Reproducibility and diagnostic performance of the vascular index of superb microvascular imaging in real-time breast ultrasonography for evaluating breast masses

PURPOSE: This study aimed to evaluate the reproducibility and diagnostic performance of a quantitative parameter of superb microvascular imaging (SMI) in real-time breast ultrasonography (US) for differentiating benign from malignant breast masses. METHODS: Eighty-seven breast masses in 75 patients...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Eun Ji, Chang, Yun-Woo, Oh, Eunsun, Hwang, Jiyoung, Kim, Hyun-joo, Hong, Seong Sook
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Ultrasound in Medicine 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8217793/
https://www.ncbi.nlm.nih.gov/pubmed/33455154
http://dx.doi.org/10.14366/usg.20153
_version_ 1783710662951698432
author Lee, Eun Ji
Chang, Yun-Woo
Oh, Eunsun
Hwang, Jiyoung
Kim, Hyun-joo
Hong, Seong Sook
author_facet Lee, Eun Ji
Chang, Yun-Woo
Oh, Eunsun
Hwang, Jiyoung
Kim, Hyun-joo
Hong, Seong Sook
author_sort Lee, Eun Ji
collection PubMed
description PURPOSE: This study aimed to evaluate the reproducibility and diagnostic performance of a quantitative parameter of superb microvascular imaging (SMI) in real-time breast ultrasonography (US) for differentiating benign from malignant breast masses. METHODS: Eighty-seven breast masses in 75 patients who underwent both B-mode US and SMI before US-guided core needle biopsy were included in this study. Two radiologists performed B-mode US and measured the vascular index (VI) of SMI respectively for each lesion in real time. Intraobserver and interobserver agreements were analyzed for the VI of SMI. The diagnostic performance of B-mode US using the Breast Imaging Reporting and Database System lexicon and combined use with the VI of SMI was evaluated compared to pathology. RESULTS: The median VI of malignant masses (n=32) was significantly higher than that of benign masses (n=55) (7.6% and 2.6%, respectively; P<0.001). The intraobserver agreement for VI was excellent regardless of the pathology, size, or depth of the lesion. The interobserver agreement for VI was excellent regardless of the presence of a measurement interval. The interobserver agreement for the final diagnostic decision was improved by combining B-mode US and VI (κ=0.883) in comparison with B-mode US only (κ=0.617). Adding VI led to significant improvements in the specificity (87.2% vs. 52.7%, 83.6% vs. 49.0%), accuracy (89.7% vs. 69.3%, 84.0% vs. 65.9%) and positive predictive value (81.5% vs. 55.1%, 75.6% vs. 52.6%) of B-mode US for both observers compared with B-mode US alone (all, P=0.001). CONCLUSION: The VI of SMI for real-time breast US is highly reproducible and leads to improved diagnostic performance for differentiating between benign and malignant breast lesions in combination with B-mode US.
format Online
Article
Text
id pubmed-8217793
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Korean Society of Ultrasound in Medicine
record_format MEDLINE/PubMed
spelling pubmed-82177932021-07-03 Reproducibility and diagnostic performance of the vascular index of superb microvascular imaging in real-time breast ultrasonography for evaluating breast masses Lee, Eun Ji Chang, Yun-Woo Oh, Eunsun Hwang, Jiyoung Kim, Hyun-joo Hong, Seong Sook Ultrasonography Original Article PURPOSE: This study aimed to evaluate the reproducibility and diagnostic performance of a quantitative parameter of superb microvascular imaging (SMI) in real-time breast ultrasonography (US) for differentiating benign from malignant breast masses. METHODS: Eighty-seven breast masses in 75 patients who underwent both B-mode US and SMI before US-guided core needle biopsy were included in this study. Two radiologists performed B-mode US and measured the vascular index (VI) of SMI respectively for each lesion in real time. Intraobserver and interobserver agreements were analyzed for the VI of SMI. The diagnostic performance of B-mode US using the Breast Imaging Reporting and Database System lexicon and combined use with the VI of SMI was evaluated compared to pathology. RESULTS: The median VI of malignant masses (n=32) was significantly higher than that of benign masses (n=55) (7.6% and 2.6%, respectively; P<0.001). The intraobserver agreement for VI was excellent regardless of the pathology, size, or depth of the lesion. The interobserver agreement for VI was excellent regardless of the presence of a measurement interval. The interobserver agreement for the final diagnostic decision was improved by combining B-mode US and VI (κ=0.883) in comparison with B-mode US only (κ=0.617). Adding VI led to significant improvements in the specificity (87.2% vs. 52.7%, 83.6% vs. 49.0%), accuracy (89.7% vs. 69.3%, 84.0% vs. 65.9%) and positive predictive value (81.5% vs. 55.1%, 75.6% vs. 52.6%) of B-mode US for both observers compared with B-mode US alone (all, P=0.001). CONCLUSION: The VI of SMI for real-time breast US is highly reproducible and leads to improved diagnostic performance for differentiating between benign and malignant breast lesions in combination with B-mode US. Korean Society of Ultrasound in Medicine 2021-07 2020-11-27 /pmc/articles/PMC8217793/ /pubmed/33455154 http://dx.doi.org/10.14366/usg.20153 Text en Copyright © 2021 Korean Society of Ultrasound in Medicine (KSUM) https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Lee, Eun Ji
Chang, Yun-Woo
Oh, Eunsun
Hwang, Jiyoung
Kim, Hyun-joo
Hong, Seong Sook
Reproducibility and diagnostic performance of the vascular index of superb microvascular imaging in real-time breast ultrasonography for evaluating breast masses
title Reproducibility and diagnostic performance of the vascular index of superb microvascular imaging in real-time breast ultrasonography for evaluating breast masses
title_full Reproducibility and diagnostic performance of the vascular index of superb microvascular imaging in real-time breast ultrasonography for evaluating breast masses
title_fullStr Reproducibility and diagnostic performance of the vascular index of superb microvascular imaging in real-time breast ultrasonography for evaluating breast masses
title_full_unstemmed Reproducibility and diagnostic performance of the vascular index of superb microvascular imaging in real-time breast ultrasonography for evaluating breast masses
title_short Reproducibility and diagnostic performance of the vascular index of superb microvascular imaging in real-time breast ultrasonography for evaluating breast masses
title_sort reproducibility and diagnostic performance of the vascular index of superb microvascular imaging in real-time breast ultrasonography for evaluating breast masses
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8217793/
https://www.ncbi.nlm.nih.gov/pubmed/33455154
http://dx.doi.org/10.14366/usg.20153
work_keys_str_mv AT leeeunji reproducibilityanddiagnosticperformanceofthevascularindexofsuperbmicrovascularimaginginrealtimebreastultrasonographyforevaluatingbreastmasses
AT changyunwoo reproducibilityanddiagnosticperformanceofthevascularindexofsuperbmicrovascularimaginginrealtimebreastultrasonographyforevaluatingbreastmasses
AT oheunsun reproducibilityanddiagnosticperformanceofthevascularindexofsuperbmicrovascularimaginginrealtimebreastultrasonographyforevaluatingbreastmasses
AT hwangjiyoung reproducibilityanddiagnosticperformanceofthevascularindexofsuperbmicrovascularimaginginrealtimebreastultrasonographyforevaluatingbreastmasses
AT kimhyunjoo reproducibilityanddiagnosticperformanceofthevascularindexofsuperbmicrovascularimaginginrealtimebreastultrasonographyforevaluatingbreastmasses
AT hongseongsook reproducibilityanddiagnosticperformanceofthevascularindexofsuperbmicrovascularimaginginrealtimebreastultrasonographyforevaluatingbreastmasses