Cargando…
Application of a targeted and quantificational foraminoplasty device in percutaneous transforaminal endoscopic discectomy for L5–S1 disc herniation: preliminary clinical outcomes
OBJECTIVE: Percutaneous transforaminal endoscopic discectomy (PTED) is minimally invasive and has been widely used to treat patients with lumbar disc herniation (LDH) due to its safety and efficiency. However, due to the unique anatomy of the L5–S1 level, the PTED procedure is often difficult to per...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8218444/ https://www.ncbi.nlm.nih.gov/pubmed/34158087 http://dx.doi.org/10.1186/s13018-021-02533-z |
_version_ | 1783710766107459584 |
---|---|
author | Liu, Jinlong Wu, Junlong Zhang, Honglei Zuo, Rui Liu, Jiabin Zhang, Chao |
author_facet | Liu, Jinlong Wu, Junlong Zhang, Honglei Zuo, Rui Liu, Jiabin Zhang, Chao |
author_sort | Liu, Jinlong |
collection | PubMed |
description | OBJECTIVE: Percutaneous transforaminal endoscopic discectomy (PTED) is minimally invasive and has been widely used to treat patients with lumbar disc herniation (LDH) due to its safety and efficiency. However, due to the unique anatomy of the L5–S1 level, the PTED procedure is often difficult to perform in the region. ZESSYS, a targeted and quantificational foraminoplasty device, may help to overcome these anatomical limitations. In this study, we assessed the efficiency and the short-term effects of PTED with ZESSYS at the L5–S1 level. METHODS: Between January and August of 2018, fifty-six patients with lumbar disc herniation at the single level of L5–S1 and who underwent percutaneous transforaminal endoscopic discectomy were enrolled in this retrospective cohort study. They were segregated into the transforaminal endoscopic surgical system (TESSYS) group and the ZESSYS group. The puncture time, foraminoplasty time, decompression time, and fluoroscopy time were evaluated for operation efficiency. Clinical outcomes were assessed by the visual analog scale (VAS) score and Oswestry Disability Index (ODI) score. The MacNab criteria were used to evaluate patient subjective satisfaction at 12-month follow-up postoperatively. RESULTS: The average puncture time (5.29 ± 2.05 min), foraminoplasty time (12.82 ± 2.52 min), and fluoroscopy time (26.29 ± 5.96 s) were all significantly shorter in the ZESSYS group than in the TESSYS group (average puncture time 8.07 ± 3.13 min, p < 0.01; foraminoplasty time, 17.18 ± 2.92 min, p < 0.01; fluoroscopy time, 34.73 ± 6.86 s; p < 0.01). No significant differences were observed between the 2 groups in the decompression time (p = 0.057). The VAS score of low back pain and leg pain, as well as the ODI score, improved at all time points postoperatively compared with preoperative, in both the TESSYS group and the ZESSYS group (P < 0.05). There were no significant differences in the VAS score of low back pain, VAS score of leg pain, and ODI score between the TESSYS group and the ZESSYS group at the same time points (P > 0.05). According to the MacNab criteria, the excellent and good rate at 12-month follow-up postoperatively was 85.7% in the TESSYS group and 89.3% in the ZESSYS group (P > 0.05). CONCLUSION: The targeted and quantificational foraminoplasty device named ZESSYS was more efficient in the puncture and foraminoplasty procedures, effectively protecting the exiting nerve and minimizing the level of radiation exposure. The device is efficient and safe for PTED in treating lumbar disc herniation at the L5–S1 level. |
format | Online Article Text |
id | pubmed-8218444 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-82184442021-06-23 Application of a targeted and quantificational foraminoplasty device in percutaneous transforaminal endoscopic discectomy for L5–S1 disc herniation: preliminary clinical outcomes Liu, Jinlong Wu, Junlong Zhang, Honglei Zuo, Rui Liu, Jiabin Zhang, Chao J Orthop Surg Res Research Article OBJECTIVE: Percutaneous transforaminal endoscopic discectomy (PTED) is minimally invasive and has been widely used to treat patients with lumbar disc herniation (LDH) due to its safety and efficiency. However, due to the unique anatomy of the L5–S1 level, the PTED procedure is often difficult to perform in the region. ZESSYS, a targeted and quantificational foraminoplasty device, may help to overcome these anatomical limitations. In this study, we assessed the efficiency and the short-term effects of PTED with ZESSYS at the L5–S1 level. METHODS: Between January and August of 2018, fifty-six patients with lumbar disc herniation at the single level of L5–S1 and who underwent percutaneous transforaminal endoscopic