Cargando…

Measures of excess [Formula: see text] CO(2) and recovery [Formula: see text] CO(2) as indices of performance fatigability during exercise: a pilot study

BACKGROUND: The severity of performance fatigability and the capacity to recover from activity are profoundly influenced by skeletal muscle energetics, specifically the ability to buffer fatigue-inducing ions produced from anaerobic metabolism. Mechanisms responsible for buffering these ions result...

Descripción completa

Detalles Bibliográficos
Autores principales: Wooten, Liana C., Neville, Brian T., Keyser, Randall E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8220798/
https://www.ncbi.nlm.nih.gov/pubmed/34162443
http://dx.doi.org/10.1186/s40814-021-00840-0
_version_ 1783711216805347328
author Wooten, Liana C.
Neville, Brian T.
Keyser, Randall E.
author_facet Wooten, Liana C.
Neville, Brian T.
Keyser, Randall E.
author_sort Wooten, Liana C.
collection PubMed
description BACKGROUND: The severity of performance fatigability and the capacity to recover from activity are profoundly influenced by skeletal muscle energetics, specifically the ability to buffer fatigue-inducing ions produced from anaerobic metabolism. Mechanisms responsible for buffering these ions result in the production of excess carbon dioxide (CO(2)) that can be measured as expired CO(2) ([Formula: see text] CO(2)) during cardiopulmonary exercise testing (CPET). The primary objective of this study was to assess the feasibility of select assessment procedures for use in planning and carrying out interventional studies, which are larger interventional studies investigating the relationships between CO(2) expiration, measured during and after both CPET and submaximal exercise testing, and performance fatigability. METHODS: Cross-sectional, pilot study design. Seven healthy subjects (30.7±5.1 years; 5 females) completed a peak CPET and constant work-rate test (CWRT) on separate days, each followed by a 10-min recovery then 10-min walk test. Oxygen consumption ([Formula: see text] O(2)) and [Formula: see text] CO(2) on- and off-kinetics (transition constant and oxidative response index), excess-[Formula: see text] CO(2), and performance fatigability severity scores (PFSS) were measured. Data were analyzed using regression analyses. RESULTS: All subjects that met the inclusion/exclusion criteria and consented to participate in the study completed all exercise testing sessions with no adverse events. All testing procedures were carried out successfully and outcome measures were obtained, as intended, without adverse events. Excess-[Formula: see text] CO(2) accounted for 61% of the variability in performance fatigability as measured by [Formula: see text] O(2) on-kinetic ORI (ml/s) (R(2)=0.614; y = 8.474x − 4.379, 95% CI [0.748, 16.200]) and 62% of the variability as measured by PFSS (R(2)=0.619; y =  − 0.096x + 1.267, 95% CI [−0.183, −0.009]). During CPET, [Formula: see text] CO(2) -off ORI accounted for 70% (R(2)=0.695; y = 1.390x − 11.984, 95% CI [0.331, 2.449]) and [Formula: see text] CO(2) -off Kt for 73% of the variability in performance fatigability measured by [Formula: see text] O(2) on-kinetic ORI (ml/s) (R(2)=0.730; y = 1.818x − 13.639, 95% CI [0.548, 3.087]). CONCLUSION: The findings of this study suggest that utilizing [Formula: see text] CO(2) measures may be a viable and useful addition or alternative to [Formula: see text] O(2) measures, warranting further study. While the current protocol appeared to be satisfactory, for obtaining select cardiopulmonary and performance fatigability measures as intended, modifications to the current protocol to consider in subsequent, larger studies may include use of an alternate mode or measure to enable control of work rate constancy during performance fatigability testing following initial CPET.
format Online
Article
Text
id pubmed-8220798
