Cargando…

Preclinical Assessment of a Novel Conformable Foam-Based Left Atrial Appendage Closure Device

BACKGROUND: Left atrial appendage (LAA) occlusion has been established as an alternative to systemic anticoagulation for stroke prevention in patients with atrial fibrillation; however, limitations of current devices have slowed adoption. We present preclinical evaluations of a novel device, the Con...

Descripción completa

Detalles Bibliográficos
Autores principales: Sommer, Robert J., Lamport, Ronald, Melanson, David, Devellian, Carol, Levine, Andy, Cain, Christopher M., Kaplan, Aaron V., Gray, William A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8213491/
https://www.ncbi.nlm.nih.gov/pubmed/34222469
http://dx.doi.org/10.1155/2021/4556400
_version_ 1783709859064053760
author Sommer, Robert J.
Lamport, Ronald
Melanson, David
Devellian, Carol
Levine, Andy
Cain, Christopher M.
Kaplan, Aaron V.
Gray, William A.
author_facet Sommer, Robert J.
Lamport, Ronald
Melanson, David
Devellian, Carol
Levine, Andy
Cain, Christopher M.
Kaplan, Aaron V.
Gray, William A.
author_sort Sommer, Robert J.
collection PubMed
description BACKGROUND: Left atrial appendage (LAA) occlusion has been established as an alternative to systemic anticoagulation for stroke prevention in patients with atrial fibrillation; however, limitations of current devices have slowed adoption. We present preclinical evaluations of a novel device, the Conformal Left Atrial Appendage Seal (CLAAS). METHODS: An in vitro assessment of conformability was conducted to evaluate the two CLAAS devices (regular 27 mm and large 35 mm) and a Watchman 2.5 (27 mm). Devices were placed within silicone tubes and compressed in a vise submerged in a water bath at 37°C. Changes in device diameter and visual seal were noted. Acute (n = 1) and chronic 60-day (n = 6) canine studies with gross and histologic assessment were performed. RESULTS: Conformability bench tests demonstrated that the regular CLAAS implant was able to seal oval orifices from 20 × 30 mm to 15 × 33 mm and the large from 30 × 35 mm to 20 × 40 mm. As the CLAAS implant was compressed in the minor diameter, it increased in the major diameter, thereby filling the oval space, whereas the Watchman 2.5 showed gaps and maintained its round configuration when compressed in one direction. Seven devices were successfully implanted in the canine model with complete seal without thrombus. Histologic examination showed complete neointima covering with minimal inflammation at 60 days. CONCLUSIONS: Preclinical testing demonstrated the conformability of the CLAAS implant and its ability to seal the LAA. Clinical studies are ongoing to characterize the utility of the CLAAS implant in the treatment of patients with atrial fibrillation.
format Online
Article
Text
id pubmed-8213491
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-82134912021-07-01 Preclinical Assessment of a Novel Conformable Foam-Based Left Atrial Appendage Closure Device Sommer, Robert J. Lamport, Ronald Melanson, David Devellian, Carol Levine, Andy Cain, Christopher M. Kaplan, Aaron V. Gray, William A. Biomed Res Int Research Article BACKGROUND: Left atrial appendage (LAA) occlusion has been established as an alternative to systemic anticoagulation for stroke prevention in patients with atrial fibrillation; however, limitations of current devices have slowed adoption. We present preclinical evaluations of a novel device, the Conformal Left Atrial Appendage Seal (CLAAS). METHODS: An in vitro assessment of conformability was conducted to evaluate the two CLAAS devices (regular 27 mm and large 35 mm) and a Watchman 2.5 (27 mm). Devices were placed within silicone tubes and compressed in a vise submerged in a water bath at 37°C. Changes in device diameter and visual seal were noted. Acute (n = 1) and chronic 60-day (n = 6) canine studies with gross and histologic assessment were performed. RESULTS: Conformability bench tests demonstrated that the regular CLAAS implant was able to seal oval orifices from 20 × 30 mm to 15 × 33 mm and the large from 30 × 35 mm to 20 × 40 mm. As the CLAAS implant was compressed in the minor diameter, it increased in the major diameter, thereby filling the oval space, whereas the Watchman 2.5 showed gaps and maintained its round configuration when compressed in one direction. Seven devices were successfully implanted in the canine model with complete seal without thrombus. Histologic examination showed complete neointima covering with minimal inflammation at 60 days. CONCLUSIONS: Preclinical testing demonstrated the conformability of the CLAAS implant and its ability to seal the LAA. Clinical studies are ongoing to characterize the utility of the CLAAS implant in the treatment of patients with atrial fibrillation. Hindawi 2021-06-10 /pmc/articles/PMC8213491/ /pubmed/34222469 http://dx.doi.org/10.1155/2021/4556400 Text en Copyright © 2021 Robert J. Sommer et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Sommer, Robert J.
Lamport, Ronald
Melanson, David
Devellian, Carol
Levine, Andy
Cain, Christopher M.
Kaplan, Aaron V.
Gray, William A.
Preclinical Assessment of a Novel Conformable Foam-Based Left Atrial Appendage Closure Device
title Preclinical Assessment of a Novel Conformable Foam-Based Left Atrial Appendage Closure Device
title_full Preclinical Assessment of a Novel Conformable Foam-Based Left Atrial Appendage Closure Device
title_fullStr Preclinical Assessment of a Novel Conformable Foam-Based Left Atrial Appendage Closure Device
title_full_unstemmed Preclinical Assessment of a Novel Conformable Foam-Based Left Atrial Appendage Closure Device
title_short Preclinical Assessment of a Novel Conformable Foam-Based Left Atrial Appendage Closure Device
title_sort preclinical assessment of a novel conformable foam-based left atrial appendage closure device
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8213491/
https://www.ncbi.nlm.nih.gov/pubmed/34222469
http://dx.doi.org/10.1155/2021/4556400
work_keys_str_mv AT sommerrobertj preclinicalassessmentofanovelconformablefoambasedleftatrialappendageclosuredevice
AT lamportronald preclinicalassessmentofanovelconformablefoambasedleftatrialappendageclosuredevice
AT melansondavid preclinicalassessmentofanovelconformablefoambasedleftatrialappendageclosuredevice
AT develliancarol preclinicalassessmentofanovelconformablefoambasedleftatrialappendageclosuredevice
AT levineandy preclinicalassessmentofanovelconformablefoambasedleftatrialappendageclosuredevice
AT cainchristopherm preclinicalassessmentofanovelconformablefoambasedleftatrialappendageclosuredevice
AT kaplanaaronv preclinicalassessmentofanovelconformablefoambasedleftatrialappendageclosuredevice
AT graywilliama preclinicalassessmentofanovelconformablefoambasedleftatrialappendageclosuredevice