Cargando…

Combined Loop-Mediated Isothermal Amplification Assays for Rapid Detection and One-Step Differentiation of Campylobacter jejuni and Campylobacter coli in Meat Products

A loop-mediated isothermal amplification (LAMP) assay system was established, allowing rplD gene-based simultaneous detection of Campylobacter jejuni and Campylobacter coli in enriched meat products. Additionally, one-step differentiation of target species on agar plates was enabled by cdtC gene- an...

Descripción completa

Detalles Bibliográficos
Autores principales: Kreitlow, Antonia, Becker, André, Ahmed, Marwa F. E., Kittler, Sophie, Schotte, Ulrich, Plötz, Madeleine, Abdulmawjood, Amir
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8219907/
https://www.ncbi.nlm.nih.gov/pubmed/34177847
http://dx.doi.org/10.3389/fmicb.2021.668824
_version_ 1783711039510020096
author Kreitlow, Antonia
Becker, André
Ahmed, Marwa F. E.
Kittler, Sophie
Schotte, Ulrich
Plötz, Madeleine
Abdulmawjood, Amir
author_facet Kreitlow, Antonia
Becker, André
Ahmed, Marwa F. E.
Kittler, Sophie
Schotte, Ulrich
Plötz, Madeleine
Abdulmawjood, Amir
author_sort Kreitlow, Antonia
collection PubMed
description A loop-mediated isothermal amplification (LAMP) assay system was established, allowing rplD gene-based simultaneous detection of Campylobacter jejuni and Campylobacter coli in enriched meat products. Additionally, one-step differentiation of target species on agar plates was enabled by cdtC gene- and gyrA gene-based duplex LAMP. Both the rplD and cdtC–gyrA LAMP assays amplified the target sequences in all 62 C. jejuni and 27 C. coli strains used for determining inclusivity and revealed 100% exclusivity toward 85 tested non-target species. Throughout the entire experiments, C. jejuni and C. coli strains were 100% distinguishable by melting curves of cdtC and gyrA LAMP products. After 24-h enrichment, the rplD LAMP assay reliably detected initial inoculation levels of 10–100 CFU/g in artificially contaminated minced meat. Investigation of naturally contaminated meat samples revealed a diagnostic accuracy of 95% toward real-time PCR and 94.1% toward the standard culture method applying the 24-h incubation period. Diagnostic sensitivity and specificity, and positive and negative predictive values were 89.8, 100, 100, and 91.2%, respectively, when measured against real-time PCR, and 89.6, 98.1, 97.7, and 91.2%, respectively, when measured against the standard culture method. After 48-h enrichment, the detection limit of the rplD LAMP assay improved to initial inoculation levels of 1–10 CFU/g in artificially contaminated minced meat. Applying the 48-h incubation period on naturally contaminated meat samples resulted in 100% concordant results between rplD LAMP, real-time PCR, and the standard culture method. The established LAMP assay system was proved to be suitable for rapid meat sample screening. Furthermore, it constitutes a promising tool for investigating other Campylobacter sources and could therefore make a valuable contribution to protect consumers from foodborne illness.
format Online
Article
Text
id pubmed-8219907
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-82199072021-06-24 Combined Loop-Mediated Isothermal Amplification Assays for Rapid Detection and One-Step Differentiation of Campylobacter jejuni and Campylobacter coli in Meat Products Kreitlow, Antonia Becker, André Ahmed, Marwa F. E. Kittler, Sophie Schotte, Ulrich Plötz, Madeleine Abdulmawjood, Amir Front Microbiol Microbiology A loop-mediated isothermal amplification (LAMP) assay system was established, allowing rplD gene-based simultaneous detection of Campylobacter jejuni and Campylobacter coli in enriched meat products. Additionally, one-step differentiation of target species on agar plates was enabled by cdtC gene- and gyrA gene-based duplex LAMP. Both the rplD and cdtC–gyrA LAMP assays amplified the target sequences in all 62 C. jejuni and 27 C. coli strains used for determining inclusivity and revealed 100% exclusivity toward 85 tested non-target species. Throughout the entire experiments, C. jejuni and C. coli strains were 100% distinguishable by melting curves of cdtC and gyrA LAMP