Cargando…

Long-Term Suture Breakage After Scleral Fixation of a Modified Capsular Tension Ring with Polypropylene 10-0 Suture

AIM: To investigate the long-term risk of suture breakage after implantation of a modified capsular tension ring (MCTR) fixated to the sclera with polypropylene 10–0 suture. METHODS: Retrospective case series of operations for subluxated phakic lenses in 2007–2015 with implantation of an MCTR secure...

Descripción completa

Detalles Bibliográficos
Autores principales: Kristianslund, Olav, Sandvik, Gunhild F, Drolsum, Liv
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8214109/
https://www.ncbi.nlm.nih.gov/pubmed/34163130
http://dx.doi.org/10.2147/OPTH.S310648
_version_ 1783709992952528896
author Kristianslund, Olav
Sandvik, Gunhild F
Drolsum, Liv
author_facet Kristianslund, Olav
Sandvik, Gunhild F
Drolsum, Liv
author_sort Kristianslund, Olav
collection PubMed
description AIM: To investigate the long-term risk of suture breakage after implantation of a modified capsular tension ring (MCTR) fixated to the sclera with polypropylene 10–0 suture. METHODS: Retrospective case series of operations for subluxated phakic lenses in 2007–2015 with implantation of an MCTR secured with a 10–0 polypropylene suture as part of an intraocular lens (IOL)-capsular bag complex. RESULTS: We identified 132 eyes (92 patients) operated on with an MCTR. Of these eyes, 26 (20%) had suture breakage requiring re-operation, while another eight eyes (6%) had suture breakage that did not require surgery. The re-operations occurred after a mean 4.8±3.3 years. Suture breakage occurred in patients with a mean age of 34.0±23.3, as compared to 43.2±26.0 years for patients who did not experience this complication (p=0.36). In patients aged 40 years or younger at the time of surgery, 47% experienced suture breakage in one or both eyes, as compared to 19% in the age group 41–69 years and 13% in the age group 70 years and older (p=0.004). Of the 132 eyes that were operated on, we registered one case (0.8%) of possible suture-related late endophthalmitis. CONCLUSION: The long-term risk of suture breakage was quite high after scleral fixation of the MCTR in this patient cohort, and it seems as the risk is increased with young age.
format Online
Article
Text
id pubmed-8214109
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-82141092021-06-22 Long-Term Suture Breakage After Scleral Fixation of a Modified Capsular Tension Ring with Polypropylene 10-0 Suture Kristianslund, Olav Sandvik, Gunhild F Drolsum, Liv Clin Ophthalmol Original Research AIM: To investigate the long-term risk of suture breakage after implantation of a modified capsular tension ring (MCTR) fixated to the sclera with polypropylene 10–0 suture. METHODS: Retrospective case series of operations for subluxated phakic lenses in 2007–2015 with implantation of an MCTR secured with a 10–0 polypropylene suture as part of an intraocular lens (IOL)-capsular bag complex. RESULTS: We identified 132 eyes (92 patients) operated on with an MCTR. Of these eyes, 26 (20%) had suture breakage requiring re-operation, while another eight eyes (6%) had suture breakage that did not require surgery. The re-operations occurred after a mean 4.8±3.3 years. Suture breakage occurred in patients with a mean age of 34.0±23.3, as compared to 43.2±26.0 years for patients who did not experience this complication (p=0.36). In patients aged 40 years or younger at the time of surgery, 47% experienced suture breakage in one or both eyes, as compared to 19% in the age group 41–69 years and 13% in the age group 70 years and older (p=0.004). Of the 132 eyes that were operated on, we registered one case (0.8%) of possible suture-related late endophthalmitis. CONCLUSION: The long-term risk of suture breakage was quite high after scleral fixation of the MCTR in this patient cohort, and it seems as the risk is increased with young age. Dove 2021-06-14 /pmc/articles/PMC8214109/ /pubmed/34163130 http://dx.doi.org/10.2147/OPTH.S310648 Text en © 2021 Kristianslund et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
Kristianslund, Olav
Sandvik, Gunhild F
Drolsum, Liv
Long-Term Suture Breakage After Scleral Fixation of a Modified Capsular Tension Ring with Polypropylene 10-0 Suture
title Long-Term Suture Breakage After Scleral Fixation of a Modified Capsular Tension Ring with Polypropylene 10-0 Suture
title_full Long-Term Suture Breakage After Scleral Fixation of a Modified Capsular Tension Ring with Polypropylene 10-0 Suture
title_fullStr Long-Term Suture Breakage After Scleral Fixation of a Modified Capsular Tension Ring with Polypropylene 10-0 Suture
title_full_unstemmed Long-Term Suture Breakage After Scleral Fixation of a Modified Capsular Tension Ring with Polypropylene 10-0 Suture
title_short Long-Term Suture Breakage After Scleral Fixation of a Modified Capsular Tension Ring with Polypropylene 10-0 Suture
title_sort long-term suture breakage after scleral fixation of a modified capsular tension ring with polypropylene 10-0 suture
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8214109/
https://www.ncbi.nlm.nih.gov/pubmed/34163130
http://dx.doi.org/10.2147/OPTH.S310648
work_keys_str_mv AT kristianslundolav longtermsuturebreakageafterscleralfixationofamodifiedcapsulartensionringwithpolypropylene100suture
AT sandvikgunhildf longtermsuturebreakageafterscleralfixationofamodifiedcapsulartensionringwithpolypropylene100suture
AT drolsumliv longtermsuturebreakageafterscleralfixationofamodifiedcapsulartensionringwithpolypropylene100suture