Cargando…

Comparison of diagnostic performance in on-site based CT-derived fractional flow reserve measurements

BACKGROUND: Computed tomography fractional flow reserve (CT-FFR), which can be acquired on-site workstation using fluid structure interaction during the multiple optimal diastolic phase, has an incremental diagnostic value over conventional coronary computed tomography angiography (CCTA). However, t...

Descripción completa

Detalles Bibliográficos
Autores principales: Nozaki, Yui O., Fujimoto, Shinichiro, Aoshima, Chihiro, Kamo, Yuki, Kawaguchi, Yuko O., Takamura, Kazuhisa, Kudo, Ayako, Takahashi, Daigo, Hiki, Makoto, Kato, Yoshiteru, Okai, Iwao, Dohi, Tomotaka, Okazaki, Shinya, Tomizawa, Nobuo, Kumamaru, Kanako K., Aoki, Shigeki, Minamino, Tohru
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8215214/
https://www.ncbi.nlm.nih.gov/pubmed/34189251
http://dx.doi.org/10.1016/j.ijcha.2021.100815
_version_ 1783710202998030336
author Nozaki, Yui O.
Fujimoto, Shinichiro
Aoshima, Chihiro
Kamo, Yuki
Kawaguchi, Yuko O.
Takamura, Kazuhisa
Kudo, Ayako
Takahashi, Daigo
Hiki, Makoto
Kato, Yoshiteru
Okai, Iwao
Dohi, Tomotaka
Okazaki, Shinya
Tomizawa, Nobuo
Kumamaru, Kanako K.
Aoki, Shigeki
Minamino, Tohru
author_facet Nozaki, Yui O.
Fujimoto, Shinichiro
Aoshima, Chihiro
Kamo, Yuki
Kawaguchi, Yuko O.
Takamura, Kazuhisa
Kudo, Ayako
Takahashi, Daigo
Hiki, Makoto
Kato, Yoshiteru
Okai, Iwao
Dohi, Tomotaka
Okazaki, Shinya
Tomizawa, Nobuo
Kumamaru, Kanako K.
Aoki, Shigeki
Minamino, Tohru
author_sort Nozaki, Yui O.
collection PubMed
description BACKGROUND: Computed tomography fractional flow reserve (CT-FFR), which can be acquired on-site workstation using fluid structure interaction during the multiple optimal diastolic phase, has an incremental diagnostic value over conventional coronary computed tomography angiography (CCTA). However, the appropriate location for CT-FFR measurement remains to be clarified. METHOD: A total of 115 consecutive patients with 149 vessels who underwent CCTA showing 30–90% stenosis with invasive FFR within 90 days were retrospectively analyzed. CT-FFR values were measured at three points: 1 and 2 cm distal to the target lesion (CT-FFR(1cm, 2cm)) and the vessel terminus (CT-FFR(lowest)). The diagnostic accuracies of CT-FFR ≤ 0.80 for detecting hemodynamically significant stenosis, defined as invasive FFR ≤ 0.80, were compered. RESULT: Fifty-five vessels (36.9%) had invasive FFR ≤ 0.80. The accuracy and AUC for CT-FFR(1cm) and (2cm) were comparable, while the AUC for CT-FFR(lowest) was significantly lower than CT-FFR(1cm) and (2cm). (lowest/1cm, 2 cm = 0.68 (95 %CI 0.63–0.73) vs 0.79 (0.72–0.86, p = 0.006), 0.80 (0.73–0.87, p = 0.002)) The sensitivity and negative predictive value of CT-FFR(lowest) were 100%. The reclassification rates from positive CT-FFR(lowest) to negative CT-FFR(1cm) and (2cm) were 55.7% and 54.2%, respectively. CONCLUSION: The diagnostic performance of CT-FFR was comparable when measured at 1-to-2 cm distal to the target lesion, but significantly higher than CT-FFR(lowest). The lesion-specific CT-FFR could reclassify false positive cases in patients with positive CT-FFR(lowest), while all patients with negative CT-FFR(lowest) were diagnosed as negative by invasive FFR.
format Online
Article
Text
id pubmed-8215214
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-82152142021-06-28 Comparison of diagnostic performance in on-site based CT-derived fractional flow reserve measurements Nozaki, Yui O. Fujimoto, Shinichiro Aoshima, Chihiro Kamo, Yuki Kawaguchi, Yuko O. Takamura, Kazuhisa Kudo, Ayako Takahashi, Daigo Hiki, Makoto Kato, Yoshiteru Okai, Iwao Dohi, Tomotaka Okazaki, Shinya Tomizawa, Nobuo Kumamaru, Kanako K. Aoki, Shigeki Minamino, Tohru Int J Cardiol Heart Vasc Original Paper BACKGROUND: Computed tomography fractional flow reserve (CT-FFR), which can be acquired on-site workstation using fluid structure interaction during the multiple optimal diastolic phase, has an incremental diagnostic value over conventional coronary computed tomography angiography (CCTA). However, the appropriate location for CT-FFR measurement remains to be clarified. METHOD: A total of 115 consecutive patients with 149 vessels who underwent CCTA showing 30–90% stenosis with invasive FFR within 90 days were retrospectively analyzed. CT-FFR values were measured