products. After 24-h enrichment, the rplD LAMP assay reliably detected initial inoculation levels of 10–100 CFU/g in artificially contaminated minced meat. Investigation of naturally contaminated meat samples revealed a diagnostic accuracy of 95% toward real-time PCR and 94.1% toward the standard culture method applying the 24-h incubation period. Diagnostic sensitivity and specificity, and positive and negative predictive values were 89.8, 100, 100, and 91.2%, respectively, when measured against real-time PCR, and 89.6, 98.1, 97.7, and 91.2%, respectively, when measured against the standard culture method. After 48-h enrichment, the detection limit of the rplD LAMP assay improved to initial inoculation levels of 1–10 CFU/g in artificially contaminated minced meat. Applying the 48-h incubation period on naturally contaminated meat samples resulted in 100% concordant results between rplD LAMP, real-time PCR, and the standard culture method. The established LAMP assay system was proved to be suitable for rapid meat sample screening. Furthermore, it constitutes a promising tool for investigating other Campylobacter sources and could therefore make a valuable contribution to protect consumers from foodborne illness. Frontiers Media S.A. 2021-06-09 /pmc/articles/PMC8219907/ /pubmed/34177847 http://dx.doi.org/10.3389/fmicb.2021.668824 Text en Copyright © 2021 Kreitlow, Becker, Ahmed, Kittler, Schotte, Plötz and Abdulmawjood. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Microbiology
Kreitlow, Antonia
Becker, André
Ahmed, Marwa F. E.
Kittler, Sophie
Schotte, Ulrich
Plötz, Madeleine
Abdulmawjood, Amir
Combined Loop-Mediated Isothermal Amplification Assays for Rapid Detection and One-Step Differentiation of Campylobacter jejuni and Campylobacter coli in Meat Products
title Combined Loop-Mediated Isothermal Amplification Assays for Rapid Detection and One-Step Differentiation of Campylobacter jejuni and Campylobacter coli in Meat Products
title_full Combined Loop-Mediated Isothermal Amplification Assays for Rapid Detection and One-Step Differentiation of Campylobacter jejuni and Campylobacter coli in Meat Products
title_fullStr Combined Loop-Mediated Isothermal Amplification Assays for Rapid Detection and One-Step Differentiation of Campylobacter jejuni and Campylobacter coli in Meat Products
title_full_unstemmed Combined Loop-Mediated Isothermal Amplification Assays for Rapid Detection and One-Step Differentiation of Campylobacter jejuni and Campylobacter coli in Meat Products
title_short Combined Loop-Mediated Isothermal Amplification Assays for Rapid Detection and One-Step Differentiation of Campylobacter jejuni and Campylobacter coli in Meat Products
title_sort combined loop-mediated isothermal amplification assays for rapid detection and one-step differentiation of campylobacter jejuni and campylobacter coli in meat products
topic Microbiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8219907/
https://www.ncbi.nlm.nih.gov/pubmed/34177847
http://dx.doi.org/10.3389/fmicb.2021.668824
work_keys_str_mv AT kreitlowantonia combinedloopmediatedisothermalamplificationassaysforrapiddetectionandonestepdifferentiationofcampylobacterjejuniandcampylobactercoliinmeatproducts
AT beckerandre combinedloopmediatedisothermalamplificationassaysforrapiddetectionandonestepdifferentiationofcampylobacterjejuniandcampylobactercoliinmeatproducts
AT ahmedmarwafe combinedloopmediatedisothermalamplificationassaysforrapiddetectionandonestepdifferentiationofcampylobacterjejuniandcampylobactercoliinmeatproducts
AT kittlersophie combinedloopmediatedisothermalamplificationassaysforrapiddetectionandonestepdifferentiationofcampylobacterjejuniandcampylobactercoliinmeatproducts
AT schotteulrich combinedloopmediatedisothermalamplificationassaysforrapiddetectionandonestepdifferentiationofcampylobacterjejuniandcampylobactercoliinmeatproducts
AT plotzmadeleine combinedloopmediatedisothermalamplificationassaysforrapiddetectionandonestepdifferentiationofcampylobacterjejuniandcampylobactercoliinmeatproducts
AT abdulmawjoodamir combinedloopmediatedisothermalamplificationassaysforrapiddetectionandonestepdifferentiationofcampylobacterjejuniandcampylobactercoliinmeatproducts