Cargando…

Simple feedback of colonoscopy performance improved the number of adenomas per colonoscopy and serrated polyp detection rate

Background and study aims  High-quality endoscopy requires improvement of not only the adenoma detection rate (ADR) but also the serrated polyp (SP) detection rate and the mean number of adenomas per positive procedure (MAP +). We evaluated whether a simple feedback of colonoscopy performance improv...

Descripción completa

Detalles Bibliográficos
Autores principales: Toyoshima, Osamu, Yoshida, Shuntaro, Nishizawa, Toshihiro, Yamakawa, Tadahiro, Arano, Toru, Isomura, Yoshihiro, Kanazawa, Takamitsu, Ando, Hidehiko, Tsuji, Yosuke, Koike, Kazuhiko
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Georg Thieme Verlag KG 2021
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8211485/
https://www.ncbi.nlm.nih.gov/pubmed/34222627
http://dx.doi.org/10.1055/a-1393-5469
_version_ 1783709475234906112
author Toyoshima, Osamu
Yoshida, Shuntaro
Nishizawa, Toshihiro
Yamakawa, Tadahiro
Arano, Toru
Isomura, Yoshihiro
Kanazawa, Takamitsu
Ando, Hidehiko
Tsuji, Yosuke
Koike, Kazuhiko
author_facet Toyoshima, Osamu
Yoshida, Shuntaro
Nishizawa, Toshihiro
Yamakawa, Tadahiro
Arano, Toru
Isomura, Yoshihiro
Kanazawa, Takamitsu
Ando, Hidehiko
Tsuji, Yosuke
Koike, Kazuhiko
author_sort Toyoshima, Osamu
collection PubMed
description Background and study aims  High-quality endoscopy requires improvement of not only the adenoma detection rate (ADR) but also the serrated polyp (SP) detection rate and the mean number of adenomas per positive procedure (MAP +). We evaluated whether a simple feedback of colonoscopy performance improves those quality indicators using propensity-score matching. Patients and methods  Eleven endoscopists were evaluated regarding colonoscopy performance including ADRs, SP detection rates, mean numbers of adenomas per procedure (MAPs), and MAPs + with their ranking in the clinic. Endoscopic performance was compared before and after the feedback. Results  Colonoscopies were performed for 874 patients before the feedback and 1,272 patients after the feedback. Using propensity-score matching, 803 patients before the feedback and 803 patients after the feedback were matched. ADR after the feedback was significantly higher than that before the feedback (50.8 % and 40.8 %, respectively). MAP after feedback was significantly larger than that before the feedback (0.92 and 0.69, respectively), as well as MAP + (1.96 and 1.69, respectively). Clinically significant SP detection rate was also improved from 10.0 % to 14.9 %. Conclusions  Feedback including ADR, MAP, MAP +, and clinically significant SR detection rate could improve on those quality indicators. Further studies are needed to effectively prevent colorectal cancer in colonoscopy practice.
format Online
Article
Text
id pubmed-8211485
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Georg Thieme Verlag KG
record_format MEDLINE/PubMed
spelling pubmed-82114852021-07-01 Simple feedback of colonoscopy performance improved the number of adenomas per colonoscopy and serrated polyp detection rate Toyoshima, Osamu Yoshida, Shuntaro Nishizawa, Toshihiro Yamakawa, Tadahiro Arano, Toru Isomura, Yoshihiro Kanazawa, Takamitsu Ando, Hidehiko Tsuji, Yosuke Koike, Kazuhiko Endosc Int Open Background and study aims  High-quality endoscopy requires improvement of not only the adenoma detection rate (ADR) but also the serrated polyp (SP) detection rate and the mean number of adenomas per positive procedure (MAP +). We evaluated whether a simple feedback of colonoscopy performance improves those quality indicators using propensity-score matching. Patients and methods  Eleven endoscopists were evaluated regarding colonoscopy performance including ADRs, SP detection rates, mean numbers of adenomas per procedure (MAPs), and MAPs + with their ranking in the