Ultraviolet C lamps for disinfection of surfaces potentially contaminated with SARS-CoV-2 in critical hospital settings: examples of their use and some practical advice

BACKGROUND: UltraViolet-C (UV-C) lamps may be used to supplement current hospital cleaning and disinfection of surfaces contaminated by SARS-CoV-2. Our aim is to provide some practical indications for the correct use of UV-C lamps. METHODS: We studied three UV-C lamps, measuring their spatial irradi...

Descripción completa

Detalles Bibliográficos
Autores principales: Lualdi, Manuela, Cavalleri, Adalberto, Bianco, Andrea, Biasin, Mara, Cavatorta, Claudia, Clerici, Mario, Galli, Paola, Pareschi, Giovanni, Pignoli, Emanuele
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8218289/
https://www.ncbi.nlm.nih.gov/pubmed/34157967
http://dx.doi.org/10.1186/s12879-021-06310-5
_version_ 1783710736441147392
author Lualdi, Manuela
Cavalleri, Adalberto
Bianco, Andrea
Biasin, Mara
Cavatorta, Claudia
Clerici, Mario
Galli, Paola
Pareschi, Giovanni
Pignoli, Emanuele
author_facet Lualdi, Manuela
Cavalleri, Adalberto
Bianco, Andrea
Biasin, Mara
Cavatorta, Claudia
Clerici, Mario
Galli, Paola
Pareschi, Giovanni
Pignoli, Emanuele
author_sort Lualdi, Manuela
collection PubMed
description BACKGROUND: UltraViolet-C (UV-C) lamps may be used to supplement current hospital cleaning and disinfection of surfaces contaminated by SARS-CoV-2. Our aim is to provide some practical indications for the correct use of UV-C lamps. METHODS: We studied three UV-C lamps, measuring their spatial irradiance and emission over time. We quantify the error that is committed by calculating the irradiation time based exclusively on the technical data of the lamps or by making direct irradiance measurements. Finally, we tested specific dosimeters for UV-C. RESULTS: Our results show that the spatial emission of UV-C lamps is strongly dependent on the power of the lamps and on the design of their reflectors. Only by optimizing the positioning and calculating the exposure time correctly, is it possible to dispense the dose necessary to obtain SARS-CoV-2 inactivation. In the absence of suitable equipment for measuring irradiance, the calculated irradiation time can be underestimated. We therefore consider it precautionary to increase the calculated times by at least 20%. CONCLUSION: To use UV-C lamps effectively, it is necessary to follow a few simple precepts when choosing, positioning and verifying the lamps. In the absence of instruments dedicated to direct verification of irradiance, photochromic UV-C dosimeters may represent a useful tool for easily verifying that a proper UV-C dose has been delivered.
format Online
Article
Text
id pubmed-8218289
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-82182892021-06-23 Ultraviolet C lamps for disinfection of surfaces potentially contaminated with SARS-CoV-2 in critical hospital settings: examples of their use and some practical advice Lualdi, Manuela Cavalleri, Adalberto Bianco, Andrea Biasin, Mara Cavatorta, Claudia Clerici, Mario Galli, Paola Pareschi, Giovanni Pignoli, Emanuele BMC Infect Dis Research BACKGROUND: UltraViolet-C (UV-C) lamps may be used to supplement current hospital cleaning and disinfection of surfaces contaminated by SARS-CoV-2. Our aim is to provide some practical indications for the correct use of UV-C lamps. METHODS: We studied three UV-C lamps, measuring their spatial irradiance and emission over time. We quantify the error that is committed by calculating the irradiation time based exclusively on the technical data of the lamps or by making direct irradiance measurements. Finally, we tested specific dosimeters for UV-C. RESULTS: Our results show that the spatial emission of UV-C lamps is strongly dependent on the power of the lamps and on the design of their reflectors. Only by optimizing the positioning