Cargando…
Long-Term Suture Breakage After Scleral Fixation of a Modified Capsular Tension Ring with Polypropylene 10-0 Suture
AIM: To investigate the long-term risk of suture breakage after implantation of a modified capsular tension ring (MCTR) fixated to the sclera with polypropylene 10–0 suture. METHODS: Retrospective case series of operations for subluxated phakic lenses in 2007–2015 with implantation of an MCTR secure...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8214109/ https://www.ncbi.nlm.nih.gov/pubmed/34163130 http://dx.doi.org/10.2147/OPTH.S310648 |
_version_ | 1783709992952528896 |
---|---|
author | Kristianslund, Olav Sandvik, Gunhild F Drolsum, Liv |
author_facet | Kristianslund, Olav Sandvik, Gunhild F Drolsum, Liv |
author_sort | Kristianslund, Olav |
collection | PubMed |
description | AIM: To investigate the long-term risk of suture breakage after implantation of a modified capsular tension ring (MCTR) fixated to the sclera with polypropylene 10–0 suture. METHODS: Retrospective case series of operations for subluxated phakic lenses in 2007–2015 with implantation of an MCTR secured with a 10–0 polypropylene suture as part of an intraocular lens (IOL)-capsular bag complex. RESULTS: We identified 132 eyes (92 patients) operated on with an MCTR. Of these eyes, 26 (20%) had suture breakage requiring re-operation, while another eight eyes (6%) had suture breakage that did not require surgery. The re-operations occurred after a mean 4.8±3.3 years. Suture breakage occurred in patients with a mean age of 34.0±23.3, as compared to 43.2±26.0 years for patients who did not experience this complication (p=0.36). In patients aged 40 years or younger at the time of surgery, 47% experienced suture breakage in one or both eyes, as compared to 19% in the age group 41–69 years and 13% in the age group 70 years and older (p=0.004). Of the 132 eyes that were operated on, we registered one case (0.8%) of possible suture-related late endophthalmitis. CONCLUSION: The long-term risk of suture breakage was quite high after scleral fixation of the MCTR in this patient cohort, and it seems as the risk is increased with young age. |
format | Online Article Text |
id | pubmed-8214109 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Dove |
record_format | MEDLINE/PubMed |
spelling | pubmed-82141092021-06-22 Long-Term Suture Breakage After Scleral Fixation of a Modified Capsular Tension Ring with Polypropylene 10-0 Suture Kristianslund, Olav Sandvik, Gunhild F Drolsum, Liv Clin Ophthalmol Original Research AIM: To investigate the long-term risk of suture breakage after implantation of a modified capsular tension ring (MCTR) fixated to the sclera with polypropylene 10–0 suture. METHODS: Retrospective case series of operations for subluxated phakic lenses in 2007–2015 with implantation of an MCTR secured with a 10–0 polypropylene suture as part of an intraocular lens (IOL)-capsular bag complex. RESULTS: We identified 132 eyes (92 patients) operated on with an MCTR. Of these eyes, 26 (20%) had suture breakage requiring re-operation, while another eight eyes (6%) had suture breakage that did not require surgery. The re-operations occurred after a mean 4.8±3.3 years. Suture breakage occurred in patients with a mean age of 34.0±23.3, as compared to 43.2±26.0 years for patients who did not experience this complication (p=0.36). In patients aged 40 years or younger at the time of surgery, 47% experienced suture breakage in one or both eyes, as compared to 19% in the age group 41–69 years and 13% in the age group 70 years and older (p=0.004). Of the 132 eyes that were operated on, we registered one case (0.8%) of possible suture-related late endophthalmitis. CONCLUSION: The long-term risk of suture breakage was quite high after scleral fixation of the MCTR in this patient cohort, and it seems as the risk is increased with young age. Dove 2021-06-14 /pmc/articles/PMC8214109/ /pubmed/34163130 http://dx.doi.org/10.2147/OPTH.S310648 Text en © 2021 Kristianslund et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php). |
spellingShingle | Original Research Kristianslund, Olav Sandvik, Gunhild F Drolsum, Liv Long-Term Suture Breakage After Scleral Fixation of a Modified Capsular Tension Ring with Polypropylene 10-0 Suture |
title | Long-Term Suture Breakage After Scleral Fixation of a Modified Capsular Tension Ring with Polypropylene 10-0 Suture |
title_full | Long-Term Suture Breakage After Scleral Fixation of a Modified Capsular Tension Ring with Polypropylene 10-0 Suture |
title_fullStr | Long-Term Suture Breakage After Scleral Fixation of a Modified Capsular Tension Ring with Polypropylene 10-0 Suture |
title_full_unstemmed | Long-Term Suture Breakage After Scleral Fixation of a Modified Capsular Tension Ring with Polypropylene 10-0 Suture |
title_short | Long-Term Suture Breakage After Scleral Fixation of a Modified Capsular Tension Ring with Polypropylene 10-0 Suture |
title_sort | long-term suture breakage after scleral fixation of a modified capsular tension ring with polypropylene 10-0 suture |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8214109/ https://www.ncbi.nlm.nih.gov/pubmed/34163130 http://dx.doi.org/10.2147/OPTH.S310648 |
work_keys_str_mv | AT kristianslundolav longtermsuturebreakageafterscleralfixationofamodifiedcapsulartensionringwithpolypropylene100suture AT sandvikgunhildf longtermsuturebreakageafterscleralfixationofamodifiedcapsulartensionringwithpolypropylene100suture AT drolsumliv longtermsuturebreakageafterscleralfixationofamodifiedcapsulartensionringwithpolypropylene100suture |