Cargando…

Microscope-Integrated OCT-Guided Volumetric Measurements of Subretinal Blebs Created by a Suprachoroidal Approach

PURPOSE: To investigate the use of imaging modalities in the volumetric measurement of the subretinal space and examine the volume of subretinal blebs created by a subretinal drug delivery device utilizing microscope-integrated optical coherence tomography (MIOCT). METHODS: An MIOCT image-based volu...

Descripción completa

Detalles Bibliográficos
Autores principales: Sastry, Ananth, Li, Jianwei D., Raynor, William, Viehland, Christian, Song, Zhenxi, Xu, Liangyu, Farsiu, Sina, Izatt, Joseph A., Toth, Cynthia A., Vajzovic, Lejla
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8212437/
https://www.ncbi.nlm.nih.gov/pubmed/34137836
http://dx.doi.org/10.1167/tvst.10.7.24
_version_ 1783709638670155776
author Sastry, Ananth
Li, Jianwei D.
Raynor, William
Viehland, Christian
Song, Zhenxi
Xu, Liangyu
Farsiu, Sina
Izatt, Joseph A.
Toth, Cynthia A.
Vajzovic, Lejla
author_facet Sastry, Ananth
Li, Jianwei D.
Raynor, William
Viehland, Christian
Song, Zhenxi
Xu, Liangyu
Farsiu, Sina
Izatt, Joseph A.
Toth, Cynthia A.
Vajzovic, Lejla
author_sort Sastry, Ananth
collection PubMed
description PURPOSE: To investigate the use of imaging modalities in the volumetric measurement of the subretinal space and examine the volume of subretinal blebs created by a subretinal drug delivery device utilizing microscope-integrated optical coherence tomography (MIOCT). METHODS: An MIOCT image-based volume measurement method was developed and assessed for accuracy and reproducibility by imaging ceramic spheres of known size that were surgically implanted into ex vivo porcine eyes. This method was then used to measure subretinal blebs created in 10 porcine eyes by injection of balanced salt solution utilizing a subretinal delivery device via a suprachoroidal cannula. Bleb volumes obtained from MIOCT were compared to the intended injection volume. RESULTS: Validation of image-based volume measurements of ceramic spheres showed accuracy to ±0.029 µL (5.6%) for objects imaged over the posterior pole and ±0.025 µL (4.8%) over peripheral retina. The mean expected injection volume from extraocular tests of the suprachoroidal cannula was 66.44 µL (σ = 2.4 µL). The mean injection volume as measured by the MIOCT imaging method was 54.8 µL (σ = 12.3 µL), or 82.48% of expected injection volume. CONCLUSIONS: MIOCT can measure the volume of subretinal blebs with accuracy and precision. The novel suprachoroidal approach using a subretinal delivery device was able to deliver greater than 80% of expected injection volume into the subretinal space, as assessed by MIOCT. TRANSLATIONAL RELEVANCE: MIOCT provides a method for visualization, and analysis of images enables surgeons to quantify and evaluate the success of subretinal drug delivery via a suprachoroidal approach.
format Online
Article
Text
id pubmed-8212437
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-82124372021-06-22 Microscope-Integrated OCT-Guided Volumetric Measurements of Subretinal Blebs Created by a Suprachoroidal Approach Sastry, Ananth Li, Jianwei D. Raynor, William Viehland, Christian Song, Zhenxi Xu, Liangyu Farsiu, Sina Izatt, Joseph A. Toth, Cynthia A. Vajzovic, Lejla Transl Vis Sci Technol Article PURPOSE: To investigate the use of imaging modalities in the volumetric measurement of the subretinal space and examine the volume of subretinal blebs created by a subretinal drug delivery device utilizing microscope-integrated optical coherence tomography (MIOCT). METHODS: An MIOCT image-based volume measurement method was developed and assessed for accuracy and reproducibility by imaging ceramic spheres of known size that were surgically implanted into ex vivo porcine eyes. This