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-82207982021-06-24 Measures of excess [Formula: see text] CO(2) and recovery [Formula: see text] CO(2) as indices of performance fatigability during exercise: a pilot study Wooten, Liana C. Neville, Brian T. Keyser, Randall E. Pilot Feasibility Stud Research BACKGROUND: The severity of performance fatigability and the capacity to recover from activity are profoundly influenced by skeletal muscle energetics, specifically the ability to buffer fatigue-inducing ions produced from anaerobic metabolism. Mechanisms responsible for buffering these ions result in the production of excess carbon dioxide (CO(2)) that can be measured as expired CO(2) ([Formula: see text] CO(2)) during cardiopulmonary exercise testing (CPET). The primary objective of this study was to assess the feasibility of select assessment procedures for use in planning and carrying out interventional studies, which are larger interventional studies investigating the relationships between CO(2) expiration, measured during and after both CPET and submaximal exercise testing, and performance fatigability. METHODS: Cross-sectional, pilot study design. Seven healthy subjects (30.7±5.1 years; 5 females) completed a peak CPET and constant work-rate test (CWRT) on separate days, each followed by a 10-min recovery then 10-min walk test. Oxygen consumption ([Formula: see text] O(2)) and [Formula: see text] CO(2) on- and off-kinetics (transition constant and oxidative response index), excess-[Formula: see text] CO(2), and performance fatigability severity scores (PFSS) were measured. Data were analyzed using regression analyses. RESULTS: All subjects that met the inclusion/exclusion criteria and consented to participate in the study completed all exercise testing sessions with no adverse events. All testing procedures were carried out successfully and outcome measures were obtained, as intended, without adverse events. Excess-[Formula: see text] CO(2) accounted for 61% of the variability in performance fatigability as measured by [Formula: see text] O(2) on-kinetic ORI (ml/s) (R(2)=0.614; y = 8.474x − 4.379, 95% CI [0.748, 16.200]) and 62% of the variability as measured by PFSS (R(2)=0.619; y =  − 0.096x + 1.267, 95% CI [−0.183, −0.009]). During CPET, [Formula: see text] CO(2) -off ORI accounted for 70% (R(2)=0.695; y = 1.390x − 11.984, 95% CI [0.331, 2.449]) and [Formula: see text] CO(2) -off Kt for 73% of the variability in performance fatigability measured by [Formula: see text] O(2) on-kinetic ORI (ml/s) (R(2)=0.730; y = 1.818x − 13.639, 95% CI [0.548, 3.087]). CONCLUSION: The findings of this study suggest that utilizing [Formula: see text] CO(2) measures may be a viable and useful addition or alternative to [Formula: see text] O(2) measures, warranting further study. While the current protocol appeared to be satisfactory, for obtaining select cardiopulmonary and performance fatigability measures as intended, modifications to the current protocol to consider in subsequent, larger studies may include use of an alternate mode or measure to enable control of work rate constancy during performance fatigability testing following initial CPET. BioMed Central 2021-06-23 /pmc/articles/PMC8220798/ /pubmed/34162443 http://dx.doi.org/10.1186/s40814-021-00840-0 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Wooten, Liana C.
Neville, Brian T.
Keyser, Randall E.
Measures of excess [Formula: see text] CO(2) and recovery [Formula: see text] CO(2) as indices of performance fatigability during exercise: a pilot study
title Measures of excess [Formula: see text] CO(2) and recovery [Formula: see text] CO(2) as indices of performance fatigability during exercise: a pilot study
title_full Measures of excess [Formula: see text] CO(2) and recovery [Formula: see text] CO(2) as indices of performance fatigability during exercise: a pilot study
title_fullStr Measures of excess [Formula: see text] CO(2) and recovery [Formula: see text] CO(2) as indices of performance fatigability during exercise: a pilot study
title_full_unstemmed Measures of excess [Formula: see text] CO(2) and recovery [Formula: see text] CO(2) as indices of performance fatigability during exercise: a pilot study
title_short Measures of excess [Formula: see text] CO(2) and recovery [Formula: see text] CO(2) as indices of performance fatigability during exercise: a pilot study
title_sort measures of excess [formula: see text] co(2) and recovery [formula: see text] co(2) as indices of performance fatigability during exercise: a pilot study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8220798/
https://www.ncbi.nlm.nih.gov/pubmed/34162443
http://dx.doi.org/10.1186/s40814-021-00840-0
work_keys_str_mv AT wootenlianac measuresofexcessformulaseetextco2andrecoveryformulaseetextco2asindicesofperformancefatigabilityduringexerciseapilotstudy
AT nevillebriant measuresofexcessformulaseetextco2andrecoveryformulaseetextco2asindicesofperformancefatigabilityduringexerciseapilotstudy
AT keyserrandalle measuresofexcessformulaseetextco2andrecoveryformulaseetextco2asindicesofperformancefatigabilityduringexerciseapilotstudy