Cargando…

Polyethylene glycol-based hydrogel rectal spacers for prostate brachytherapy: a systematic review with a focus on technique

INTRODUCTION: Radiation dose to the rectum in prostate brachytherapy (PBT) can be reduced by the use of polyethylene glycol (PEG) hydrogel spacers. This reduces the rate of rectal toxicity and allows dose escalation to the prostate. Our objectives were to provide an overview of technique for injecti...

Descripción completa

Detalles Bibliográficos
Autores principales: Vaggers, S., Rai, B. P., Chedgy, E. C. P., de la Taille, A., Somani, B. K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8217059/
https://www.ncbi.nlm.nih.gov/pubmed/32840655
http://dx.doi.org/10.1007/s00345-020-03414-6
_version_ 1783710550646063104
author Vaggers, S.
Rai, B. P.
Chedgy, E. C. P.
de la Taille, A.
Somani, B. K.
author_facet Vaggers, S.
Rai, B. P.
Chedgy, E. C. P.
de la Taille, A.
Somani, B. K.
author_sort Vaggers, S.
collection PubMed
description INTRODUCTION: Radiation dose to the rectum in prostate brachytherapy (PBT) can be reduced by the use of polyethylene glycol (PEG) hydrogel spacers. This reduces the rate of rectal toxicity and allows dose escalation to the prostate. Our objectives were to provide an overview of technique for injection of a PEG hydrogel spacer, reduction in rectal dosimetry, gastrointestinal toxicity and potential complications. METHODS: We systematically reviewed the role of PEG hydrogel spacers in PBT using the Cochrane and PRISMA methodology for all English-language articles from January 2013 to December 2019. Data was extracted for type of radiotherapy, number of patients, type of PEG-hydrogel used, mean prostate-rectum separation, rectal dosimetry, acute and late GI toxicity, procedure-related complications and the technique used for hydrogel insertion. RESULTS: Nine studies (671 patients and 537 controls) met our inclusion criteria. Of these 4 used DuraSeal(®) and 5 used SpaceOAR(®). The rectal spacing achieved varied between 7.7-16 mm. Failure of hydrogel insertion was seen only in 12 patients, mostly related to failure of hydrodissection in patients undergoing salvage PBT. Where reported, the rectal D2 cc was reduced by between 21.6 and 52.6% and the median rectal V75% cc was reduced by between 91.8–100%. Acute GI complications were mostly limited to grade 1 or 2 toxicity (n = 153, 33.7%) with low levels of grade 3 or 4 toxicity (n = 1, 0.22%). Procedure-related complications were limited to tenesmus (0.14%), rectal discomfort (1.19%), and bacterial prostatitis (0.44%). CONCLUSIONS: PEG hydrogel spacers are safe to insert. Gel insertion is easy, fast and has a low rate of failure. These studies convincingly demonstrate a significant reduction in rectal dosimetry. Although the results of spacers in reducing rectal toxicity is promising, these need to be confirmed in prospective randomised trial. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00345-020-03414-6) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-8217059
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-82170592021-07-09 Polyethylene glycol-based hydrogel rectal spacers for prostate brachytherapy: a systematic review with a focus on technique Vaggers, S. Rai, B. P. Chedgy, E. C. P. de la Taille, A. Somani, B. K. World J Urol Original Article INTRODUCTION: Radiation dose to the rectum in prostate brachytherapy (PBT) can be reduced by the use of polyethylene glycol (PEG) hydrogel spacers. This reduces the rate of rectal toxicity and allows dose escalation to the prostate. Our objectives were to provide an overview of technique for injection of a PEG hydrogel spacer, reduction in rectal dosimetry, gastrointestinal toxicity and potential complications. METHODS: We systematically reviewed the role of PEG hydrogel spacers in PBT using the Cochrane and PRISMA methodology for all English-language articles from January 2013 to December 2019. Data was extracted for type of radiotherapy, number of patients, type of PEG-hydrogel used, mean prostate-rectum separation, rectal dosimetry, acute and late GI toxicity, procedure-related complications and the technique used for hydrogel insertion. RESULTS: Nine studies (671 patients and 537 controls) met our inclusion criteria. Of these 4 used DuraSeal(®) and 5 used SpaceOAR(®). The rectal spacing achieved varied between 7.7-16 mm. Failure of hydrogel insertion was seen only in 12 patients, mostly related to failure of hydrodissection in patients undergoing salvage PBT. Where reported, the rectal D2 cc was reduced by between 21.6 and 52.6% and the median rectal V75% cc was reduced by between 91.8–100%. Acute GI complications were mostly limited to grade 1 or 2 toxicity (n = 153, 33.7%) with low levels of grade 3 or 4 toxicity (n = 1, 0.22%). Procedure-related complications were limited to tenesmus (0.14%), rectal discomfort (1.19%), and bacterial prostatitis (0.44%). CONCLUSIONS: PEG hydrogel spacers are safe to insert. Gel insertion is easy, fast and has a low rate of failure. These studies convincingly demonstrate a significant reduction in rectal dosimetry. Although the results of spacers in reducing rectal toxicity is promising, these need to be confirmed in prospective randomised trial. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00345-020-03414-6) contains supplementary material, which is available to authorized users. Springer Berlin Heidelberg 2020-08-25 2021 /pmc/articles/PMC8217059/ /pubmed/32840655 http://dx.doi.org/10.1007/s00345-020-03414-6 Text en © The Author(s) 2020 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Vaggers, S.
Rai, B. P.
Chedgy, E. C. P.
de la Taille, A.
Somani, B. K.
Polyethylene glycol-based hydrogel rectal spacers for prostate brachytherapy: a systematic review with a focus on technique
title Polyethylene glycol-based hydrogel rectal spacers for prostate brachytherapy: a systematic review with a focus on technique
title_full Polyethylene glycol-based hydrogel rectal spacers for prostate brachytherapy: a systematic review with a focus on technique
title_fullStr Polyethylene glycol-based hydrogel rectal spacers for prostate brachytherapy: a systematic review with a focus on technique
title_full_unstemmed Polyethylene glycol-based hydrogel rectal spacers for prostate brachytherapy: a systematic review with a focus on technique
title_short Polyethylene glycol-based hydrogel rectal spacers for prostate brachytherapy: a systematic review with a focus on technique
title_sort polyethylene glycol-based hydrogel rectal spacers for prostate brachytherapy: a systematic review with a focus on technique
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8217059/
https://www.ncbi.nlm.nih.gov/pubmed/32840655
http://dx.doi.org/10.1007/s00345-020-03414-6
work_keys_str_mv AT vaggerss polyethyleneglycolbasedhydrogelrectalspacersforprostatebrachytherapyasystematicreviewwithafocusontechnique
AT raibp polyethyleneglycolbasedhydrogelrectalspacersforprostatebrachytherapyasystematicreviewwithafocusontechnique
AT chedgyecp polyethyleneglycolbasedhydrogelrectalspacersforprostatebrachytherapyasystematicreviewwithafocusontechnique
AT delataillea polyethyleneglycolbasedhydrogelrectalspacersforprostatebrachytherapyasystematicreviewwithafocusontechnique
AT somanibk polyethyleneglycolbasedhydrogelrectalspacersforprostatebrachytherapyasystematicreviewwithafocusontechnique