EANM procedural guidelines for myocardial perfusion scintigraphy using cardiac-centered gamma cameras
An increasing number of Nuclear Medicine sites in Europe are using cardiac-centered gamma cameras for myocardial perfusion scintigraphy (MPS). Three cardiac-centered gamma cameras are currently the most frequently used in Europe: the D-SPECT (Spectrum Dynamics), the Alcyone (Discovery NM 530c and Di...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8218102/ https://www.ncbi.nlm.nih.gov/pubmed/34191169 http://dx.doi.org/10.1186/s41824-019-0058-2 |
_version_ | 1783710718744330240 |
---|---|
author | Hyafil, Fabien Gimelli, Alessia Slart, Riemer H. J. A. Georgoulias, Panagiotis Rischpler, Christoph Lubberink, Mark Sciagra, Roberto Bucerius, Jan Agostini, Denis Verberne, Hein J. |
author_facet | Hyafil, Fabien Gimelli, Alessia Slart, Riemer H. J. A. Georgoulias, Panagiotis Rischpler, Christoph Lubberink, Mark Sciagra, Roberto Bucerius, Jan Agostini, Denis Verberne, Hein J. |
author_sort | Hyafil, Fabien |
collection | PubMed |
description | An increasing number of Nuclear Medicine sites in Europe are using cardiac-centered gamma cameras for myocardial perfusion scintigraphy (MPS). Three cardiac-centered gamma cameras are currently the most frequently used in Europe: the D-SPECT (Spectrum Dynamics), the Alcyone (Discovery NM 530c and Discovery NM/CT 570c; General Electric Medical Systems), and the IQ-SPECT (Siemens Healthcare). The increased myocardial count sensitivity of these three cardiac-centered systems has allowed for a decrease in the activities of radiopharmaceuticals injected to patients for myocardial perfusion imaging and, consequently, radiation exposure of patients. When setting up protocols for MPS, the overall objective should be to maintain high diagnostic accuracy of MPS, while injecting the lowest activities reasonably achievable to reduce the level of radiation exposure of patient and staff. These guidelines aim at providing recommendations for acquisition protocols and image interpretation using cardiac-centered cameras. As each imaging system has specific design and features for image acquisition and analysis, these guidelines have been separated into three sections for each gamma camera system. These recommendations have been written by the members of the Cardiovascular Committee of EANM and were based on their own experience with each of these systems and on the existing literature. |
format | Online Article Text |
id | pubmed-8218102 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-82181022021-06-24 EANM procedural guidelines for myocardial perfusion scintigraphy using cardiac-centered gamma cameras Hyafil, Fabien Gimelli, Alessia Slart, Riemer H. J. A. Georgoulias, Panagiotis Rischpler, Christoph Lubberink, Mark Sciagra, Roberto Bucerius, Jan Agostini, Denis Verberne, Hein J. Eur J Hybrid Imaging Guideline An increasing number of Nuclear Medicine sites in Europe are using cardiac-centered gamma cameras for myocardial perfusion scintigraphy (MPS). Three cardiac-centered gamma cameras are currently the most frequently used in Europe: the D-SPECT (Spectrum Dynamics), the Alcyone (Discovery NM 530c and Discovery NM/CT 570c; General Electric Medical Systems), and the IQ-SPECT (Siemens Healthcare). The increased myocardial count sensitivity of these three cardiac-centered systems has allowed for a decrease in the activities of radiopharmaceuticals injected to patients for myocardial perfusion imaging and, consequently, radiation exposure of patients. When setting up protocols for MPS, the overall objective should be to maintain high diagnostic accuracy of MPS, while injecting the lowest activities reasonably achievable to reduce the level of radiation exposure of patient and staff. These guidelines aim at providing recommendations for acquisition protocols and image interpretation using cardiac-centered cameras. As each imaging system has specific design and features for image acquisition and analysis, these guidelines have been separated into three sections for each gamma camera system. These recommendations have been written by the members of the Cardiovascular Committee of EANM and were based on their own experience with each of these systems and on the existing literature. Springer International Publishing 2019-07-02 /pmc/articles/PMC8218102/ /pubmed/34191169 http://dx.doi.org/10.1186/s41824-019-0058-2 Text en © The Author(s) 2019 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Guideline Hyafil, Fabien Gimelli, Alessia Slart, Riemer H. J. A. Georgoulias, Panagiotis Rischpler, Christoph Lubberink, Mark Sciagra, Roberto Bucerius, Jan Agostini, Denis Verberne, Hein J. EANM procedural guidelines for myocardial perfusion scintigraphy using cardiac-centered gamma cameras |
title | EANM procedural guidelines for myocardial perfusion scintigraphy using cardiac-centered gamma cameras |
title_full | EANM procedural guidelines for myocardial perfusion scintigraphy using cardiac-centered gamma cameras |
title_fullStr | EANM procedural guidelines for myocardial perfusion scintigraphy using cardiac-centered gamma cameras |
title_full_unstemmed | EANM procedural guidelines for myocardial perfusion scintigraphy using cardiac-centered gamma cameras |
title_short | EANM procedural guidelines for myocardial perfusion scintigraphy using cardiac-centered gamma cameras |
title_sort | eanm procedural guidelines for myocardial perfusion scintigraphy using cardiac-centered gamma cameras |
topic | Guideline |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8218102/ https://www.ncbi.nlm.nih.gov/pubmed/34191169 http://dx.doi.org/10.1186/s41824-019-0058-2 |
work_keys_str_mv | AT hyafilfabien eanmproceduralguidelinesformyocardialperfusionscintigraphyusingcardiaccenteredgammacameras AT gimellialessia eanmproceduralguidelinesformyocardialperfusionscintigraphyusingcardiaccenteredgammacameras AT slartriemerhja eanmproceduralguidelinesformyocardialperfusionscintigraphyusingcardiaccenteredgammacameras AT georgouliaspanagiotis eanmproceduralguidelinesformyocardialperfusionscintigraphyusingcardiaccenteredgammacameras AT rischplerchristoph eanmproceduralguidelinesformyocardialperfusionscintigraphyusingcardiaccenteredgammacameras AT lubberinkmark eanmproceduralguidelinesformyocardialperfusionscintigraphyusingcardiaccenteredgammacameras AT sciagraroberto eanmproceduralguidelinesformyocardialperfusionscintigraphyusingcardiaccenteredgammacameras AT buceriusjan eanmproceduralguidelinesformyocardialperfusionscintigraphyusingcardiaccenteredgammacameras AT agostinidenis eanmproceduralguidelinesformyocardialperfusionscintigraphyusingcardiaccenteredgammacameras AT verberneheinj eanmproceduralguidelinesformyocardialperfusionscintigraphyusingcardiaccenteredgammacameras AT eanmproceduralguidelinesformyocardialperfusionscintigraphyusingcardiaccenteredgammacameras |