clinic. Endoscopic performance was compared before and after the feedback. Results  Colonoscopies were performed for 874 patients before the feedback and 1,272 patients after the feedback. Using propensity-score matching, 803 patients before the feedback and 803 patients after the feedback were matched. ADR after the feedback was significantly higher than that before the feedback (50.8 % and 40.8 %, respectively). MAP after feedback was significantly larger than that before the feedback (0.92 and 0.69, respectively), as well as MAP + (1.96 and 1.69, respectively). Clinically significant SP detection rate was also improved from 10.0 % to 14.9 %. Conclusions  Feedback including ADR, MAP, MAP +, and clinically significant SR detection rate could improve on those quality indicators. Further studies are needed to effectively prevent colorectal cancer in colonoscopy practice. Georg Thieme Verlag KG 2021-07 2021-06-17 /pmc/articles/PMC8211485/ /pubmed/34222627 http://dx.doi.org/10.1055/a-1393-5469 Text en The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License, which permits unrestricted reproduction and distribution, for non-commercial purposes only; and use and reproduction, but not distribution, of adapted material for non-commercial purposes only, provided the original work is properly cited.
spellingShingle Toyoshima, Osamu
Yoshida, Shuntaro
Nishizawa, Toshihiro
Yamakawa, Tadahiro
Arano, Toru
Isomura, Yoshihiro
Kanazawa, Takamitsu
Ando, Hidehiko
Tsuji, Yosuke
Koike, Kazuhiko
Simple feedback of colonoscopy performance improved the number of adenomas per colonoscopy and serrated polyp detection rate
title Simple feedback of colonoscopy performance improved the number of adenomas per colonoscopy and serrated polyp detection rate
title_full Simple feedback of colonoscopy performance improved the number of adenomas per colonoscopy and serrated polyp detection rate
title_fullStr Simple feedback of colonoscopy performance improved the number of adenomas per colonoscopy and serrated polyp detection rate
title_full_unstemmed Simple feedback of colonoscopy performance improved the number of adenomas per colonoscopy and serrated polyp detection rate
title_short Simple feedback of colonoscopy performance improved the number of adenomas per colonoscopy and serrated polyp detection rate
title_sort simple feedback of colonoscopy performance improved the number of adenomas per colonoscopy and serrated polyp detection rate
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8211485/
https://www.ncbi.nlm.nih.gov/pubmed/34222627
http://dx.doi.org/10.1055/a-1393-5469
work_keys_str_mv AT toyoshimaosamu simplefeedbackofcolonoscopyperformanceimprovedthenumberofadenomaspercolonoscopyandserratedpolypdetectionrate
AT yoshidashuntaro simplefeedbackofcolonoscopyperformanceimprovedthenumberofadenomaspercolonoscopyandserratedpolypdetectionrate
AT nishizawatoshihiro simplefeedbackofcolonoscopyperformanceimprovedthenumberofadenomaspercolonoscopyandserratedpolypdetectionrate
AT yamakawatadahiro simplefeedbackofcolonoscopyperformanceimprovedthenumberofadenomaspercolonoscopyandserratedpolypdetectionrate
AT aranotoru simplefeedbackofcolonoscopyperformanceimprovedthenumberofadenomaspercolonoscopyandserratedpolypdetectionrate
AT isomurayoshihiro simplefeedbackofcolonoscopyperformanceimprovedthenumberofadenomaspercolonoscopyandserratedpolypdetectionrate
AT kanazawatakamitsu simplefeedbackofcolonoscopyperformanceimprovedthenumberofadenomaspercolonoscopyandserratedpolypdetectionrate
AT andohidehiko simplefeedbackofcolonoscopyperformanceimprovedthenumberofadenomaspercolonoscopyandserratedpolypdetectionrate
AT tsujiyosuke simplefeedbackofcolonoscopyperformanceimprovedthenumberofadenomaspercolonoscopyandserratedpolypdetectionrate
AT koikekazuhiko simplefeedbackofcolonoscopyperformanceimprovedthenumberofadenomaspercolonoscopyandserratedpolypdetectionrate