and calculating the exposure time correctly, is it possible to dispense the dose necessary to obtain SARS-CoV-2 inactivation. In the absence of suitable equipment for measuring irradiance, the calculated irradiation time can be underestimated. We therefore consider it precautionary to increase the calculated times by at least 20%. CONCLUSION: To use UV-C lamps effectively, it is necessary to follow a few simple precepts when choosing, positioning and verifying the lamps. In the absence of instruments dedicated to direct verification of irradiance, photochromic UV-C dosimeters may represent a useful tool for easily verifying that a proper UV-C dose has been delivered. BioMed Central 2021-06-22 /pmc/articles/PMC8218289/ /pubmed/34157967 http://dx.doi.org/10.1186/s12879-021-06310-5 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Lualdi, Manuela
Cavalleri, Adalberto
Bianco, Andrea
Biasin, Mara
Cavatorta, Claudia
Clerici, Mario
Galli, Paola
Pareschi, Giovanni
Pignoli, Emanuele
Ultraviolet C lamps for disinfection of surfaces potentially contaminated with SARS-CoV-2 in critical hospital settings: examples of their use and some practical advice
title Ultraviolet C lamps for disinfection of surfaces potentially contaminated with SARS-CoV-2 in critical hospital settings: examples of their use and some practical advice
title_full Ultraviolet C lamps for disinfection of surfaces potentially contaminated with SARS-CoV-2 in critical hospital settings: examples of their use and some practical advice
title_fullStr Ultraviolet C lamps for disinfection of surfaces potentially contaminated with SARS-CoV-2 in critical hospital settings: examples of their use and some practical advice
title_full_unstemmed Ultraviolet C lamps for disinfection of surfaces potentially contaminated with SARS-CoV-2 in critical hospital settings: examples of their use and some practical advice
title_short Ultraviolet C lamps for disinfection of surfaces potentially contaminated with SARS-CoV-2 in critical hospital settings: examples of their use and some practical advice
title_sort ultraviolet c lamps for disinfection of surfaces potentially contaminated with sars-cov-2 in critical hospital settings: examples of their use and some practical advice
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8218289/
https://www.ncbi.nlm.nih.gov/pubmed/34157967
http://dx.doi.org/10.1186/s12879-021-06310-5
work_keys_str_mv AT lualdimanuela ultravioletclampsfordisinfectionofsurfacespotentiallycontaminatedwithsarscov2incriticalhospitalsettingsexamplesoftheiruseandsomepracticaladvice
AT cavalleriadalberto ultravioletclampsfordisinfectionofsurfacespotentiallycontaminatedwithsarscov2incriticalhospitalsettingsexamplesoftheiruseandsomepracticaladvice
AT biancoandrea ultravioletclampsfordisinfectionofsurfacespotentiallycontaminatedwithsarscov2incriticalhospitalsettingsexamplesoftheiruseandsomepracticaladvice
AT biasinmara ultravioletclampsfordisinfectionofsurfacespotentiallycontaminatedwithsarscov2incriticalhospitalsettingsexamplesoftheiruseandsomepracticaladvice
AT cavatortaclaudia ultravioletclampsfordisinfectionofsurfacespotentiallycontaminatedwithsarscov2incriticalhospitalsettingsexamplesoftheiruseandsomepracticaladvice
AT clericimario ultravioletclampsfordisinfectionofsurfacespotentiallycontaminatedwithsarscov2incriticalhospitalsettingsexamplesoftheiruseandsomepracticaladvice
AT gallipaola ultravioletclampsfordisinfectionofsurfacespotentiallycontaminatedwithsarscov2incriticalhospitalsettingsexamplesoftheiruseandsomepracticaladvice
AT pareschigiovanni ultravioletclampsfordisinfectionofsurfacespotentiallycontaminatedwithsarscov2incriticalhospitalsettingsexamplesoftheiruseandsomepracticaladvice
AT pignoliemanuele ultravioletclampsfordisinfectionofsurfacespotentiallycontaminatedwithsarscov2incriticalhospitalsettingsexamplesoftheiruseandsomepracticaladvice