Cargando…

Evaluation of Diagnostic Accuracy of Magnetic Resonance Imaging in Posterior Ligamentum Complex Injury of Thoracolumbar Spine

STUDY DESIGN: Prospective diagnostic imaging study. PURPOSE: The stability of the thoracic and lumbar spine depends significantly on the posterior ligamentum complex (PLC). Therefore, it is essential to diagnose PLC injuries accurately before deciding on a treatment plan for thoracolumbar injury pat...

Descripción completa

Detalles Bibliográficos
Autores principales: Mehta, Gaurav, Shetty, Utsav Chandrashekar, Meena, Dharamraj, Tiwari, Ashok Kumar, Nama, Kishan Gopal, Aseri, Dharmendra
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Spine Surgery 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8217858/
https://www.ncbi.nlm.nih.gov/pubmed/32872757
http://dx.doi.org/10.31616/asj.2020.0027
_version_ 1783710678623715328
author Mehta, Gaurav
Shetty, Utsav Chandrashekar
Meena, Dharamraj
Tiwari, Ashok Kumar
Nama, Kishan Gopal
Aseri, Dharmendra
author_facet Mehta, Gaurav
Shetty, Utsav Chandrashekar
Meena, Dharamraj
Tiwari, Ashok Kumar
Nama, Kishan Gopal
Aseri, Dharmendra
author_sort Mehta, Gaurav
collection PubMed
description STUDY DESIGN: Prospective diagnostic imaging study. PURPOSE: The stability of the thoracic and lumbar spine depends significantly on the posterior ligamentum complex (PLC). Therefore, it is essential to diagnose PLC injuries accurately before deciding on a treatment plan for thoracolumbar injury patients. However, the efficacy of magnetic resonance imaging (MRI) in diagnosing PLC remains undetermined. OVERVIEW OF LITERATURE: MRI has become the ultimate tool in diagnosing spine injury cases, as previous literature suggests that it has very high sensitivity and specificity. But this is still controversial and as many surgeons rely on just MRI for selecting the patient for surgery, it becomes important to know the diagnostic accuracy of it. METHODS: Patients who sustained injuries from T1 to L3 and required posterior surgery were prospectively studied. The treating surgeon and musculoskeletal radiologist participating in the study reviewed preoperative MRI images to characterize the level(s) of injury and the integrity of the six components of the PLC. These were classified as intact, incompletely disrupted, or disrupted. During the surgical procedure, the surgeon also classified each component of the PLC, and the radiologist’s and surgeon’s findings were compared. RESULTS: Out of 66 patients, 46 were males (69.7%) and 20 were females (30.3%), and the average age was 34.12 years. According to the kappa score, there was a moderate level of agreement between the radiologist’s interpretation and the intraoperative findings for all PLC components except for the thoracolumbar fascia and ligamentum flavum for which there was a slight agreement. The sensitivity for the intact PLC components ranged from 100% (supraspinous ligament) to 66.67% (ligamentum flavum). The specificity ranged from 100% (interspinous ligament) to 52% (thoracolumbar fascia). The Spearman’s rank correlation ranged from 0.061 for the thoracolumbar fascia to 0.918 for the interspinous ligament, and the percentage agreement ranged from 81.82% (interspinous ligament to 36.36% (thoracolumbar fascia). CONCLUSIONS: The sensitivity and specificity of MRI for diagnosing injury of the PLC in this study were lower than those previously reported in the literature. The integrity of the PLC as determined by MRI should not be used in isolation to determine treatment.
format Online
Article
Text
id pubmed-8217858
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Korean Society of Spine Surgery
record_format MEDLINE/PubMed
