Comparing Ventilation Parameters for COVID-19 Patients Using Both Long-Term ICU and Anesthetic Ventilators in Times of Shortage

In the first months of the COVID-19 pandemic in Europe, many patients were treated in hospitals using mechanical ventilation. However, due to a shortage of ICU ventilators, hospitals worldwide needed to deploy anesthesia machines for ICU ventilation (which is off-label use). A joint guidance was wri...

Descripción completa

Detalles Bibliográficos
Autores principales: Dijkman, Wouter M., van Acht, Niels M. C., van Akkeren, Jesse P., Bhagwanbali, Rhasna C. D., van Pul, Carola
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8212026/
https://www.ncbi.nlm.nih.gov/pubmed/34134571
http://dx.doi.org/10.1177/08850666211024911
Descripción
Sumario:In the first months of the COVID-19 pandemic in Europe, many patients were treated in hospitals using mechanical ventilation. However, due to a shortage of ICU ventilators, hospitals worldwide needed to deploy anesthesia machines for ICU ventilation (which is off-label use). A joint guidance was written to apply anesthesia machines for long-term ventilation. The goal of this research is to retrospectively evaluate the differences in measurable ventilation parameters between the ICU ventilator and the anesthesia machine as used for COVID-19 patients. In this study, we included 32 patients treated in March and April 2020, who had more than 3 days of mechanical ventilation, either in the regular ICU with ICU ventilators (Hamilton S1), or in the temporary emergency ICU with anesthetic ventilators (Aisys, GE). The data acquired during regular clinical treatment was collected from the Patient Data Management Systems. Available ventilation parameters (pressures and volumes: PEEP, P(peak) , P(insp) , V(tidal) ), monitored parameters EtCO(2), SpO(2) , derived compliance C, and resistance R were processed and analyzed. A sub-analysis was performed to compare closed-loop ventilation (INTELLiVENT-ASV) to other ventilation modes. The results showed no major differences in the compared parameters, except for P(insp) . PEEP was reduced over time in the with Hamilton treated patients. This is most likely attributed to changing clinical protocol as more clinical experience and literature became available. A comparison of compliance between the 2 ventilators could not be made due to variances in the measurement of compliance. Closed loop ventilation could be used in 79% of the time, resulting in more stable EtCO(2) . From the analysis it can be concluded that the off-label usage of the anesthetic ventilator in our hospital did not result in differences in ventilation parameters compared to the ICU treatment in the first 4 days of ventilation.