Cargando…
Multiplexed droplet loop-mediated isothermal amplification with scorpion-shaped probes and fluorescence microscopic counting for digital quantification of virus RNAs
Highly sensitive digital nucleic acid techniques are of great significance for the prevention and control of epidemic diseases. Here we report the development of multiplexed droplet loop-mediated isothermal amplification (multiplexed dLAMP) with scorpion-shaped probes (SPs) and fluorescence microsco...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Royal Society of Chemistry
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8221175/ https://www.ncbi.nlm.nih.gov/pubmed/34221326 http://dx.doi.org/10.1039/d1sc00616a |
_version_ | 1783711282469273600 |
---|---|
author | Tan, Ya-Ling Huang, A-Qian Tang, Li-Juan Jiang, Jian-Hui |
author_facet | Tan, Ya-Ling Huang, A-Qian Tang, Li-Juan Jiang, Jian-Hui |
author_sort | Tan, Ya-Ling |
collection | PubMed |
description | Highly sensitive digital nucleic acid techniques are of great significance for the prevention and control of epidemic diseases. Here we report the development of multiplexed droplet loop-mediated isothermal amplification (multiplexed dLAMP) with scorpion-shaped probes (SPs) and fluorescence microscopic counting for simultaneous quantification of multiple targets. A set of target-specific fluorescence-activable SPs are designed, which allows establishment of a novel multiplexed LAMP strategy for simultaneous detection of multiple cDNA targets. The digital multiplexed LAMP assay is thus developed by implementing the LAMP reaction using a droplet microfluidic chip coupled to a droplet counting microwell chip. The droplet counting system allows rapid and accurate counting of the numbers of total droplets and the positive droplets by collecting multi-color fluorescence images of the droplets in a microwell. The multiplexed dLAMP assay was successfully demonstrated for the quantification of HCV and HIV cDNA with high precision and detection limits as low as 4 copies per reaction. We also verified its potential for simultaneous digital assay of HCV and HIV RNA in clinical plasma samples. This multiplexed dLAMP technique can afford a useful platform for highly sensitive and specific detection of nucleic acids of viruses and other pathogens, enabling rapid diagnosis and prevention of infectious diseases. |
format | Online Article Text |
id | pubmed-8221175 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | The Royal Society of Chemistry |
record_format | MEDLINE/PubMed |
spelling | pubmed-82211752021-07-02 Multiplexed droplet loop-mediated isothermal amplification with scorpion-shaped probes and fluorescence microscopic counting for digital quantification of virus RNAs Tan, Ya-Ling Huang, A-Qian Tang, Li-Juan Jiang, Jian-Hui Chem Sci Chemistry Highly sensitive digital nucleic acid techniques are of great significance for the prevention and control of epidemic diseases. Here we report the development of multiplexed droplet loop-mediated isothermal amplification (multiplexed dLAMP) with scorpion-shaped probes (SPs) and fluorescence microscopic counting for simultaneous quantification of multiple targets. A set of target-specific fluorescence-activable SPs are designed, which allows establishment of a novel multiplexed LAMP strategy for simultaneous detection of multiple cDNA targets. The digital multiplexed LAMP assay is thus developed by implementing the LAMP reaction using a droplet microfluidic chip coupled to a droplet counting microwell chip. The droplet counting system allows rapid and accurate counting of the numbers of total droplets and the positive droplets by collecting multi-color fluorescence images of the droplets in a microwell. The multiplexed dLAMP assay was successfully demonstrated for the quantification of HCV and HIV cDNA with high precision and detection limits as low as 4 copies per reaction. We also verified its potential for simultaneous digital assay of HCV and HIV RNA in clinical plasma samples. This multiplexed dLAMP technique can afford a useful platform for highly sensitive and specific detection of nucleic acids of viruses and other pathogens, enabling rapid diagnosis and prevention of infectious diseases. The Royal Society of Chemistry 2021-05-14 /pmc/articles/PMC8221175/ /pubmed/34221326 http://dx.doi.org/10.1039/d1sc00616a Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by-nc/3.0/ |
spellingShingle | Chemistry Tan, Ya-Ling Huang, A-Qian Tang, Li-Juan Jiang, Jian-Hui Multiplexed droplet loop-mediated isothermal amplification with scorpion-shaped probes and fluorescence microscopic counting for digital quantification of virus RNAs |
title | Multiplexed droplet loop-mediated isothermal amplification with scorpion-shaped probes and fluorescence microscopic counting for digital quantification of virus RNAs |
title_full | Multiplexed droplet loop-mediated isothermal amplification with scorpion-shaped probes and fluorescence microscopic counting for digital quantification of virus RNAs |
title_fullStr | Multiplexed droplet loop-mediated isothermal amplification with scorpion-shaped probes and fluorescence microscopic counting for digital quantification of virus RNAs |
title_full_unstemmed | Multiplexed droplet loop-mediated isothermal amplification with scorpion-shaped probes and fluorescence microscopic counting for digital quantification of virus RNAs |
title_short | Multiplexed droplet loop-mediated isothermal amplification with scorpion-shaped probes and fluorescence microscopic counting for digital quantification of virus RNAs |
title_sort | multiplexed droplet loop-mediated isothermal amplification with scorpion-shaped probes and fluorescence microscopic counting for digital quantification of virus rnas |
topic | Chemistry |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8221175/ https://www.ncbi.nlm.nih.gov/pubmed/34221326 http://dx.doi.org/10.1039/d1sc00616a |
work_keys_str_mv | AT tanyaling multiplexeddropletloopmediatedisothermalamplificationwithscorpionshapedprobesandfluorescencemicroscopiccountingfordigitalquantificationofvirusrnas AT huangaqian multiplexeddropletloopmediatedisothermalamplificationwithscorpionshapedprobesandfluorescencemicroscopiccountingfordigitalquantificationofvirusrnas AT tanglijuan multiplexeddropletloopmediatedisothermalamplificationwithscorpionshapedprobesandfluorescencemicroscopiccountingfordigitalquantificationofvirusrnas AT jiangjianhui multiplexeddropletloopmediatedisothermalamplificationwithscorpionshapedprobesandfluorescencemicroscopiccountingfordigitalquantificationofvirusrnas |