spelling pubmed-82178582021-07-02 Evaluation of Diagnostic Accuracy of Magnetic Resonance Imaging in Posterior Ligamentum Complex Injury of Thoracolumbar Spine Mehta, Gaurav Shetty, Utsav Chandrashekar Meena, Dharamraj Tiwari, Ashok Kumar Nama, Kishan Gopal Aseri, Dharmendra Asian Spine J Clinical Study STUDY DESIGN: Prospective diagnostic imaging study. PURPOSE: The stability of the thoracic and lumbar spine depends significantly on the posterior ligamentum complex (PLC). Therefore, it is essential to diagnose PLC injuries accurately before deciding on a treatment plan for thoracolumbar injury patients. However, the efficacy of magnetic resonance imaging (MRI) in diagnosing PLC remains undetermined. OVERVIEW OF LITERATURE: MRI has become the ultimate tool in diagnosing spine injury cases, as previous literature suggests that it has very high sensitivity and specificity. But this is still controversial and as many surgeons rely on just MRI for selecting the patient for surgery, it becomes important to know the diagnostic accuracy of it. METHODS: Patients who sustained injuries from T1 to L3 and required posterior surgery were prospectively studied. The treating surgeon and musculoskeletal radiologist participating in the study reviewed preoperative MRI images to characterize the level(s) of injury and the integrity of the six components of the PLC. These were classified as intact, incompletely disrupted, or disrupted. During the surgical procedure, the surgeon also classified each component of the PLC, and the radiologist’s and surgeon’s findings were compared. RESULTS: Out of 66 patients, 46 were males (69.7%) and 20 were females (30.3%), and the average age was 34.12 years. According to the kappa score, there was a moderate level of agreement between the radiologist’s interpretation and the intraoperative findings for all PLC components except for the thoracolumbar fascia and ligamentum flavum for which there was a slight agreement. The sensitivity for the intact PLC components ranged from 100% (supraspinous ligament) to 66.67% (ligamentum flavum). The specificity ranged from 100% (interspinous ligament) to 52% (thoracolumbar fascia). The Spearman’s rank correlation ranged from 0.061 for the thoracolumbar fascia to 0.918 for the interspinous ligament, and the percentage agreement ranged from 81.82% (interspinous ligament to 36.36% (thoracolumbar fascia). CONCLUSIONS: The sensitivity and specificity of MRI for diagnosing injury of the PLC in this study were lower than those previously reported in the literature. The integrity of the PLC as determined by MRI should not be used in isolation to determine treatment. Korean Society of Spine Surgery 2021-06 2020-09-03 /pmc/articles/PMC8217858/ /pubmed/32872757 http://dx.doi.org/10.31616/asj.2020.0027 Text en Copyright © 2021 by Korean Society of Spine Surgery https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Study
Mehta, Gaurav
Shetty, Utsav Chandrashekar
Meena, Dharamraj
Tiwari, Ashok Kumar
Nama, Kishan Gopal
Aseri, Dharmendra
Evaluation of Diagnostic Accuracy of Magnetic Resonance Imaging in Posterior Ligamentum Complex Injury of Thoracolumbar Spine
title Evaluation of Diagnostic Accuracy of Magnetic Resonance Imaging in Posterior Ligamentum Complex Injury of Thoracolumbar Spine
title_full Evaluation of Diagnostic Accuracy of Magnetic Resonance Imaging in Posterior Ligamentum Complex Injury of Thoracolumbar Spine
title_fullStr Evaluation of Diagnostic Accuracy of Magnetic Resonance Imaging in Posterior Ligamentum Complex Injury of Thoracolumbar Spine
title_full_unstemmed Evaluation of Diagnostic Accuracy of Magnetic Resonance Imaging in Posterior Ligamentum Complex Injury of Thoracolumbar Spine
title_short Evaluation of Diagnostic Accuracy of Magnetic Resonance Imaging in Posterior Ligamentum Complex Injury of Thoracolumbar Spine
title_sort evaluation of diagnostic accuracy of magnetic resonance imaging in posterior ligamentum complex injury of thoracolumbar spine
topic Clinical Study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8217858/
https://www.ncbi.nlm.nih.gov/pubmed/32872757
http://dx.doi.org/10.31616/asj.2020.0027
work_keys_str_mv AT mehtagaurav evaluationofdiagnosticaccuracyofmagneticresonanceimaginginposteriorligamentumcomplexinjuryofthoracolumbarspine
AT shettyutsavchandrashekar evaluationofdiagnosticaccuracyofmagneticresonanceimaginginposteriorligamentumcomplexinjuryofthoracolumbarspine
AT meenadharamraj evaluationofdiagnosticaccuracyofmagneticresonanceimaginginposteriorligamentumcomplexinjuryofthoracolumbarspine
AT tiwariashokkumar evaluationofdiagnosticaccuracyofmagneticresonanceimaginginposteriorligamentumcomplexinjuryofthoracolumbarspine
AT namakishangopal evaluationofdiagnosticaccuracyofmagneticresonanceimaginginposteriorligamentumcomplexinjuryofthoracolumbarspine
AT aseridharmendra evaluationofdiagnosticaccuracyofmagneticresonanceimaginginposteriorligamentumcomplexinjuryofthoracolumbarspine