT isomurayoshihiro simplefeedbackofcolonoscopyperformanceimprovedthenumberofadenomaspercolonoscopyandserratedpolypdetectionrate AT kanazawatakamitsu simplefeedbackofcolonoscopyperformanceimprovedthenumberofadenomaspercolonoscopyandserratedpolypdetectionrate AT andohidehiko simplefeedbackofcolonoscopyperformanceimprovedthenumberofadenomaspercolonoscopyandserratedpolypdetectionrate AT tsujiyosuke simplefeedbackofcolonoscopyperformanceimprovedthenumberofadenomaspercolonoscopyandserratedpolypdetectionrate AT koikekazuhiko simplefeedbackofcolonoscopyperformanceimprovedthenumberofadenomaspercolonoscopyandserratedpolypdetectionrate |