at three points: 1 and 2 cm distal to the target lesion (CT-FFR(1cm, 2cm)) and the vessel terminus (CT-FFR(lowest)). The diagnostic accuracies of CT-FFR ≤ 0.80 for detecting hemodynamically significant stenosis, defined as invasive FFR ≤ 0.80, were compered. RESULT: Fifty-five vessels (36.9%) had invasive FFR ≤ 0.80. The accuracy and AUC for CT-FFR(1cm) and (2cm) were comparable, while the AUC for CT-FFR(lowest) was significantly lower than CT-FFR(1cm) and (2cm). (lowest/1cm, 2 cm = 0.68 (95 %CI 0.63–0.73) vs 0.79 (0.72–0.86, p = 0.006), 0.80 (0.73–0.87, p = 0.002)) The sensitivity and negative predictive value of CT-FFR(lowest) were 100%. The reclassification rates from positive CT-FFR(lowest) to negative CT-FFR(1cm) and (2cm) were 55.7% and 54.2%, respectively. CONCLUSION: The diagnostic performance of CT-FFR was comparable when measured at 1-to-2 cm distal to the target lesion, but significantly higher than CT-FFR(lowest). The lesion-specific CT-FFR could reclassify false positive cases in patients with positive CT-FFR(lowest), while all patients with negative CT-FFR(lowest) were diagnosed as negative by invasive FFR. Elsevier 2021-06-11 /pmc/articles/PMC8215214/ /pubmed/34189251 http://dx.doi.org/10.1016/j.ijcha.2021.100815 Text en © 2021 The Authors https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Original Paper
Nozaki, Yui O.
Fujimoto, Shinichiro
Aoshima, Chihiro
Kamo, Yuki
Kawaguchi, Yuko O.
Takamura, Kazuhisa
Kudo, Ayako
Takahashi, Daigo
Hiki, Makoto
Kato, Yoshiteru
Okai, Iwao
Dohi, Tomotaka
Okazaki, Shinya
Tomizawa, Nobuo
Kumamaru, Kanako K.
Aoki, Shigeki
Minamino, Tohru
Comparison of diagnostic performance in on-site based CT-derived fractional flow reserve measurements
title Comparison of diagnostic performance in on-site based CT-derived fractional flow reserve measurements
title_full Comparison of diagnostic performance in on-site based CT-derived fractional flow reserve measurements
title_fullStr Comparison of diagnostic performance in on-site based CT-derived fractional flow reserve measurements
title_full_unstemmed Comparison of diagnostic performance in on-site based CT-derived fractional flow reserve measurements
title_short Comparison of diagnostic performance in on-site based CT-derived fractional flow reserve measurements
title_sort comparison of diagnostic performance in on-site based ct-derived fractional flow reserve measurements
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8215214/
https://www.ncbi.nlm.nih.gov/pubmed/34189251
http://dx.doi.org/10.1016/j.ijcha.2021.100815
work_keys_str_mv AT nozakiyuio comparisonofdiagnosticperformanceinonsitebasedctderivedfractionalflowreservemeasurements
AT fujimotoshinichiro comparisonofdiagnosticperformanceinonsitebasedctderivedfractionalflowreservemeasurements
AT aoshimachihiro comparisonofdiagnosticperformanceinonsitebasedctderivedfractionalflowreservemeasurements
AT kamoyuki comparisonofdiagnosticperformanceinonsitebasedctderivedfractionalflowreservemeasurements
AT kawaguchiyukoo comparisonofdiagnosticperformanceinonsitebasedctderivedfractionalflowreservemeasurements
AT takamurakazuhisa comparisonofdiagnosticperformanceinonsitebasedctderivedfractionalflowreservemeasurements
AT kudoayako comparisonofdiagnosticperformanceinonsitebasedctderivedfractionalflowreservemeasurements
AT takahashidaigo comparisonofdiagnosticperformanceinonsitebasedctderivedfractionalflowreservemeasurements
AT hikimakoto comparisonofdiagnosticperformanceinonsitebasedctderivedfractionalflowreservemeasurements
AT katoyoshiteru comparisonofdiagnosticperformanceinonsitebasedctderivedfractionalflowreservemeasurements
AT okaiiwao comparisonofdiagnosticperformanceinonsitebasedctderivedfractionalflowreservemeasurements
AT dohitomotaka comparisonofdiagnosticperformanceinonsitebasedctderivedfractionalflowreservemeasurements
AT okazakishinya comparisonofdiagnosticperformanceinonsitebasedctderivedfractionalflowreservemeasurements
AT tomizawanobuo comparisonofdiagnosticperformanceinonsitebasedctderivedfractionalflowreservemeasurements
AT kumamarukanakok comparisonofdiagnosticperformanceinonsitebasedctderivedfractionalflowreservemeasurements
AT aokishigeki comparisonofdiagnosticperformanceinonsitebasedctderivedfractionalflowreservemeasurements
AT minaminotohru comparisonofdiagnosticperformanceinonsitebasedctderivedfractionalflowreservemeasurements