method was then used to measure subretinal blebs created in 10 porcine eyes by injection of balanced salt solution utilizing a subretinal delivery device via a suprachoroidal cannula. Bleb volumes obtained from MIOCT were compared to the intended injection volume. RESULTS: Validation of image-based volume measurements of ceramic spheres showed accuracy to ±0.029 µL (5.6%) for objects imaged over the posterior pole and ±0.025 µL (4.8%) over peripheral retina. The mean expected injection volume from extraocular tests of the suprachoroidal cannula was 66.44 µL (σ = 2.4 µL). The mean injection volume as measured by the MIOCT imaging method was 54.8 µL (σ = 12.3 µL), or 82.48% of expected injection volume. CONCLUSIONS: MIOCT can measure the volume of subretinal blebs with accuracy and precision. The novel suprachoroidal approach using a subretinal delivery device was able to deliver greater than 80% of expected injection volume into the subretinal space, as assessed by MIOCT. TRANSLATIONAL RELEVANCE: MIOCT provides a method for visualization, and analysis of images enables surgeons to quantify and evaluate the success of subretinal drug delivery via a suprachoroidal approach. The Association for Research in Vision and Ophthalmology 2021-06-17 /pmc/articles/PMC8212437/ /pubmed/34137836 http://dx.doi.org/10.1167/tvst.10.7.24 Text en Copyright 2021 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
spellingShingle Article
Sastry, Ananth
Li, Jianwei D.
Raynor, William
Viehland, Christian
Song, Zhenxi
Xu, Liangyu
Farsiu, Sina
Izatt, Joseph A.
Toth, Cynthia A.
Vajzovic, Lejla
Microscope-Integrated OCT-Guided Volumetric Measurements of Subretinal Blebs Created by a Suprachoroidal Approach
title Microscope-Integrated OCT-Guided Volumetric Measurements of Subretinal Blebs Created by a Suprachoroidal Approach
title_full Microscope-Integrated OCT-Guided Volumetric Measurements of Subretinal Blebs Created by a Suprachoroidal Approach
title_fullStr Microscope-Integrated OCT-Guided Volumetric Measurements of Subretinal Blebs Created by a Suprachoroidal Approach
title_full_unstemmed Microscope-Integrated OCT-Guided Volumetric Measurements of Subretinal Blebs Created by a Suprachoroidal Approach
title_short Microscope-Integrated OCT-Guided Volumetric Measurements of Subretinal Blebs Created by a Suprachoroidal Approach
title_sort microscope-integrated oct-guided volumetric measurements of subretinal blebs created by a suprachoroidal approach
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8212437/
https://www.ncbi.nlm.nih.gov/pubmed/34137836
http://dx.doi.org/10.1167/tvst.10.7.24
work_keys_str_mv AT sastryananth microscopeintegratedoctguidedvolumetricmeasurementsofsubretinalblebscreatedbyasuprachoroidalapproach
AT lijianweid microscopeintegratedoctguidedvolumetricmeasurementsofsubretinalblebscreatedbyasuprachoroidalapproach
AT raynorwilliam microscopeintegratedoctguidedvolumetricmeasurementsofsubretinalblebscreatedbyasuprachoroidalapproach
AT viehlandchristian microscopeintegratedoctguidedvolumetricmeasurementsofsubretinalblebscreatedbyasuprachoroidalapproach
AT songzhenxi microscopeintegratedoctguidedvolumetricmeasurementsofsubretinalblebscreatedbyasuprachoroidalapproach
AT xuliangyu microscopeintegratedoctguidedvolumetricmeasurementsofsubretinalblebscreatedbyasuprachoroidalapproach
AT farsiusina microscopeintegratedoctguidedvolumetricmeasurementsofsubretinalblebscreatedbyasuprachoroidalapproach
AT izattjosepha microscopeintegratedoctguidedvolumetricmeasurementsofsubretinalblebscreatedbyasuprachoroidalapproach
AT tothcynthiaa microscopeintegratedoctguidedvolumetricmeasurementsofsubretinalblebscreatedbyasuprachoroidalapproach
AT vajzoviclejla microscopeintegratedoctguidedvolumetricmeasurementsofsubretinalblebscreatedbyasuprachoroidalapproach