discectomy were enrolled in this retrospective cohort study. They were segregated into the transforaminal endoscopic surgical system (TESSYS) group and the ZESSYS group. The puncture time, foraminoplasty time, decompression time, and fluoroscopy time were evaluated for operation efficiency. Clinical outcomes were assessed by the visual analog scale (VAS) score and Oswestry Disability Index (ODI) score. The MacNab criteria were used to evaluate patient subjective satisfaction at 12-month follow-up postoperatively. RESULTS: The average puncture time (5.29 ± 2.05 min), foraminoplasty time (12.82 ± 2.52 min), and fluoroscopy time (26.29 ± 5.96 s) were all significantly shorter in the ZESSYS group than in the TESSYS group (average puncture time 8.07 ± 3.13 min, p < 0.01; foraminoplasty time, 17.18 ± 2.92 min, p < 0.01; fluoroscopy time, 34.73 ± 6.86 s; p < 0.01). No significant differences were observed between the 2 groups in the decompression time (p = 0.057). The VAS score of low back pain and leg pain, as well as the ODI score, improved at all time points postoperatively compared with preoperative, in both the TESSYS group and the ZESSYS group (P < 0.05). There were no significant differences in the VAS score of low back pain, VAS score of leg pain, and ODI score between the TESSYS group and the ZESSYS group at the same time points (P > 0.05). According to the MacNab criteria, the excellent and good rate at 12-month follow-up postoperatively was 85.7% in the TESSYS group and 89.3% in the ZESSYS group (P > 0.05). CONCLUSION: The targeted and quantificational foraminoplasty device named ZESSYS was more efficient in the puncture and foraminoplasty procedures, effectively protecting the exiting nerve and minimizing the level of radiation exposure. The device is efficient and safe for PTED in treating lumbar disc herniation at the L5–S1 level. BioMed Central 2021-06-22 /pmc/articles/PMC8218444/ /pubmed/34158087 http://dx.doi.org/10.1186/s13018-021-02533-z Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Liu, Jinlong Wu, Junlong Zhang, Honglei Zuo, Rui Liu, Jiabin Zhang, Chao Application of a targeted and quantificational foraminoplasty device in percutaneous transforaminal endoscopic discectomy for L5–S1 disc herniation: preliminary clinical outcomes |
title | Application of a targeted and quantificational foraminoplasty device in percutaneous transforaminal endoscopic discectomy for L5–S1 disc herniation: preliminary clinical outcomes |
title_full | Application of a targeted and quantificational foraminoplasty device in percutaneous transforaminal endoscopic discectomy for L5–S1 disc herniation: preliminary clinical outcomes |
title_fullStr | Application of a targeted and quantificational foraminoplasty device in percutaneous transforaminal endoscopic discectomy for L5–S1 disc herniation: preliminary clinical outcomes |
title_full_unstemmed | Application of a targeted and quantificational foraminoplasty device in percutaneous transforaminal endoscopic discectomy for L5–S1 disc herniation: preliminary clinical outcomes |
title_short | Application of a targeted and quantificational foraminoplasty device in percutaneous transforaminal endoscopic discectomy for L5–S1 disc herniation: preliminary clinical outcomes |
title_sort | application of a targeted and quantificational foraminoplasty device in percutaneous transforaminal endoscopic discectomy for l5–s1 disc herniation: preliminary clinical outcomes |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8218444/ https://www.ncbi.nlm.nih.gov/pubmed/34158087 http://dx.doi.org/10.1186/s13018-021-02533-z |
work_keys_str_mv | AT liujinlong applicationofatargetedandquantificationalforaminoplastydeviceinpercutaneoustransforaminalendoscopicdiscectomyforl5s1discherniationpreliminaryclinicaloutcomes AT wujunlong applicationofatargetedandquantificationalforaminoplastydeviceinpercutaneoustransforaminalendoscopicdiscectomyforl5s1discherniationpreliminaryclinicaloutcomes AT zhanghonglei applicationofatargetedandquantificationalforaminoplastydeviceinpercutaneoustransforaminalendoscopicdiscectomyforl5s1discherniationpreliminaryclinicaloutcomes AT zuorui applicationofatargetedandquantificationalforaminoplastydeviceinpercutaneoustransforaminalendoscopicdiscectomyforl5s1discherniationpreliminaryclinicaloutcomes AT liujiabin applicationofatargetedandquantificationalforaminoplastydeviceinpercutaneoustransforaminalendoscopicdiscectomyforl5s1discherniationpreliminaryclinicaloutcomes AT zhangchao applicationofatargetedandquantificationalforaminoplastydeviceinpercutaneoustransforaminalendoscopicdiscectomyforl5s1discherniationpreliminaryclinicaloutcomes |